Suuwer SUW015 User manual

SUW015
8V/12V 1.5A DC
Suitable for 8V/12V Normal Lead Acid, Sealed, Leisure, A M or el-
Batteries between 5-75Ah
2
INTRODUCTION
The SUUWER SUW015 is a member of the family of advanced battery chargers
manufactured by SUUWER International Ltd. SUUWER chargers ill increase your
battery’s performance and prolong its life.
We have taken numerous measures in quality control to ensure that your product
arrives in top condition and ill perform to your satisfaction.
Please carefully read and follow the safety and operating instructions. Not
following these instructions may result in a serious accident, including
damaged property or serious injuries.
IMPORTANT SAFETY INSTRUCTIONS
If you are not confident orking ith 8V/12V DC voltage or are unsure of hat you are
doing, consider to seek for professional help e.g. a car garage or your vehicle´s
manufacturer.
Read your vehicle's owner's manual!
Some vehicle manufacturers may have special requirements before charging the
vehicle´s battery. (e.g. fuses that have to be removed or certain security demands).
You MUST NOT connect to 6V & 24V or other unsuitable batteries
(e.g. NiCd-batteries). The battery charger is not designed as a
power supply. Not following these instructions could cause serious
personal injury or material damage.
This unit has safeguards against reverse-polarity and short-circuit.
Although it is highly recommended not to touch or connect the red
to the black clamps or to connect the leads in reverse polarity. This
could cause dangerous sparks and electric arcing. Only connect
and disconnect the battery leads when the mains supply is
disconnected.
Use the charger in dry environment only. Do not use the unit close to open fire.
Do not operate the unit in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Please stop using the device, if the unit is
getting very hot, is smoking or is showing any abnormal behaviour. SUUWER is
not liable for any direct or indirect damages or injuries caused by the use of
the device, especially caused by failure to follow these instructions.
TYPE OF BATTERIES
This charger is intended to be used 8V/12V Normal Lead Acid, VRLA, Sealed (MF
Maintenance-Free), Leisure, AGM or Gel-Batteries bet een 5-75Ah. Do not try to
charge unsupported types of batteries like NiCd.
ASES
When the battery is being charged, you may notice bubbling in the fluid caused by the
release of gas. As the gas is flammable, avoid naked flames, glo ing or electrostatically
charged material and sparks in the vincity of the battery. Provide adequate ventilation.
Because of this risk of explosive gas, only connect and disconnect the battery leads
hen the mains supply is disconnected.
3
STORA E
When not in use, store the battery charger in a dry environment.
MAINTENANCE
Don’t try to open the body casing. There are no user-serviceable parts inside. Damage
due to improper use, modifications or attempted repairs lead to the exclusion of liability
and the loss of arranty. The mains supply cord of this device cannot be replaced; if
the cord is damaged, the appliance should be discarded.
PRECAUTIONS WHEN WORKIN WITH BATTERIES
Avoid getting electrolyte on your skin or clothes. It is acidic and can cause burns.
If battery acid contacts skin or clothing, ash immediately ith soap and ater.
Baking soda neutralizes lead acid battery electrolyte. If electrolyte gets into your
eyes, immediately flood your eyes ith running cold ater for at least 20 minutes
and get medical attention immediately. Eye protection is therefore recommended.
Never charge a frozen battery. If battery fluid (electrolyte) becomes frozen, bring the
battery to a arm area to allo the battery to tha before you begin charging.
Do not touch the battery clamps together hen the charger is on.
Never use the charger hen it has received a hard blo , been dropped, or other ise
been damaged. Take it to a qualified professional for inspection and repair.
Prevent the po er cord from being stepped on, tripped over, or being damaged.
Never pull out the plug by the cord hen unplugging the charger. Pulling on the cord
may cause damage to the cord or the plug.
Although it is usually possible ithout causing problems to charge the battery hen
installed, e recommend to remove the battery from the car before charging. When
charging the battery hile installed in the car, SUUWER cannot take any
responsibility for harm to your car electronic or the car itself.
Never smoke or allo a spark or flame in vicinity of battery or engine.
Al ays keep metal objects or other materials that can short circuit battery terminals
securely a ay from the batteries. The resulting spark or short-circuit may cause an
explosion and can produce a current high enough to eld a ring or the like to metal.
Remove personal metal items such as rings, bracelets, necklaces, and atches hen
orking ith starter batteries.
PARTS
SUW015 main unit
1 set of crocodile clamps
1 set of ring terminals (for a permanent installation)
4
FEATURES
INTELLI ENT CHAR IN
The SUW015 has a built in microprocessor using high frequency technology, that
digitally controls the 3 stages of battery charging: constant current, constant voltage
and floating charge. The charger automatically checks the status of the connected
battery and adjusts the charging current. When the battery is fully charged the charger
s itches automatically to float charge: the charger can stay connected to the battery
permanently (ideal for seasonally used vehicles).
Charging characteristic:
1. Initialization: Initialize diagnostic battery performance and desulfating the battery
through 17V pulse.
2. Bulk: Major charging stage here the battery receives the majority of its charge.
During this stage the battery brought to 75 - 80% of its charger. The SUW015
charger delivers maximum current until the terminal voltage has risen to the full
charge level for Normal battery.
3. Absorption: Completes the charge up to virtually 100% at a constant voltage. The
current tapers off after the current reached the minimum level.
4. Float: Maintenance charging at constant voltage, keeping the batteries at 100%
charge. Float mode chargers indefinitely ithout damaging the battery.
Operating characteristics :
Modes 8V Battery 12V Battery Temperature
Automatic
Detection
hether voltage exceeds
charging voltage (3.5V)
hether voltage exceeds
charging voltage (3.5V) 0~40℃
Constant
Current
1.5A, until the voltage
reaches 9.5V
1.5A, until the voltage
reaches 14.1V 0~40℃
Constant
Voltage
Current reduces until
voltage reaches 9.6V
Current reduces until
voltage reaches 14.2V 0~40℃
Floating
Charge
8.8V, output current
avoids battery voltage
dropping
13.2V, output current
avoids battery voltage
dropping 0~40℃
5
CABLE CONNECTOR
The SUW015 offers t o options for connecting the battery. Via the cable connector you
can select hich connection you ant to use:
Crocodile clamps for easy and flexible use.
Ring Terminals for permanent installation on your battery.
LED INDICATOR LAMP
The built-in double color LED lamps indicate the status of the charger:
RED LED
oFLASHING RED: not charging battery,Reverse battery, Mode selection error.
oSOLID RED: battery charging.
REEN LED
oFLASHING GREEN: battery greater than 80% charged.
oSOLID GREEN: full charged.
CHAR IN MODE
The unit has 2 kinds of battery mode: 8V and 12V Lead-Acid .
IMPORTANT: When you choose battery mode, you must first disconnect the battery.
REVERSE-POLARITY PROTECTION
This unit offers reverse-polarity protection: the LED WILL FLASH RED ONCE after
connecting the unit to the battery. The charging process ill not start. When verify if all
cables are correctly connected. Connect the red crocodile clip to positive (+) battery
post, and black crocodile clip to negative (-) post, then the charging process ill restart.
SHORT-CIRCUIT PROTECTION
If the crocodile clamps accidentally touch together hilst the mains po er is connected,
the unit ill stop charging. When verify if all cables are correctly connected. being
careful not to touch the clips together. Connect the red crocodile clip to positive (+)
battery post, and black crocodile clip to negative (-) post, then the charging process ill
restart.
6
OPERATION
PLEASE READ CAREFULLY BEFORE USIN THE DEVICE
This system is intended to be used 8V/12V Normal Lead Acid, VRLA, Sealed
(MF), Leisure, A M or el Batteries between 5-75Ah.
1. PREPARIN THE BATTERY
It is recommended to disconnect the battery from the car if possible. This ill avoid
possible damage to the alternator and your car´s electronic system. To avoid damage
to the body ork from possible spillage, it is also recommended to remove the battery
completely from the vehicle. It is advisable to use personal protective clothing (safety
goggles and gloves are highly recommended) hen handling the battery, as there is a
high possibility of corrosive acid being on the outside of the battery.
For permanently sealed battery, it is not necessary to carry out the following
checks. Don´t try to open a sealed or maintenance-free battery.
Firstly remove the caps from each cell and check that the level of the liquid is sufficient
in each cell. If it is belo the recommended level, top up ith de-ionized or distilled
ater.
ATTENTION: Under no circumstances should tap ater be used. The cell
caps should not be replaced until charging is complete. This allo s any
gases formed during charging to escape. It is inevitable that some minor
escape of acid ill occur during charging.
2. CONNECTIN THE CHAR IN CABLES
Connect the clamps or ring terminals to the battery in the follo ing order:
Connect the positive charging lead (RED) to the positive terminal post of the battery
(marked +).
Connect the negative charging lead (BLACK) to the negative post of the battery
(marked -).
It is important to ensure that all connections are making good contact ith their
respective terminal posts. No you can connect the charger to the mains supply to start
charging.
3. CHAR IN
During the charging process, consider the LED indicator lamps on the main unit.
4. AFTER CHAR IN
Please note: For reasons of safety, al ays connect and disconnect crocodile clamps
from the battery ith the mains plug disconnected.
Unplug charger from the mains supply and disconnect the clamps from the battery
posts. If the charged battery is maintainable, inspect the liquid in each cell again and
top up carefully if necessary. No replace the caps. Any surplus fluid around the cell
tops should be iped off ith extreme care as it may be acidic.
7
BATTERY MAINTENANCE AND CARE
It is essential to keep your battery regularly charged throughout the year, especially
during the inter months. Lo temperature reduces the effectiveness of your car
battery and your motor oil is thicker. Engines are more difficult to start and the heater,
indscreen ipers and lights are all draining po er. It is at this time that batteries have
to be at peak po er. If your battery is not regularly maintained and kept fully charged,
it can cause problems and a possible breakdo n.
Listed are some helpful hints on ho to keep your battery healthy in conjunction ith
your SUUWER battery charger:
Detecting faulty Cells with a hygrometer
(not possible with sealed or maintenance-free batteries)
Starter-Batteries are usually made of several cells, ith a nominal voltage of 2V per cell.
If one of the cells is defective, the hole battery deteriorates. If, after several hours of
charging, your battery is still flat, you should test the battery cells.
Using a hydrometer, hich can be purchased from most motor accessory stores, you
can check the specific gravity of the electrolyte in each cell. Take hydrometer readings
from each cell in the battery. Put the fluid back into the cell after testing, taking care
not to spill the fluid. If one reading is lo er than the others, this could indicate a faulty
cell. If necessary, get an auto-electrician to check your battery. In some cases a battery
can be revived, but one faulty cell is enough to ruin your battery.
Care
Sometimes the battery may appear flat, but the reason could simply be dirty or loose
connections on your battery terminals. It is important to maintain the leads on a regular
basis. Clean all contacts and grease them using terminal grease. Make sure that all
connections are tight.
It is essential to keep the electrolyte level above the plates, note that you should not
overfill it, as the electrolyte is strongly acidic. When topping up, do not use tap ater.
Al ays use distilled or de-ionized ater. It is important to keep the acid level up. If
necessary have it checked by your garage.
8
TECHNICAL SPECIFICATIONS
SUW015 main unit
Suitable Batteries
Normal Lead Acid, VRLA, Sealed (MF),
Leisure, AGM or Gel Batteries bet een 5-
75Ah capacity
Suitable Battery Voltages 8V, 12V
Charging Current 1.5A DC
Electrical Safeguards Protection against: overheat, short-circuit,
reverse polarity, sparks
Maximum conversion efficiency ≥80%
AC Input AC 100V – 120V ~ 50/60Hz; Max. 26W
DC Output 12V Battery: Max. 14.2V, 1.5A DC
8V Battery: Max. 9.6V, 1.5A DC
This model may be operated in USA countries.
ENVIRONMENTAL PROTECTION
The product is classed as Electrical or Electronic Equipment and should
not be disposed of ith other household or commercial aste at the end
of its orking life. Please recycle here facilities exist. Ask your local
authority or retailer for recycling advice.
WARRANTY
SUUWER arrants this product for a period of 2 years from the date of purchase to the
original purchaser. Warranty is not transferable. Warranty covers defect against
orkmanship and materials only. To obtain arranty service, please return the unit to
the place of purchase or your authorized SUUWER dealer together ith your proof of
purchase. The arranty is void, if the product has been damaged or not used as
described in this manual. Warranty is void, if a non-authorized repair has been
performed. SUUWER makes no other arranty expressed or implied. SUUWER is only
responsible for repair or replacement (at Pro-Users’ Discretion) of the defective product
and is not responsible for any consequential damage or inconvenience caused by the
defect.

Popular Batteries Charger manuals by other brands

AEG BL18DP-LE Original instructions

AEG

AEG BL18DP-LE Original instructions

Leviton Evr-Green DC Operation and maintenance guide

Leviton

Leviton Evr-Green DC Operation and maintenance guide

Kompernass TRONIC TLG 1750 B3 operating instructions

Kompernass

Kompernass TRONIC TLG 1750 B3 operating instructions

Eaton Green Motion DC 22 installation manual

Eaton

Eaton Green Motion DC 22 installation manual

CHARGESPOT E15 product manual

CHARGESPOT

CHARGESPOT E15 product manual

ANSMANN ENERGY 8 PLUS operating instructions

ANSMANN

ANSMANN ENERGY 8 PLUS operating instructions

Chicago Pneumatic CP12CHK Operator's manual

Chicago Pneumatic

Chicago Pneumatic CP12CHK Operator's manual

DIC 711 Mounting and operating instructions

DIC

DIC 711 Mounting and operating instructions

Trust 220BS quick start guide

Trust

Trust 220BS quick start guide

Vantage Hearth VAN-W4F-5W2/LI manual

Vantage Hearth

Vantage Hearth VAN-W4F-5W2/LI manual

Bosch PLN-24CH10 Installation and user instructions

Bosch

Bosch PLN-24CH10 Installation and user instructions

Renesas ISL9241 Application note

Renesas

Renesas ISL9241 Application note

Harbor Freight Tools 65063 Set up and operating instructions

Harbor Freight Tools

Harbor Freight Tools 65063 Set up and operating instructions

Goobay 52955 manual

Goobay

Goobay 52955 manual

SPE CBHF2 NA operating manual

SPE

SPE CBHF2 NA operating manual

Associated 6010A Operator's manual

Associated

Associated 6010A Operator's manual

Techly I-CABINET-80DUTY user manual

Techly

Techly I-CABINET-80DUTY user manual

ABB HT606275 Operation manual

ABB

ABB HT606275 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.