TX7004 Operating Instruction
Following an ALARM Condition
FIRE
Alarm Tone and Red Display
N0001: 02-17 05:32 Panelself Zone-001 Total Fire Alarm Devices
Panel 1 Ground Floor
List of Zones on Fire Alarm Condition –Total Zone: 0001 Total Devices:0001
Fire:0002
Pre-Alarm: 0000
Supervisory: 0000
Fault: 0000
Activation: 0000
000000
0000
!LAST FIRE ALARM ZONE!
Last Fire: 02-17 05:32 Panelself Zone-001 Total Fire Alarm Devices
Panel 1 Ground Floor
FI
Detail
F2
F3
BUZZ
Mute
Evac
Silence
Menu
Commission Status
Level 1-User
Stand-alone
2014-02-17 02:53:37
1. Open the door. LCD screen
displays: The first, and in multiple
alarm condition also the last fire,
time and zone location. Fire LED
turn on steady and corresponding
zone indication.
N0001: 02-17 05:32 Panelself Z0001 L01 D001 ˂Photo w/Heat Detector ˃
General Manager Office
List of Zones on Fire Alarm Condition –Total Zone: 0001 Total Devices:0001
Fire:0002
Pre-Alarm: 0000
Supervisory: 0000
Fault: 0000
Activation: 0000
000000
0000
N0002: 02-17 05:30 Panelself Z0001 L01 D002 ˂MCP ˃
Service Door
!LAST FIRE ALARM ZONE!
Last Fire: 02-17 05:32 Panelself Zone-001 Total Fire Alarm Devices
Panel 1 Ground Floor
FI
Detail
F2
F3
RESET
BUZ
Mute
Evac
Silence
Menu
Commission Status
Level 1-User
Stand-alone
2014-02-17 02:53:37
2. Press “(F1) Detail”button to view
the zone number, device loop,
address, device type and location
3. To view all fire events, press key
▲and▼ (Up and Down cursor to
scroll)
Silencing the panel buzzer and sounder
1. Silence the control panel
Press the “BUZ Mute” button. Display
show “PASSCODE: __” input the code
and press “Enter”
2. Silencing the sounder signal
Press the “Silence” button. Display show
“PASSCODE: __” input the code and
press “Enter” and then SILENCE LED turn
on steady
Resetting the system
When the alarm condition has been cleared,
restore and replace all affected devices in
accordance with the details provided with
each device.
1. Reset the system
In fire mode. Press “RESET” button.
Display show “PASSCODE: ___”
input the code. After reset the display
should shows “NORMAL STATUS”
F1
Detail
BUZ Mute
BUZ Mute
Reset
Reset
F1
Back
TX7004 Operating Instruction
Following FAULT Condition
FAULT
Alarm Tone and Yellow Display
N0001: 02-17 01:11 Panelself Z0001 L01 D001 ˂Photo w/Heat Detector ˃
Loss Communication
General Manager Office
List of Devices on Fault Condition - - - Total Devices: 0002
Pre-Alarm: 0000
Supervisory: 0000
Fault: 0002
Activation: 0000
000000
0000
F1
F2
F3
BUZZ
Mute
Evac
Silence
Menu
Monitoring Status
Level 1-User
Stand-alone
2014-02-17 01:14:37
1. Open the door. LCD screen
displays: The first, and in multiple
alarm condition also the last fault,
time and device details. General
Fault LED turn on steady and
corresponding zone indication is
blinking.
Check the fault, restore or replace the defective
device. Isolate the fault during analysis if
necessary.
Disable the device.
1. On the main menu, press “2 Operation Menu,
Display show “PASSCODE: __” input the
code and press “Enter”
2. On operation menu, press “4 Disable/Enable
Setup, then press “2 Dis/Enable devices by
Address” and then “1 Disable device by
address”.
3. Input the loop and address number, press
Enter and then Disable LED turn on steady
Enable the device.
1. On the main menu, press “2 Operation
Menu, Display show “PASSCODE: __” input
the code and press “Enter”
2. On operation menu, press “4 Disable/Enable
Setup, then press “2 Dis/Enable devices by
Address” and then “2 Enable device by
address”.
3. Input the loop and address number, press
Enter and then Disable LED turn off once it
is confirmed.
BUZ Mute
Fire: 0000
N0002: 02-17 01:13 Panelself Z0001 L01 D002 ˂MCP ˃
Loss Communication
Service Door
Reset
N0001: 02-17 01:11 Panelself Z0001 L01 D001 ˂Photo w/Heat Detector ˃
Loss Communication
General Manager Office
List of Devices on Fault Condition - - - Total Devices: 0002
Pre-Alarm: 0000
Supervisory: 0000
Fault: 0002
Activation: 0000
000000
0000
F1
F2
F3
BUZZ
Mute
Evac
Silence
Menu
Monitoring Status
Level 3- Maintenance
Stand-alone
2014-02-17 01:14:37
2. Silencing the panel buzzer.
Press the “BUZ Mute” button.
Display show “PASSCODE: __”
input the code and press “Enter”
BUZ Mute
Fire: 0000
N0002: 02-17 01:13 Panelself Z0001 L01 D002 ˂MCP ˃
Loss Communication
Service Door
Reset

Other Tanda Security System manuals

Tanda TX7300 User manual

Tanda

Tanda TX7300 User manual

Tanda TX7301 User manual

Tanda

Tanda TX7301 User manual

Popular Security System manuals by other brands

Elmo TRH series user manual

Elmo

Elmo TRH series user manual

UNIONCOMMUNITY UBio-X Iris user guide

UNIONCOMMUNITY

UNIONCOMMUNITY UBio-X Iris user guide

C & K Systems S5010 Using

C & K Systems

C & K Systems S5010 Using

Abus Secvest IP Installation and operating instructions

Abus

Abus Secvest IP Installation and operating instructions

Autostart Redefining the Ultimate Control AS-DSP706 owner's guide

Autostart

Autostart Redefining the Ultimate Control AS-DSP706 owner's guide

Contro l4 Smart Home OS 3 Security guide

Contro l4

Contro l4 Smart Home OS 3 Security guide

KeriSystems Alarm Relay Board installation guide

KeriSystems

KeriSystems Alarm Relay Board installation guide

Abus Terxon LX Administration manual

Abus

Abus Terxon LX Administration manual

Q-See QC40108-818 Quick installation guide

Q-See

Q-See QC40108-818 Quick installation guide

Scantronic 9448+ Installation and user guide

Scantronic

Scantronic 9448+ Installation and user guide

Q-See QSDS14273X quick start guide

Q-See

Q-See QSDS14273X quick start guide

smart home 7307 user manual

smart home

smart home 7307 user manual

Q-See QT17D324SC user manual

Q-See

Q-See QT17D324SC user manual

Paradox DCT10 quick start guide

Paradox

Paradox DCT10 quick start guide

Abus FU2938 installation guide

Abus

Abus FU2938 installation guide

Sonic Alert DS 800 Installation directions

Sonic Alert

Sonic Alert DS 800 Installation directions

Innohome SA102RF user manual

Innohome

Innohome SA102RF user manual

Paradox IP150 user guide

Paradox

Paradox IP150 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.