SYStronics STH-PR5N-F User manual

Other SYStronics Temperature Controllers manuals

SYStronics STH-PD5N F User manual

SYStronics

SYStronics STH-PD5N F User manual

SYStronics TIC-4M User manual

SYStronics

SYStronics TIC-4M User manual

SYStronics TIC-2M User manual

SYStronics

SYStronics TIC-2M User manual

Popular Temperature Controllers manuals by other brands

Brookfield TC Series Operator's manual

Brookfield

Brookfield TC Series Operator's manual

Nibe HPAC 45 Installer manual

Nibe

Nibe HPAC 45 Installer manual

Auber TD100 instruction manual

Auber

Auber TD100 instruction manual

IntelliSense INTELLITEMP T-1000 installation instructions

IntelliSense

IntelliSense INTELLITEMP T-1000 installation instructions

Swegon LUNAd MB Instructions for use

Swegon

Swegon LUNAd MB Instructions for use

Lucky Reptile Thermo Control II Operation instructions

Lucky Reptile

Lucky Reptile Thermo Control II Operation instructions

SMC Networks Thermo-con INR-244-639 Operation manual

SMC Networks

SMC Networks Thermo-con INR-244-639 Operation manual

SENSORMETRIX Argon 100 manual

SENSORMETRIX

SENSORMETRIX Argon 100 manual

Fuji Electric PXE4 instruction manual

Fuji Electric

Fuji Electric PXE4 instruction manual

Yuyao gongyi XMT-808 series Operation manual

Yuyao gongyi

Yuyao gongyi XMT-808 series Operation manual

eltherm Ex-TC It Series operating instructions

eltherm

eltherm Ex-TC It Series operating instructions

Selec TC544C user guide

Selec

Selec TC544C user guide

P.W. KEY rt-208gt operating manual

P.W. KEY

P.W. KEY rt-208gt operating manual

Omron C200H-TV Series Operation manual

Omron

Omron C200H-TV Series Operation manual

BH Thermal BriskONE owner's manual

BH Thermal

BH Thermal BriskONE owner's manual

West Control Solutions KS 45 Operation Notes

West Control Solutions

West Control Solutions KS 45 Operation Notes

Opt Lasers TEC-8A-24V-PID-HC operating manual

Opt Lasers

Opt Lasers TEC-8A-24V-PID-HC operating manual

Vaillant VR 92/3 Operating and installation instructions

Vaillant

Vaillant VR 92/3 Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

STH-PR5N_F MANUAL
1
USER MANUAL
Temperature·Humidity Sensor for Record Output
VER:201805-1.0
STH-PR5N F
-
SYStronics. Co. ltd.,
1404, 301, Bucheon Techno park, 345, Seokcheon-ro, Bucheon-si, Gyeonggi-do, Republic of Korea
Phone : +10-32-324-2777 Fax : +10-32-324-2717 Homepage : www.ss22.com
STH-PR5N_F MANUAL
2
Be sure to read and ensure that your safety precautions are used to protect your safety and prevent property
damage. We shall not accept any liability for any loss caused by the use or carelessness caused by the use
or handling of this manual.
Warning
If this product is not intended as a safety device, use a double safety device for fear of accidents, damage of
critical peripheral equipment, and equipment that is feared to cause extensive property damage.
Safety instructions
1. Be sure to check the equipment after disconnecting mains.
2. Do not disassemble and repair this product ; it is not possible to manufacture any product.
3. Do not spray water directly or clean it with benzene, jazzy, or alcohol.
Notes on the environment
Do not install this product in the following locations and environments :
1. Places directly exposed to mechanical vibration or shock
2. Places exposed to corrosive gases or combustible gases
3. Position directly exposed directly to direct sunlight
4. Places affected by electromagnetic waves
5. Places where high temperature or humidity is high (sites with over 85 % of ambient humidity)
6. Places where dust and salt are plentiful
Precautions on installation
1. Make sure that the installation work is related to the installation or qualified personnel only.
2. Do not place any device or wiring that caused noise (NOISE) near the product.
3. Avoid near heating apparatus.
4. Disconnect all appliances (OFF) after disconnecting them from the wiring.
5. Do not work with wet hands. Risk of electric shock.
6. Install and use the method described in the User Manual as instructed in the Instructions for Use.
7. Do not turn on (power on) prior to the connection between the unit of manufacture of this unit.
8. Do not use any load exceeding the opening and closing capacity of the output contacts.
Immunity condition
1. In addition to the contents set forth herein, no warranties and responsibilities shall be made regarding this
product.
2. Whether or not this product is likely to be unforeseen defects and natural disasters due to the use of this
product, the user or the third person We shall not be held liable for any indirect damage.
Precautions
STH-PR5N_F MANUAL
3
Product Overview
It is a room type sensor that can incorporate a digital temperature·humidity sensor element and
install it in equipment and favorite place. And It is easy to use in the field where the temperature and
humidity need to be precisely monitored such as the thermo-hygrostat, low-temperature warehouse. And It is
a product that can output temperature and humidity data as analog signals. In addition, it is easy
to monitor and set by placing FND and buttons on the front.
·Digital temperature·humidity sensor
·Monitoring with front panel FND
·Temperature·humidity data analog signal output
STH-PR5N_F MANUAL
4
Detailed Structure of Product
Product Component
Sensor probe
ABS
Body fastening screw 4EA
More than M3 ×8
FND Display
4 Digit FND x 2EA
Control unit
Button Key
Sensor body
ABS
Cable gland
PG9
STH-PR5N_F MANUAL
5
Temperature Sensor Specifications
Measuring Range -20.0 ~ 80.0℃
Accuracy ±0.3℃ (Max ±0.4℃)
Resolution 0.015℃
Reaction Time 2.0 sec
Humidity Sensor Specifications
Measuring Range 0 ~ 100% RH
Accuracy ±3% RH (Max ±4.5% RH)
Resolution 0.01% RH
Reaction Time 8.0 sec
Product Specifications
Controller Specifications
Input Power DC 24Vdc
Power Consumption 75mA / 1.8W (at 24Vdc)
Output Spec. DC 1~5V / 4~20mA
Operating Temp. -20 ~ 80℃ (Non condensing)
Operating Humi. 5 ~ 95% (Non condensing)
Storage Temp. 0 ~ 60℃ (Non condensing)
Body Weight 268.0g (Cable basic 3M)
Cable Weight 94.0g
Cable Length Basic 3M (Can be changeable / AWG standard : More than 20)
Temperature Accuracy Graph
0.0
0.5
1.0
1.5
-40 -20 020 40 60 80 100 120
Temperature (℃)
±
±
±
±
T (℃)
0
1
2
3
4
5
6
7
8
010 20 30 40 50 60 70 80 90 100
Relative Humidity (%RH)
±
±
±
±
±
±
±
±
±
RH (%RH)
Humidity Accuracy Graph
Maximal Tolerance
Typical Tolerance
Maximal Tolerance
Typical Tolerance
STH-PR5N_F MANUAL
6
Product Dimension (Unit : mm)
Top view
Front view Side view
STH-PR5N_F MANUAL
7
Installation Method
Securely fix the sensor to the equipment to be installed or the wall with four screws(M3) for body fastening.
Product Installation Method
Mounting dimensions
Please refer to the installation drawing at the bottom for correct operation.
STH-PR5N_F MANUAL
8
Product Wiring Method
Wiring Precautions
1. When wiring, check the polarity and connect the wiring correctly.
2. To avoid malfunction, avoid the use of the same conduit or the same duct for the wiring of high-voltage
lines and power lines and sensors.
3. When changing the supplied cable, connect the communication shield cable of AWG20 or higher standard.
Wiring Diagram
Color Contents Function
RED Sensor power supply (DC 24V / + ) Power supply terminal
GREEN Sensor power supply (DC 24V / - )
WHITE Temperature / humidity record output common terminal (- Terminal)
Record output terminalBLUE Temperature record output terminal (+ Terminal)
BLACK Humidity record output terminal (+ Terminal)
HUMI (+)
TEMP (+)
GND (-)
PWR (-)
PWR (+)
PWR (+)
PWR (-)
GND (-)
TEMP (+)
HUMI (+)
STH-PR5N_F MANUAL
9
Product Wiring Method
Wiring Precautions
1. When wiring, check the polarity and connect the wiring correctly.
2. To avoid malfunction, avoid the use of the same conduit or the same duct for the wiring of high-voltage
lines and power lines and sensors.
Wiring Diagram
HUMI (+)
TEMP (+)
GND (-)
PWR (-)
PWR (+)
PWR (+)
PWR (-)
GND (-)
TEMP (+)
HUMI (+)
Color Contents Function
RED Sensor power supply (DC 24V / + ) Power supply terminal
GREEN Sensor power supply (DC 24V / - )
WHITE Temperature / humidity record output common terminal (- Terminal)
Record output terminalBLUE Temperature record output terminal (+ Terminal)
BLACK Humidity record output terminal (+ Terminal)
STH-PR5N_F MANUAL
10
How to set up the product
Notes on Setting
1. Since it is set as follows inside the sensor when opening the front cover, refer to it when connecting.
2. When shipped from the factory, it will be shipped with the specifications requested in advance. Please
refer to the following documents when changing the analog output specifications.
Image
Item TEMP: 4~20mA
HUME : 4~20mA
TEMP : 4~20mA
HUMI : 1~5V
TEMP : 1~5V
HUMI : 4~20mA
TEMP : 1~5V
HUMI : 1~5V
How to Set the Output
TEMP HUMI TEMP HUMI TEMP HUMI TEMP HUMI