manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Stateurop
  6. •
  7. Batteries Charger
  8. •
  9. Stateurop Motorline MX14 User manual

Stateurop Motorline MX14 User manual

1 Rev. 1.0 01/04/10
MX14 Charge sensor
Electronic device with 433.92 Mhz transmitter and Current
sensor of the charge applied to the integrated 230Vac socket.
TECHNICAL DATA
- Power supply: 230V~ 50/60Hz 510W max.
- User output: 230V~ 100-500W Max.
- Working temperature: -10 55°C
- Radio transmitter: 433.92MHz
- Transmitter type coding: Rolling Code
- Dimensions: 100 x 55 x 90 mm.
- Container: ABS UL94V-0 (IP40)
DEVICE INSTALLATION
For excellent functioning, it is very important to choose the
place of installation carefully. Capacity is not only conditioned
by the technical features of the device, but also varies depend-
ing on the radio-electric conditions of the site.
The transmitter has an incorporated antenna.
INITIAL FUNCTIONING CONDITION
The device can only work coupled with one or more control
units, upon first ignition the device contains a property code in
the memory that cannot be amended, of Rolling code type.
FUNCTIONING MODE
The device constantly controls the charge applied to the 230V
current socket. According to the variation of the applied load
absorptions, two distinct transmission codes will be sent at
433.92 Mhz (Descent code if the charge is at maximum, As-
cent code if the charge is in Stand-By or disconnected).
The device is ready for functioning with pre-defined charge
settings. In case of anomalous functioning compared to
wanted ones, it will be necessary to program the device.
PROGRAMMING METHOD OF THE DEVICE
The programming of the device current threshold is the Self-
learning type and is performed in the following way: connect
the charge to be checked
and bring it in the condition of maximum current absorption,
press the SEL key, three sounds will be heard confirming pro-
gramming entry. After approx. 3 seconds, the device will emit
a confirmation sound to signal the occurred programming of
the new current threshold, subsequently four confirmation
sounds will be heard to signal the end of the programming
mode.
Whereas if, after having pressed the SEL key the device can-
not memorise any current threshold within 15 seconds the de-
vice will emit four confirmation sounds, signalling the end of
the programming phase.
It is possible to repeat the above described programming op-
eration for the acquisition of new parameters of the applied
charge.
MANUAL TRANSMISSION METHOD OF THE DEVICE
The transmission of the device can be forced, for example, to
facilitate programming on the control unit to be coupled as fol-
lows: connect the device to the electric network keeping the
SEL key constantly pressed for 5 seconds, six sounds will be
heard confirming the sending of only the Descent code of the
device at 433.92 Mhz.
It is possible to repeat the above described transmission op-
eration for a new sending of the transmission code.
SOUND SIGNALS
1 BIP = Memorised current threshold.
3 BIP = Programming phase start
4 BIP = Programming phase end
5 BIP = Deletion of memorised current threshold.
6 BIP = Sending of transmission code
RESET
Should it be necessary to restore the control unit to default
setting (without memorised current threshold), press the SEL
key continuously for 5 seconds, the control unit will emit five
confirmation sounds and the operation will be complete.
GB
2 Rev. 1.0 01/04/10
IMPORTANT FOR THE INSTALLER
- The device must never be used by children or persons with
reduced physical-psychological abilities, unless supervised or
trained on the functioning and the use modalities.
- Do not allow children to play with the device and keep the ra-
dio-controls away from their reach.
- ATTENTION: keep this instruction manual and respect the
important safety prescriptions contained herein. The non com-
pliance with the prescriptions may cause damages and serious
accidents.
- Frequently examine the plant to detect any signs of damag-
ing. Do not use the device if a repair intervention is necessary.
Attention
All operations which require the opening of the casing (cables
connection, programming, etc.) must be carried out by expert
personnel during installation. For any further operation which
requires the casing to be re-opened (re-programming, repair or
installation amendments) contact the after-sales assistance.
STATEUROP declares that the product:
MX14
is in compliance with the specifications of R&TTE Directives
99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC Directives.

Popular Batteries Charger manuals by other brands

EVBox BusinessLine manual

EVBox

EVBox BusinessLine manual

Goobay 71808 user manual

Goobay

Goobay 71808 user manual

Kogan KACRDQIS4XA user manual

Kogan

Kogan KACRDQIS4XA user manual

Sealey WCB3 quick start guide

Sealey

Sealey WCB3 quick start guide

Vanner SP00143/181 owner's manual

Vanner

Vanner SP00143/181 owner's manual

KeyOuest KO037515 quick start guide

KeyOuest

KeyOuest KO037515 quick start guide

Enplus Silk Series user manual

Enplus

Enplus Silk Series user manual

Intermec SF51 user guide

Intermec

Intermec SF51 user guide

Colorovo PowerBox 6800 user guide

Colorovo

Colorovo PowerBox 6800 user guide

Smartech WBC-250 Operator's manual

Smartech

Smartech WBC-250 Operator's manual

PIXO C-USB instruction manual

PIXO

PIXO C-USB instruction manual

Gunson G4104 quick start guide

Gunson

Gunson G4104 quick start guide

Dometic NDS SCE320 Short Operating Manual

Dometic

Dometic NDS SCE320 Short Operating Manual

ABB HT572708 Operation manual

ABB

ABB HT572708 Operation manual

EVOline Square80 manual

EVOline

EVOline Square80 manual

Redarc SBC24025 Operating instructions and owner's manual

Redarc

Redarc SBC24025 Operating instructions and owner's manual

Absaar HV04 manual

Absaar

Absaar HV04 manual

DazeTechnology Cover Dazebox Home installation manual

DazeTechnology

DazeTechnology Cover Dazebox Home installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.