Snell IQGBE4000-1A Operator's manual

snellgroup.com
User Instruction Manual
IQGBE40 and IQGBE80
Ethernet Fiber Converter with 4/8 Port Switch

IQGBE Modules www.snellgroup.com
Issue 1 Rev 1 Page 2 ©2013 Snell Limited

IQGBE Modules www.snellgroup.com
Issue 1 Rev 1 Page 3 ©2013 Snell Limited
Contents
1. About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Copyright and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. IQGBE Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 Rear Panel View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4 Order Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 Feature Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.6 Technical Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.6.1 Inputs and Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.6.2 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.6.3 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.7 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.7.1 Copper Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.7.2 Fiber Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.8 SFP Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.9 Card Edge Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.10 Rear LED Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.11 Controlling the IQGBEXX from the RollCall Control Panel . . . . . . . . . . . . . . . . 15
2.11.1 Port Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.12 Port Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.13 Set Board Info Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.14 Setup Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.15 Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.15.1 Logging SFP1 (Port 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.15.2 Logging SFP2 (Port 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.15.3 Logging Misc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.16 RollCall Log Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.17 System-RollTrack Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.17.1 RollTrack Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.17.2 RollTrack Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.17.3 RollTrack Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.17.4 Using RollTracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.17.5 To configure a RollTrack action:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.17.6 Viewing RollTrack Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

IQGBE Modules www.snellgroup.com
Issue 1 Rev 1 Page 4 ©2013 Snell Limited

IQGBE Modules www.snellgroup.com About this Manual
Issue 1 Rev 1 Page 5 © 2013 Snell Limited
1. About this Manual
This manual describes the IQGBE Ethernet Fiber Converters.
If you have any questions regarding the installation and setup of your product, please refer to
the Customer Service contact details (see section 1.1).
1.1 Contact Details
Customers with a support contract should call their personalized number, which can be found
in their contract, and be ready to provide their contract number and details.
1.2 Copyright and Disclaimer
Copyright protection claimed includes all forms and matters of copyrightable material and
information now allowed by statutory or judicial law or hereinafter granted, including without
limitation, material generated from the software programs which are displayed on the screen
such as icons, screen display looks etc.
Information in this manual and software are subject to change without notice and does not
represent a commitment on the part of Snell Limited. The software described in this manual is
furnished under a license agreement and can not be reproduced or copied in any manner
without prior agreement with Snell Limited. or their authorized agents.
Reproduction or disassembly of embedded computer programs or algorithms prohibited.
No part of this publication can be transmitted or reproduced in any form or by any means,
electronic or mechanical, including photocopy, recording or any information storage and
retrieval system, without permission being granted, in writing, by the publishers or their
authorized agents.
Snell operates a policy of continuous improvement and development. Snell reserves the right
to make changes and improvements to any of the products described in this document
without prior notice.
United Kingdom (HQ)
+44 (0) 118 921 4214 (tel)
+44 (0) 118 921 4268 (fax)
customersupport@snellgroup.com
Regional Support Contacts
Snell USA
+1 818 556 2616 (tel)
+1 818 556 2626 (fax)
Snell Germany
+49 (0) 6122 98 43 0 (tel)
+49 (0) 6122 98 43 44 (fax)
Snell Spain
+34 91 446 23 07 (tel)
+34 91 446 17 74 (fax)
Snell France
+33 1 41 95 30 50 (tel)
+33 1 41 95 30 51 (fax)
Snell Asia Pacific
+852 2356 1660 (tel)
+852 2575 1690 (fax)
Snell India
+91 124 462 6000 (tel)
+91 124 437 5888 (fax)
Snell Russia
+7 499 248 3443 (tel)
+7 499 248 1104 (fax)
support.russia@snellgroup.com
Snell China
+86 10 6515 6158 (tel)
+86 10 6515 5659 (fax)
support.china@snellgroup.com

IQGBE Modules www.snellgroup.com About this Manual
Issue 1 Rev 1 Page 6 © 2013 Snell Limited

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 7 ©2013 Snell Limited
2. IQGBE Modules
2.1 Module Description
The IQGBE40/80 is a range of Gigabit Fiber Media Converter modules with either a 4 or 8
port Ethernet switch occupying either a single or double slot in an IQ modular frame. The
RJ45 copper ports are triple speed auto negotiating enabling connectivity to 10, 100 or
1000Base Ethernet devices using standard CAT5 or better cable assemblies. The fiber
interface utilizes an SFP (Small Form factor Pluggable) fiber module receptacle cage
compliant with the SFP MSA (Multi Source Agreement). It accepts a single 1000Base SFP
Fiber Transceiver with 1310nm singlemode laser transmitter and medium sensitivity receiver.
The IQGBE40/80 may be used for direct links to other fiber enabled Ethernet devices or used
as part of a system using WDM or CWDM techniques to transport multiple serial digital data
streams over a single optical cable.
2.2 Block Diagram
Fig 1. Block Diagram for IQGBE80-2A

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 8 ©2013 Snell Limited
2.3 Rear Panel View
Ethernet fiber converter with 4 port switch. 3 copper Ethernet I/O, 1 Optical I/O
Ethernet fiber converter with 8 port switch. 6 copper Ethernet I/O, 2 Optical I/O
2.4 Order Codes
Versions of the module cards available are:
Fig 2. IQGBE4000-1A, IQGBE4000-1B
Fig 3. IQGBE8000-2A, IQGBE8000-2B
SFP options
FGAN FC1-10KGB-13T 1310nm SFP Transceiver 10 km typical on 9/125 µm SMF
FGAN FC1-40KGB-13T 1310nm SFP Transceiver 55 km typical on 9/125 µm SMF
FGAN FC1-GBE-CT5 1000BASE-T Copper (RJ-45) SFP Transceiver
IQGBE4000-1A, IQGBE4000-1B Ethernet fiber converter with 4 port switch. 3 copper
Ethernet I/O, 1 Optical I/O.
IQGBE8000-2A, IQGBE8000-2B Ethernet fiber converter with 8 port switch. 6 copper
Ethernet I/O, 2 Optical I/O.
Table 1. Available Module Card Versions

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 9 ©2013 Snell Limited
2.5 Feature Summary
• 4 or 8 port Ethernet switch including fiber optic I/O
• Auto negotiation for 10/100/1000 speeds, flow control and half/full duplex modes
• Low and high power 1310 nm interfaces available
• Conforms to IEEE 802.3 wired Ethernet and fibre channel FC-PI-2 Rev. 10.0
standards
• Jumbo frame support (10k Bytes)
• MDI/MDIX auto-crossover: automatically determines whether or not cross over
between pairs is needed on copper ports
• Provides typical fiber link distances of 10 to 55 km
• Easily integrates into a CWDM system by using the 'express' channel of the
IQCWM10
• SFP status monitoring
• Front and rear of card power and port status LEDs
• Rollcall control and monitoring compatible

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 10 ©2013 Snell Limited
2.6 Technical Profile
2.6.1 Inputs and Outputs
2.6.2 Controls
Inputs and Outputs
Electrical Ethernet 3 (4 with copper SFP) IQGBE40
6 (up to 8 with copper SFPs) IQGBE80
Connector/format RJ-45, CAT 5, 6, 7 Electrical Interfaces
LC singlemode Optical Interfaces
Conforms to IEEE 802.3 Electrical Interfaces
FC-PI-2 Rev. 10.0 Optical Interfaces
Cable length Up to 100m for 1000Base-T (Electrical Interfaces)
Up to 55 km 1000Base-X, depending on SFP and cable
(Optical Interfaces)
Table 2. Inputs and Outputs
Controls
Indicators
Power OK (Green)
CPU OK (Green flashing)
Per Channel:
Link Link Up (Green)
Rate 10Mbps (Yellow), 100Mbps (Green), 1000Mbps (Blue)
RollCall Functions
Port Status Link, Speed, and Connector type
User memories Name, save and recall 16 user memories
Memory Naming User configurable naming of memories 1 - 16
Information Window Port Status
Factory Defaults Resets all of the unit's settings to their factory defaults.
Logging:
Port Logging Name
Link
Status Speed
SFP Logging Type
Status
Connector
Vendor
Vendor Part Number
Serial Number
Rx Power State
Rx Power
Tx Power State
Tx Power
Wavelength
Laser Bias
Laser Bias State
Table 3. Controls

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 11 ©2013 Snell Limited
Misc Logging Serial Number
OS Version
Build Number
Hardware Version
Uptime
Rear ID
Rear Status
Slot Width
Slot Start
Power Usage
RollTrack controls On/Off, Index, Source, Address, Command, Status, Sending
RollTrack outputs Unused
Link Down
Link Up
Speed None
Speed 10Mbps
Speed 100Mbps
Speed 1Gbps
SFP 1 Not Fitted
SFP 2 Not Fitted (IQGBE80 only)
SFP 1 Fitted
SFP 2 Fitted (IQGBE80 only)
SFP 1 RX Pwr FAIL
SFP 2 RX Pwr FAIL (IQGBE80 only)
SFP 1 RX Pwr OK
SFP 2 RX Pwr OK (IQGBE80 only)
SFP 1 TX Pwr FAIL
SFP 2 TX Pwr FAIL (IQGBE80 only)
SFP 1 TX Pwr OK
SFP 2 TX Pwr OK (IQGBE80 only)
SFP 1 TX Bias FAIL
SFP 2 TX Bias Fail (IQGBE80 only)
SFP 1 TX Bias OK
SFP 2 TX Bias OK (IQGBE80 only)
Controls
Table 3. Controls

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 12 ©2013 Snell Limited
2.6.3 Specifications
Specifications (Depends on SFP fitted)
1310 nm Standard Haul Transceiver (FGAN FC1-10KGB-13T)
Tx
Wavelength 1310 nm
Spectral width (FWHM)3 nm
Output power -9.5 dBm (min), -3 dBm max
Extinction ratio 9:1 (min)
Transmission distance 10 km* (at 0.55db/km loss, dispersion limited per
FC-PI-2 Rev.10)
*actual transmission distances depend on type of fiber, data rate and receiver sensitivity as well as other system
components.
Rx
Average Rx Sensitivity -19 dBm (max)
Optical Center
Wavelength 1265nm - 1600nm
LOS De Assert -19 dBm (max)
LOS Assert -30 dBm (min)
LOS Hysteresis 0.5 dB (min)
1310 nm Long Haul Transceiver (FGAN FC1-40KGB-13T)
Tx
Wavelength 1310 nm
Spectral width (FWHM)1 nm
Output power 0 dBm (min), +5 dBm max
Extinction ratio 9:1 (min)
Transmission distance up to 55 km* (at 0.4db/km loss, dispersion limited per
FC-PI Rev.13)
*actual transmission distances depend on type of fiber, data rate and receiver sensitivity as well as other system
components.
Rx
Average Rx Sensitivity -22 dBm (max)
Optical Center
Wavelength 1270nm - 1600nm
LOS De Assert -19 dBm (max)
LOS Assert -30 dBm (min)
LOS Hysteresis 0.5 dB (min)
Copper Interface Transceiver (FGAN FC1-GBE-CT5)
Standard IEEE 802.3 interface
Only operates at 1000Base-T
Table 4. Specifications

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 13 ©2013 Snell Limited
2.7 Connections
2.7.1 Copper Interfaces
IQGBE4000-1A/1B
10/100/1000Base-T connections to the unit are made via the RJ-45 connectors.
IQGBE8000-2A/2B
SDI inputs to the unit are made via BNC/75ohm panel jack connectors.
2.7.2 Fiber Connections
IQGBE4000-1A/1B
The rear has provision for a single SFP module.
IQGBE8000-2A/2B
The rear has provision for up to two SFP modules.
Fig 4. IQGBE4000-1A, IQGBE4000-1B Copper Connections
Fig 5. IQGBE8000-2A, IQGBE8000-2B Copper Connections
Fig 6. IQGBE4000-1A, IQGBE4000-1B Fiber Connections
Fig 7. IQGBE8000-2A, IQGBE8000-2B Fiber Connections

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 14 ©2013 Snell Limited
2.8 SFP Modules
SFP modules can provide either fiber Ethernet connectivity via LC connectors or Copper
Ethernet connectivity via RJ-45.
2.9 Card Edge Status
See Fig 9. for LED location and Table 5. for LED operation.
Fig 8. SFP Connectors
1000Base-X Fiber transceiver SFP
FGAN FC1-10KGB-13T
FGAN FC1-40KGB-13T
1000Base-T Copper Transceiver SFP
FGAN FC1-GBE-CTS
Fig 9. Card Edge LED Status
LED Description
V+ When illuminated this LED indicates that the positive power supplies are present.
CPU This led will flash to indicate that the CPU is running.
Input Channel Status (Port 1 to Port 8)
Link/Act:
Off Link is DOWN
Green Link is UP
Speed:
Off Port is not applicable to this product/SFP not fitted.
Yellow 10Mbps (e.g. 10Base-T)
Green 100Mbps (e.g. 100Base-T)
Blue 1000Mbps (e.g. 1000Base-T)
White Link is DOWN
Table 5. LED Operation

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 15 ©2013 Snell Limited
2.10 Rear LED Status
Port & power status is also provided at the rear to aid confidence indication when installing
network links.
See Fig 10. for LED location and Table 6. for LED operation.
2.11 Controlling the IQGBEXX from the RollCall Control Panel
2.11.1 Port Summary
Information about the status of the unit ports is displayed in the Port Summary section on
each RollCall Control Panel screen.
The screen shows the link status for each of the unit's ports - after headings 1-4 (IQGBE40)
or 1-8 (IQGBE80) as shown in Fig 11.-
For each port, the link status displayed will be either:-
• DOWN - link is down
• UP-10 - link is up, speed is 10Mbps
• UP-100 - link is up, speed is 100Mbps
• UP-1000 - link is up, speed is 100Mbps
Fig 10. Rear Panel LED Status
LED Description
Copper & Fiber interfaces:
Link/Act Link status is indicated by the green led being on. Activity is represented by the
LED flashing
Gb Rate When the link is operating at 1000Base-T/X the yellow LED is lit.
Power Power is OK when the green POWER LED is lit.
Table 6. Rear Panel LED Status
Fig 11. IQGBE40 & IQGBE80 RollCall Port Summary Screens
Note:
when an SFP is not fitted, that port's status will be shown in this screen as DOWN.

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 16 ©2013 Snell Limited
2.12 Port Status Screen
This screen shows the details for each port's link Status. This includes:-
• Port Name - this defaults to PORT X where "X" is the port number, alternatively, it may
be set as described in Setup Screen
• Link - this is the link status for the port, and will be displayed as either Up:XXXX or
Down.
"XXXX" indicates the connection type:
- For SFP, this can be: 1000Base-SX, 1000Base-LX, 1000Base-CX or 1000Base-T"
- For non SFP ports, this can be 10Base-T, 100Base-T or 1000Base-T
• Speed - If the link is up, this will be display according to the negotiated speed as
10Mbps, 100Mbps, 1000Mbps or if the link is down: "-"
• Connector type - This will be displayed as Copper or Fiber if an SFP is fitted or "-" if
not. The RX power is appended to the string in the case of Fiber.
This screen is present for IQGBE40 and IQGBE80.
For IQGBE40, 4 ports are shown in Fig 12.
Fig 12. IQGBE40 RollCall Port Status Screen
Note:
In Fig 12. SFP1 is not present, so that the status for Port 1 fields are shown as “-“.

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 17 ©2013 Snell Limited
For IQGBE80, 8 ports are shown in Fig 13.:
In this example, Fiber SFPs are present for Ports 1 and 5:
2.13 Set Board Info Screen
This screen allows the user to set up the Serial Number of the unit.
A new board will not have a value assigned, and the screen will appear as shown in Fig 14.
An example of Serial Number setting is shown below, where the example number
S12345678 is typed in. The user should then click the Send button (S), and then click on
Save button.
Fig 13. IQGBE80 RollCall Port Status Screen
Fig 14. IQGBE RollCall Set Board Info Screen
Fig 15. IQGBE RollCall Set Board Info Serial Number Setting

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 18 ©2013 Snell Limited
Once this is done successfully the Set Board Info screen will become invisible, and the serial
number will be set, as shown in the Setup Screen (Fig 16.):
2.14 Setup Screen
The Setup screen displays basic information about the unit. Use the functions on the screen
to restart the unit, return all settings to their factory defaults, and to change the names of the
ports.
For IQGBE40, Port1-4 Names may be edited.
Fig 16. IQGBE RollCall Setup Screen
Note:
• Until the serial number is set it will appear blank as shown in Fig 17. For details see
“Set Board Info Screen” on page 17.
Fig 17. IQGBE40 RollCall Setup Screen

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 19 ©2013 Snell Limited
For IQGBE80, Port1-8 Names may be edited:
Table 7. describes the Setup screen for the IQGBE40 (Fig 17.) and the IQGBE80 (Fig 18.)
Fig 18. IQGBE80 RollCall Setup Screen
Screen Section Description
Product: The top left part of the screen shows the various versions, options,
identifiers, etc., associated with the product's hardware, firmware and
software and also provides a means of setting controls to defaults or
restarting the unit.
Serial No.: Displays the unit serial number. See Set Board Info Screen for details on
setting this.
Restart: Use this to restart the unit, simulating a power-up/power-down cycle.
Factory Defaults: Use this to reset all of the unit's settings to their factory defaults.
Port Name 1-8 (IQGBE80) & 1-4 (IQGBE40):
The bottom half of the screen has entry fields for 8/4 Port Names. These are the Ports
displayed in logging.
To change a name, type the name in the text field and click on the Sbutton. To return the
name to its factory default, click on the Pbutton.
Table 7. Setup Screen Information

IQGBE Modules www.snellgroup.com IQGBE Modules
Issue 1 Rev 1 Page 20 ©2013 Snell Limited
2.15 Logging
Logged parameters are madeavailable to logging devices connected to the RollCall Network.
They are also displayed on a number of RollCall Screens where they can selectively be
switched off to prevent them being logged externally.
Logging Port 1 - 4
This screen shows logging for Ports 1-4. This screen is present for IQGBE40 and IQGBE80.
Logging Port 5 - 8
This screen shows logging for Ports 5-8. This screen is present for IQGBE80 only.
Fig 19. IQGBE RollCall Logging Screen Ports 1 to 4
Fig 20. IQGBE80 RollCall Logging Screen Ports 5 to 8
This manual suits for next models
3
Table of contents
Other Snell Media Converter manuals

Snell
Snell IQQMD00 Operator's manual

Snell
Snell Sirius 600 User manual

Snell
Snell Kudos LC300 User manual

Snell
Snell CVR800 User manual

Snell
Snell Kudos LC300 User manual

Snell
Snell IQMDMO User manual

Snell
Snell Mach HD Operator's manual

Snell
Snell IQMDA00 User manual

Snell
Snell Mach HD User manual

Snell
Snell IQDEC0218-2A User manual