2. Performance check, minimum flow
2019-10-30
OI06H-5418 SR 601 SR 602 6
2.1 Connect the hose to the
fan unit and turn it clockwise
about 1/8 of a turn.
2.2 Place the head top in the
flow meter and start the fan
unit.
Tip! When the bag is turned
with the measuring tube
inwards it can be used as a
storage bag
2.3 Place the head top in the
flow meter bag and start the
fan unit.
Grip the lower part of the bag
in order to seal around the
hose.
Grip around the measuring
tube and hold the tube
vertical.
The ball should now float
level with or just over the
175 l/min marking.
If the minimum flow is not
achieved, check that:
-The flow meter is vertical
-The ball moves freely
-The bag seals well around
the hose.