5.2.2 Reader Setting
Example 2: WG Port does not wire to any WG reader
CH1 CH2 WG
Node ID 1Node ID 9
Node ID 2Node ID 10
Node ID 3Node ID 11
Node ID 4Node ID 12
Node ID 5Node ID 13
Node ID 6
Node ID 7
Node ID 8
Step 2. Door #: enter Door Number
Step 3. Relay Port: Available for WG Port 0*, RS485 CH1 Node ID 3, and RS485 CH2 Node ID 9.
This setting is to enable reader wired under AR-716-E16 to use on-board relay output instead of
the access controller own relay.
K1/K2: the built-in relay of control panel to externally control the electric lock (if this function is
selected, access controller's connection to electronic lock is disabled, and the electric
lock is connected to the K1/K2 contact). It is suitable for public door access such as Gate
& Back Door access to provide safer connection.
For example: Gate installed Node ID 3 use K1 contact and Back Door installed Node ID 9
use K2 contact.
K3 :Public alarm
None: Use the access controller on-board relay to control the electric lock
*WG Port 0 Relay Port option is only for dual door interlocking with CH2 Node ID 9 (Node
ID 9 controller must be activated dual-door interlocking function by inputting command 44*)
Partial AR-716-E16 Parameter Setting is divided into ‘Main’& ‘WG’
‘Main’section is for AR-716-E16 as master controller and WG Port 0 reader
‘WG’section is for WG Port 1 reader
Part Four Operation Manual / Chapter 1 701ServerSQL
5.2 Control Panel AR-716-E16 Parameter Setting