IM-P054-08 CH Issue 5 3
1. Safety information
1.1 Intended use
Referring to the Installation and Maintenance Instructions, name-plate and Technical
Information Sheet, check that the product is suitable for the intended use/application.
The products comply with the requirements of the European Pressure Equipment
Directive 97 /23 /EC and fall within the category 'SEP'. It should be noted that
products within this category are required by the Directive not to carry the mark.
i) The products have been specifically designed for use on compressed air,
which is in Group 2 of the above mentioned Pressure Equipment Directive.
The products’ use on other fluids may be possible but, if this is contemplated,
Spirax Sarco should be contacted to confirm the suitability of the product for
the application being considered.
ii) Check material suitability, pressure and temperature and their maximum and
minimum values. If the maximum operating limits of the product are lower than
those of the system in which it is being fitted, or if malfunction of the product
could result in a dangerous overpressure or overtemperature occurrence, ensure
a safety device is included in the system to prevent such over-limit situations.
iii) Determine the correct installation situation and direction of fluid flow.
iv) Spirax Sarco products are not intended to withstand external stresses that may
be induced by any system to which they are fitted. It is the responsibility of the
installer to consider these stresses and take adequate precautions to minimise
them.
v) Remove protection covers from all connections and protective film from all
name-plates, where appropriate, before installation on steam or other high
temperature applications.
Safe operation of these products can only be guaranteed if they are properly
installed, commissioned, used and maintained by qualified personnel (see Section
1.11) in compliance with the operating instructions. General installation and safety
instructions for pipeline and plant construction, as well as the proper use of tools
and safety equipment must also be complied with.
Directive 94 / 9 / EC (ATEX95) Declaration
The MPC1 is intended for use in potentially explosive environments as defined by
Equipment Group II Category 2.
• We have determined the MPC1 is a 'simple' mechanical product. It is therefore not
covered by the scope of the ATEX directive and consequently does not need to carry
any marking
As part of our conformity assesment, an ignition hazard analysis to EN 13463-1 was
conducted with the following outcome:
• We have determined the MPC1 does not have its own effective sources of ignition - even
in the event of rare failures.
Note: As defined by the European ATEX Standing Committee... "Electrostatic charges
caused by the flow-through of a medium are not considered as "own" ignition source in
the sense of directive 94 / 9 / EC."
The MPC1 may be used in a potentially explosive environment, as defined by Equipment
Group II Category 2, when used in accordance with its Installation and Maintenance
Instructions (IM-P054-08).
The MPC1 compressed air filter / regulator is ATEX compatible -