SAFETY
CHECK.OUT
After correcting the original service problem,
perform the following safety check before releasing
the setto the customer:
Checkthe antenna terminals, metal trim, "metallized"
knobs, screws, and all other exposed metal parts for
AC leakage. Check leakage
as
describedbelow.
LEAKAGE TEST
The AC leakage
from any exposed
metal part to
earth ground and from all exposed
metal parts
to any
exposedmetal part having a return to chassis,
must
not exceed 0.5 mA (500 microampers). Leakage
current can be measured by any one of three
methods.
I . A commercial leakage tester, such as the
Simpson 229 or RCA WT-540A. Follow the
manufacturers' instructions to use these instru-
ments.
2. A battery-operated
AC milliammeter' The Data
Precision
245 digital multimeter is suitable
for
this
job.
3. Measuring
the voltage
drop across
a resistor
by
means
of a VOM or battery-operated
AC volt-
meter. The "limit" indication is 0'75V' so
analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa
SH-63Trd are examples
of a passive
VOM that
is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are
suitable. (See
Fig. A)
TA-ElOOOESD
MODEL
IDENTIFICATION
-specificationLabel-
UK
Model:
AC: 240V
- 50/60H2
E
Model:
AC:
r2Ol220/240V-50l60H2
SAFETY.RELATED
COMPONENT
WARNINGI
I
CoMPONENTS
IDENTIFIED
BY MARK I On OOrreo
L|NEW]TH
MARK a ONTHESCHEMATIC
DIAGRAMS
AND IN THE PARTS LIST ARE CRITICAL
TO SAFE
OPERATION. REPLACE
THESECOMPONENTS
WITH
SONY PARTSWHOSE
PART NUMBERS
APPEAR
AS
SHOWN
IN THISMANUAL OR IN SUPPLEMENTS
PUB-
LISHED
BY SONY.
ATTENTION AU COMPOSANT
AYANT RAPPORT
À le sÉcuntrÉt
LESCOMPOSANTS
IDENTIFIÉS
PAR
UNE
MAROUE
a
SUR LESDIAGRAMMES
SCHÉMATIOUES
ET LA LISTE
ôes prÈces
soNr cRtrtouEs
PouRLAsÉcuRlrÉ
DE FONCTIONNEMENT. NE REMPLACER CES COM'
POSANTS OUE PAR DES PIÈCES SONY DONT LES
NUMÉROS SONT DONNÉS OAruS CE MANUEL OU
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY'
SONY" MoDEL
No.
rA'EroooEsD
--
DTGITAL
PROCESSING
CONTROL.AMPLIFIER
US,Canadian
Model:
AC: 120V60Hz 35W
AEP,
West
Germany
(WG)
Model AC:.
22OY
- 50l60Hz
To Exposed Metal
Parts on Set
0.1
5
pF AC
voltmeter
p.75v)
Fig. A. lJsing an AC voltmeter to check AC leakage'