Introduction
TheCMCP420VT/ExSeriesSensorsareATEX/IECExapproved4‐20mAoutputsensors
designedtomonitormachineryhealthandprovidereliablereal‐timedatatoimprove
machinereliability.Theseriesisavailableintwoprimarytype,eitherVibrationonlyor
VibrationandTemperature.Bothsensorsprovidea4‐20mAoutputforeachparameter
thoughtheVibrationonlymodelalsoincludesabuffered100mV/gdynamicsignaloutput
ontheterminalblock.TheCMCP420VTSeriesaretypicallyinstalledonabearinghousing,
ormachineframe,andconnectbacktotheuser’sPLC,DCS,SCADAorothercontrol
systemwherethe4‐20mAsignalscanberecorded,trendedordisplayed.Each
CMCP420VT/Exsensorisprovidedwithanapprovedflameproofhousing.
ItemsIncluded
CertificateDetails
IECExBAS20.0003X
Baseefa20ATEX0011X
II2G
ExdbIICT6(‐20°C≤Ta≤+79°C)
SpecificConditionsofUse:
1. Thetemperatureattheflameproofenclosureshallnotexceed85°C.
TypicalInstallation(StudMount)
1. Preparemountingsurfaceusingaspotfacingkit,suchastheCMCP270L,to
createa1.0”(25.4mm)flatsurface.
2. Drillandtapthecenterholeforthecorrectmountingthread.Thesensoris
suppliedwithboth¼‐28andM8x1.25threadadapters.Mountingpadsmaybe
usedwithanextendedlengthmountingscrewormountingpadscanbeglued
tothemountingsurfaceusingasuitableadhesive.
3. Cleansurfacewithadegreasingagent.
4. Applyathinfilmofsiliconedialecticgreasetoachieveahigherdegreeof
surfacecontactbetweenthesensorandmountingsurface(ifnecessary).
5. Screwthesensorontothemountingstudandtorqueto9Nm.
6. Attachtheflameproofhousingtothesensor.
7. Torquethehousingto30Nm.
8. InstallconduitorflameproofcableglandperIEC/EN60079‐1.
9. Usingtwisted/shieldedcable,connectthesensortothecontrolsystemperthe
diagramshowninthewiringdetailsbelow.Allconnectionsaretobemade
insidethehousingandmustusecableratedforaminimumof85°C.
10. RefertoCMCP420VT/Exinstallationdrawingsformoredetail.
InstallationNote:
Variousmountingadapters,padsandadhesivesareavailableforalternatemounting
techniques.ContactSTIformoreinformation.
WiringDetails
4‐20mAScaling
VibrationOutputTemperatureOutput
ModelImperialMetricImperialMetric
CMCP420VT‐010to1.00in/s0to25.4mm/sN/AN/A
CMCP420VT‐020to2.00in/s0to50.8mm/sN/AN/A
CMCP420VT‐T10to1.00in/s0to25.4mm/s‐32to212°F0‐100°C
CMCP420VT‐T20to2.00in/s0to50.8mm/s‐32to212°F0‐100°C