Specications
Model PF3A703H PF3A706H PF3A712H
Fluid Applicable uid*1Air, Nitrogen
Fluid temperature 0 to 50°C
Flow
Detection method Thermal type
Rated ow range 30 to 3000 L/min 60 to 6000 L/min 120 to 12000 L/min
Set point range*2
Instantaneous ow
30 to 3150 L/min 60 to 6300 L/min 120 to 12600 L/min
Accumulated ow
0 to 999,999,999,990 L 0 to 999,999,999,900 L
Smallest settable
increment
Instantaneous ow
2 L/min 5 L/min 10 L/min
Accumulated ow
10 L 100 L
Accumulated volume per pulse
(Pulse width = 50 ms)
Select from 100 L/pulse or 1000 L/pulse.
Accumulated value hold function
*3Intervals of 2 or 5 minutes can be selected.
Pressure
Rated pressure range 0.1 to 1.5 MPa
Proof pressure 2.25 MPa
Pressure loss Refer to the “Pressure Loss” graph on page 24.
Pressure characteristics*4±2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard)
Electrical
Power supply voltage 24 VDC ±10%
Current consumption 150 mA or less
Protection Polarity protection
Accuracy
Display accuracy ±3.0% F.S.
Analog output accuracy ±3.0% F.S.
Repeatability Switch output/Display: ±1.0% F.S.
Analog output: ±1.0% F.S.
Temperature characteristics
±5.0% F.S. (Ambient temperature of 0 to 50°C, 25°C standard)
Switch output
Output type NPN open collector
PNP open collector
Output mode
Select from Instantaneous output (Hysteresis mode or Window comparator mode), Accumulated output, or Accumulated pulse output.
Switch operation Select from Normal or Reversed output.
Max. load current 80 mA
Max. applied voltage (NPN only)
28 VDC
Internal voltage drop
(Residual voltage)
NPN output type: 1 V or less (at load current of 80 mA)
PNP output type: 2 V or less (at load current of 80 mA)
Response time*5Select from 1 s, 2 s, or 5 s.
Hysteresis*6Variable from 0
Protection Over current protection
Analog output*7
Output type Voltage output: 1 to 5 V (0 to 10 V can be selected*8), Current output: 4 to 20 mA
Impedance
Voltage output
Output impedance: Approx. 1 kΩ
Current output
Maximum load impedance: Approx. 600 Ω
Response time*9Linked to the response time of the switch output
External input*10
Input type No-voltage input: 0.4 V or less
Input mode Select from Accumulated value external reset or Peak/Bottom value reset.
Input time 30 ms or longer
Display
Reference condition*11 Select from Standard conditions or Normal conditions.
Unit*12
Instantaneous ow
L/min, CFM (ft3/min)
Accumulated ow
L, ft3
Display range*13
Instantaneous ow
0 to 3150 L/min
(Flow under 30 L/min is displayed as “0”)
0 to 6300 L/min
(Flow under 60 L/min is displayed as “0”)
0 to 12600 L/min
(Flow under 120 L/min is displayed as “0”)
Accumulated ow
*14
0 to 999,999,999,990 L 0 to 999,999,999,900 L
Minimum
display unit
Instantaneous ow
2 L/min 5 L/min 10 L/min
Accumulated ow
10 L 100 L
Display
LCD, 2-screen display (Main screen/Sub screen)
Main screen: Red/Green, Sub screen: Orange
Main screen: 5 digits, 7 segment, Sub screen: 6 digits, 7 segment
Indicator LED OUT indicator: Red LED is ON when output is ON
Environmental
resistance
Enclosure IP65
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 50 MΩ(500 VDC measured via megohmmeter) between terminals and housing
Operating temperature range
Operating: 0 to 50°C, Stored: −10 to 60°C (No freezing or condensation)
Operating humidity range Operating/Stored: 35 to 85% RH (No condensation)
Standards CE marking (EMC Directive, RoHS Directive)
Piping Piping specication Rc1, NPT1, G1 Rc1 1/2, NPT1 1/2, G1 1/2 Rc2, NPT2, G2
Main materials of parts in contact with uid Aluminum alloy, PPS, HNBR [Sensor: Pt, Au, Fe, Lead glass (exempted from the RoHS application), Al2O3]
Length of lead wire with connector 3 m
Weight
Piping
specication
Rc 610 g 1190 g 1680 g
NPT 610 g 1190 g 1680 g
G630 g 1220 g 1720 g
Lead wire with connector +90 g
*1 Air quality grade is JIS B 8392-1:2012 [4:6:-] and ISO 8573-1:2010 [4:6:-].
*2
Set point range will change according to the setting of the zero cut-off function.
*3
When using the accumulated value hold function, use the operating conditions to calculate the product life,
and do not exceed it. The maximum update limit of the memory device is 1.5 million times. If the product is
operated 24 hours per day, the product life will be as follows:
·
5 min interval: life is calculated as 5 min x 1.5 million = 7.5 million min = 14.3 years
·
2 min interval: life is calculated as 2 min x 1.5 million = 3 million min = 5.7 years
If the accumulated value external reset is repeatedly used, the product life will be
shorter than the calculated life.
*4
When the pressure range is 1.0 to 1.5 MPa, the pressure characteristics will be ±5% F.S. (standard pres-
sure is 0.5 MPa). Do not release the OUT side piping port of the product to the atmosphere without con-
necting piping. If the product is used with the piping port released to atmosphere, accuracy may vary.
*5
The time from when the ow is changed by a step input (when the ow rate changes from 0 to
the maximum value of the rated ow range instantaneously) until the switch output turns ON (or
OFF) when set to be 90% of the rated ow rate
*6 If the ow uctuates around the set value, the width for setting more than the uctuating
width needs to be set. Otherwise, chattering will occur.
*7 Analog output or external input can be selected by pressing the buttons. Refer to the
graph for analog output.
*8
When selecting 0 to 10 V, refer to the analog output graph for the allowable load current.
*9 The time from when the ow is changed by a step input (when the ow rate changes
from 0 to the maximum value of the rated ow range instantaneously) until the analog
output reaches 90% of the rated ow rate
*10 Analog output or external input can be selected by pressing the buttons.
*11
The ow rate given in the specications is the value under standard conditions.
*12 Setting is only possible for models with the units selection function.
*13
Display range will change according to the setting of the zero cut-off function
.
*14 The accumulated ow display is the upper 6-digit and lower 6-digit (total of 12 digits)
display. When the upper digits are displayed, x 106lights up.
*
Products with tiny scratches, marks, or display color or brightness variations which do not
affect the performance of the product are veried as conforming products.
For ow switch precautions and specic product precautions,
refer to the “Operation Manual” on the SMC website.
14
Body Ported Type
3-Color Display Digital Flow Switch PF3A7wH Series