– 4 –
THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE Mini™ WATER
HEATER. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS
MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SE-
RIOUS BODILY INJURY AND/OR DEATH. ALL INSTALLATIONS MUST BE CARRIED OUT BY A LICENSED
ELECTRICIAN AND LICENSED PLUMBER.
– Special uses in photo developing shops,
laboratories etc.
The Mini™ can also be used for whole apart-
ments and homes in warm climate zones
such as the Caribbean region, Central Amer-
ica and Mexico due to the higher ambient
water temperatures.
Mounting the unit
UNIT MUST BE INSTALLED WITH THE
PLUMBING CONNECTIONS POINTING
DOWNWARD OR UPWARD. DO NOT IN-
STALL UNIT WHERE IT WOULD ROUTINELY
BE SPLASHED WITH WATER. ELECTRIC
SHOCK MAY RESULT.
1. Install Mini™ as close as possible to the
hot water draw-off point, for example,
directly underneath the sink or next to
the shower stall.
2. Install Mini™ in a frost free area. If frost
may occur, remove unit before freezing
temperatures set in.
3. Leave a minimum of 5" of clearance on
all sides for servicing.
4. Remove screws left and right and remove
plastic backplate by pulling on the tab
with a screwdriver B.
5. Mount backplate securely to wall by put-
ting two screws through mounting holes
A B.
6. Snap unit back into the backplate and
reinstall the two screws.
Water connections
IF SOLDERING NEAR THE UNIT IS
NECESSARY, PLEASE DIRECT THE
FLAME AWAY FROM THE HOUSING OF THE
UNIT IN ORDER TO AVOID DAMAGE. ALL
PLUMBING WORK MUST COMPLY WITH
NATIONAL AND APPLICABLE STATE AND
LOCAL PLUMBING CODES. NOTE: EXCES
SIVE HEAT FROM SOLDERING ON COP
PER PIPES NEAR THE Mini™ MAY CAUSE
DAMAGE.
1. A pressure reducing valve must be in-
stalled if the cold water supply pressure
exceeds 150 PSI (10 bar).
2. Make certain that the cold water supply
line has been flushed to remove any scale
and dirt.
3. Install an isolating valve in cold water line
as shown in illustration C. This allows the
unit to be isolated for maintenance pur-
poses.
4. When the plumbing connections are fac-
ing downward the cold water connection
(inlet) is on the right side of the unit, hot
water connection (outlet) is on the left
side of unit.
5. Tankless water heaters such as the Mini™
are not required to be equipped with a
Pressure and Temperature Relief Valve. If
the
local inspector will not pass the instal-
lation
without a relief valve, it should be
installed on the hot water outlet side of
the unit.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION
OF THIS WATER HEATER, OR IF YOU NEED AN ADDITIONAL INSTALLATION MANUALS,
PLEASE CALL OUR TECHNICAL SERVICE LINE AT 800-582-8423 (USA AND CANADA ONLY).
IF YOU ARE CALLING FROM OUTSIDE THE U.S. AND CANADA, PLEASE CALL USA 413-247-3380 AND WE
WILL REFER YOU TO A QUALIFIED STIEBEL ELTRON SERVICE REPRESENTATIVE IN YOUR AREA.
STIEBEL ELTRON, INC. WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO
COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS
MANUAL OR BECAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE OF THIS
APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER. FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS WARRANTY.
NEVER REMOVE THE UNIT’S PLASTIC COVER UNLESS THE ELECTRICITY IS TURNED OFF.
General
The Mini™ tankless water heater differs from
conventional storage type water heaters. It
does not store hot water. Instead, water is
heated instantaneously as it flows through
the unit. The powerful heating elements
are activated by a flow switch as water is
drawn from a hot water faucet connected
to the Mini™. Due to the absence of stand-
by losses, the Mini™ has greater energy
efficiency than storage type water heaters.
Also, the unit will continuously supply hot
water as long as the faucet is open.
The temperature of the hot water delivered
by the Mini™ depends on the wattage of
the heating element, the temperature of
the incoming cold water, and the water
flow rate through the unit. In order for
the Mini™ to operate properly, it must be
carefully matched to the application. In
case you have questions regarding the
way you plan to use the Mini™, please call
our technical service line at 800-582-8423
(USA and Canada). For service outside
the U.S. and Canada, please call us at USA
413-247-3380. You can also e-mail us at
413-247-3369.
The Mini™ can be used for hand washing
type applications in the U.S. and Canada:
– Restroom sinks in commercial/industrial
facilities and homes
– Kitchen areas in commercial /industrial
facilities and homes
- 4 -