UREA/DEF AC TRANSFER PUMP
USER’S MANUAL
E. INSTALLATION
MODEL NUMBER
17350250 & 17350251
E3. CONNECTING THE TUBING
• Before connection, make sure that the tubing and the suction tank are free of dirt and thread residue that could damage the pump and
its accessories.
• Before connecting the delivery tube, partially fill the pump body with fluid to facilitate priming.
• Do not use conical threaded joints that could damage the threaded pump openings if excessively tightened.
SUCTION TUBING:
- Minimum recommended nominal diameter: 3/4”
- Nominal recommended pressure: 10bar / 145psi
- Use tubing suitable for functioning under suction pressure
DELIVERY TUBING:
- Minimum recommended nominal diameter: 3/4”
- Nominal recommended pressure: 10bar/145psi
ATTENTION!
It is the installer’s responsibility to use tubing with adequate characteristics.
Loosening of the connections (threaded connections, flanging,gasket seals) can cause serious ecological and safety problem.
Check all the connections after the initial installation and on a daily basis after that.
Tighten the connections,if necessary.
F. DAILY USE
G. MAINTENANCE
a. If using flexible tubing, attach the ends of the tubing to the tanks. In the absence of an appropriate slot, solidly grasp the delivery tube
before beginning dispensing.
b.Before starting the pump,make sure that the delivery valve is closed (dispensing nozzle or line valve).
c.Turn the ON/OFF switch to ON.The by-pass valve allows functioning with the delivery closed only for brief periods.
d. Open the delivery valve,solidly grasping the end of the tubing.
e. Close the delivery valve to stop dispensing.
f. When dispensing is finished, turn off the pump.
ATTENTION!
Function with the delivery closed is only allowed for brief periods (2-3 minutes maximum).
After using,make sure the pump is turned off.
All models are designed and constructed to require a minimum of maintenance.
In any case always bear in mind the following basic recommendations for a good functioning of the pump:
- On a weekly basis, check that the tubing joints have not loosened,to avoid any leakage.
- On a monthly basis, check the pump body and keep it clean of any impurities.
- On a weekly basis, check and keep clean the line suction filter.
- On a monthly basis, check that the electric power supply cables are in good condition.
H. NOISE LEVEL
Under normal working conditions the noise emission from all models does not exceed the valve of 75 db at a distance of 1 meter from
the electric pump.
I. DISPOSING OF CONTAMINATED MATERIALS
In the event of maintenance or demolition of the machine, do not disperse contaminated parts into the environment.
Refer to local regulations for their proper disposal.