manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TA
  6. •
  7. Control Unit
  8. •
  9. TA TBV User manual

TA TBV User manual

Other TA Control Unit manuals

TA UDV User manual

TA

TA UDV User manual

TA STA User manual

TA

TA STA User manual

TA STAD Series User manual

TA

TA STAD Series User manual

TA STAF Series User manual

TA

TA STAF Series User manual

TA T011S User manual

TA

TA T011S User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

we knowhow
TBV 5-5-20
Terminal valves 2007.01
Application:
Heating and cooling systems.
Functions:
Balancing
Pre-setting
Measuring
Shut-off
Pressure class:
PN 16
Temperature:
Max. working temperature: 120°C
Min. working temperature: -20°C
Material:
Valve body: AMETAL®
Bonnet: AMETAL®
Spindle seal: EPDM O-ring
Seat seal: Metal seated
Handwheel: Polyamide
Smooth ends:
Nipple: AMETAL®
Sealing (DN 25-50): EPDM O-ring
AMETAL® is the dezincification resistant alloy of TA.
Marking:
Body: TA, PN 16/150, DN, inch size and flow direction arrow.
Handwheel: Valve type and DN.
Technical description
5-5-20 - 2
Smooth ends
*) Can be connected to smooth pipes with KOMBI compression coupling. See catalogue
leaflet KOMBI.
Kvs = m3/h at a pressure drop of 1 bar and fully open valve.
Handwheel TBV, complete
Setting of a valve for a given pressure drop, eg corresponding to position 5 is done as follows:
1. Check that the scale is in upper position towards the handwheel before setting (fig 1).
2. Turn the handwheel so that position 5 is pointing at the index* of the valve body (fig 2).
3. Push the scale downwards over the bonnet (fig 3). The valve is now set.
There is a diagram for every valve size that shows the flow for different pressure drops and settings.
TBV
TA N o DN DL HKvs Kg
52 130-015* 15 G1/2 78 72 1.8 0,38
52 130-020* 20 G3/4 91 78 3.6 0,53
TA N o DN DL HKvs Kg
52 430-015 15 15 142 72 1.8 0,48
52 430-020 20 22 173 78 3.6 0,69
Accessories
TA N o
52 130-100
Setting TBV
L
D
H
L
ØD
H
*)
2
13
5-5-20 - 3
Flow deviation at different settings
*) Position
Try to avoid mounting taps and pumps, immediately before the valve.
When ∆p and the design flow are known, use the formula to calculate the Kv-value.
Software
TA Select: Makes it easy to choose the right balancing valves by taking into account the desired flow and pressure drop.
Measuring instruments
Use the balancing instrument TA-CBI or measuring instrument TA-CMI. They are programmed with valve characteristics for TA
valves, enabling measured differential pressure to be read off directly as a flow rate.
For further information on TA-CBI and TA-CMI, see each catalogue leaflet.
Conversion disc
By using the conversion disc it is easy to calculate the relationship between flow, pressure and setting values for all valve sizes.
Manuals
See the following manuals for descriptions of various balancing methods:
Total hydronic balancing
Manual no. 1: Balancing control circuits
Manual no. 2: Balancing distribution systems
Manual no. 3: Balancing of radiator systems
Manual no. 4: Hydronic balancing with differential pressure controllers
Measuring accuracy
Sizing
Support material
Installation
012345678 *)
2
4
6
8
10
12
14
16
910
18
± % 20
2D 2D5D 10D
C
TBV
*) *) Control valve
5-5-20 - 4
DN 15
DN 20
Diagram TBV
Recommended area: Pos. 3-10
Position Kv
0,5 0,24
10,37
20,63
30,87
41,12
51,39
61,66
71,98
82,34
92,88
10 3,60
T
our
&
A
n
d
ersson re
t
a
i
ns
th
e r
i
g
ht
t
o ma
k
e c
h
anges
t
o
it
s pro
d
uc
t
s an
d
spec
ifi
ca
ti
ons w
ith
ou
t
pr
i
or no
ti
ce.
Recommended area: Pos. 3-10
Position Kv
0,5 0,13
10,21
20,36
30,51
40,65
50,78
60,92
71,07
81,26
91,51
10 1,80