TCS TCS 3000 User manual

www.tcsmeters.comTotal Control Systems
Catalog Title
Catalog Subtle
Installaon Manual
TCS 3000
ELECTRONIC REGISTER

2
www.tcsmeters.comTotal Control Systems 2
TCS 3000 Installation
Table of Contents
Warning Symbols
CAUTION
Follow the warning instrucons within
the following informaon to avoid
equipment failure, personal injury or
death.
TURN POWER OFF
Before performing any maintenance,
be sure to turn system power o to
avoid any potenal electric spark
FLAMMABLE
Flammable liquids and their vapors
may cause a re or explosion if ignited.
EYE PROTECTION
Pressurized systems may cause hazardous leaks
and spray that may be dangerous for your eyes.
Always wear eye protecon around pressurized
systems and its hazardous liquids.
INJURY
Wear gloves for protecon from hazardous liq-
uids that may cause irritaon or burns.
READ
Read and understand all related manuals thor-
oughly. The Engineering and OIM manuals will
provide the knowledge for all systems, mainte-
nance and operaon procedures. If you have
any quesons, please consult the factory.
WARNING EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE
AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS
WARNING EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR UL/cUL
CLASS 1, DIVISION 2, GROUPS C AND D HAZARDOUS LOCATIONS.
Table of Contents 2
Receipt & Inspecon 3
Noce 3
Introducon 4
System Specicaons 4
Dimensions 5
682 Piston Meter Installaon 6
700 Rotary Meter Installaon 7
Remote Meter Installaon 8
Remote Meter Mounng Dimensions 9
Grounding Strap Installaon 10
Power On Time Relay Installaon 11
Direct Mount Pulser Installaon 12
Test Pulser Installaon 13
Pump Control Installaon 14
Pump Speed Control Installaon 14
Addive Injecon Pump Installaon 15
Electronic Air Eliminator — Float 16
Electronic Air Eliminator — Vibronic 17
LPG 1-Stage Security Valve Installaon 18
LPG 2-Stage Preset Valve Installaon 19
1-Stage Security Valve Installaon 20
2-Stage Preset Valve Installaon 21
Temperature Probe Installaon 22
Temperature Probe Installaon Kits 23
Daisy Chain Communicaon 24
Printer Installaon 25
Printer Installaon Kits 26
Printer Installaon Kits (Connued) 27
Printer Installaon Kits (Connued) 28
Power O Time Relay installaon 29
Radio Modem Installaon 30
Sierra Cellular Modem Installaon 31
Maestro Cellular Modem Installaon 32
Remote Display Installaon 33
1-Channel Communicaon Board Installaon 34
1-Channel Dierenal Pressure (DP) Installaon 35
1-Channel Tank Level Monitor Installaon 36
8-Channel Tank Level & DP Installaon 37
Typical Wiring Diagram 38
Soware Version Upgrade Instrucons 39
Replacement Front Cover Computer Instrucons 40
Parts Schemac 41
Warranty 42

3
TCS 3000 Installation
www.tcsmeters.comTotal Control Systems
Receipt & Inspecon
Upon receipt of register shipment, be sure to inspect the packaging and the register assembly for any damage before
signing the receipt of the shipment. Nofy the delivery company about possible damage and refuse receipt of the ship-
ment.
Registers are individually boxed and are protected with stac resistant packing material. Each package is idened
with the register assembly part number, descripon and serial number. Verify the register model is the correct model,
size, and conguraon as ordered. Contact your distributor if there is any discrepancy or queson.
Register assemblies should be handled with appropriate methods for the size and weight involved. Appropriate cloth-
ing and shoes need to be ulized. Transport the register package to the installaon site with appropriate transporta-
on methods, careful not to damage the register.
Be careful of any loose or protruding staples from the packaging, as they can be very sharp and may potenally cause
injury.
If foam has been used to protect register, carefully remove top foam layer before aempng to remove register as-
sembly from box. Foam packaging maybe formed around the register assembly making it dicult to remove. Do not
li the register assembly by wires or anything other than the metal body of the register. Do not insert objects or cables
into the register unless stated. Removing register assembly from packaging without adhering to these warnings may
cause serious injury to you and/or the register.
Appropriate precauons should be taken regarding any personal, environmental and material compability with the
end use system.
Noce
Total Control Systems (TCS) shall not be liable for technical or editorial errors in this manual or omissions from this
manual. TCS makes no warranes, express or implied, including the implied warranes of merchantability and tness
for a parcular purpose with respect to this manual and, in no event, shall TCS be liable for special or consequenal
damages including, but not limited to, loss of producon, loss of prots, etc.
The contents of this publicaon are presented for informaonal purposes only, and while every eort has been made
to ensure their accuracy, they are not to be construed as warranes or guarantees, expressed or implied, regarding the
products or services described herein or their use or applicability. We reserve the right to modify or improve the de-
signs or specicaons of such products at any me.
TCS does not assume responsibility for the selecon, use or maintenance of any product. Responsibility for proper se-
lecon, use and maintenance of any TCS product remains solely with the purchaser and end-user.
All rights reserved. No part of this work may be reproduced or copied in any form or by any means – graphic, elec-
tronic or mechanical – without rst receiving the wrien permission of Total Control Systems, Fort Wayne, Indiana
USA.

4
www.tcsmeters.comTotal Control Systems 4
TCS 3000 Installation
ELECTRICAL
Power 12 — 24 VDC INPUT
Current 1.4 Amps
Solid State Relays 12/24 Vdc; Passive Solid State
INTERNAL PULSER
Pulse Rao 100:1 PPR; Quadrature
Power 5 Vdc
Hertz 0 — 5000 Hz
EXTERNAL PULSE INPUT
Type Single or Dual Channel (Quadrature)
Power 5 Vdc
ENCLOSURE
Aluminum die cast with epoxy powder coat
Rangs UL/cUL Class 1, Division 2, Group C + D Hazardous Locaons
IP 66 / NEMA 4
Temperature Range - 40 F to 158 F (-40 C to 70 C)
Connecon Ports: Ten (10) 1/2” NPT UL/cUL threaded connecon ports
Oponal ten (10) M20 ATEX threaded connecon ports
Calibraon Seal Opcal switch, password and mechanical seal
Introducon
The TCS 3000 register is a fully integrated custody transfer ow computer that will control all vehicle delivery opera-
ons. The Open Soware Architecture provides the opon of a simple “Pump & Print” delivery or a custom measure-
ment soluon. The TCS 3000 features a 4.5”x 3.5” full color VGA display screen, mulple delivery screens and a backlit
alpha-numeric keypad for the user interface. Available in exible mounng conguraons of 75 or 90 degree displays
for meter mounng, and a remote mounng.
As an ow computer with open soware architecture, there will always be a need to add features to the register as the
industry applicaons evolve. Therefore please be reminded to contact the factory for periodic updates.
The TCS 3000 electronic register is a fully integrated ow computer that will control all delivery operaons. The modu-
lar design and open soware architecture provide you with a tailored system that is expandable for future needs. The
TCS 3000 features a large easy view VGA screen, alpha-numeric keypad and open printer interface for simple “Pump
and Print” deliveries. Soware features oer complete exibility of delivery screen informaon with preset, price/tax,
customizable cket format and password protecon.
Oponal GPS, Bluetooth, Wi-Fi and Cellular capability enables the TCS 3000 to improve your product security and ease
access to your delivery data to reduce your operaon costs. Many addional features are available (mulple product
delivery, addive injecon, density/temperature correcon, mulple valve & pump control, etc.) to enhance your
measurement soluon.
This manual will help guide you with the setup conrmaon and calibraon of the register. Addional informaon will
be provided for wiring instrucon and auxiliary devices to integrate into the register.
System Specicaons

5
TCS 3000 Installation
www.tcsmeters.comTotal Control Systems
The USB0 and USB1 ports are for maintenance only. To access these connectors, power to the unit must be
disconnected and the area known to be free of ignitable gas or equivalent.
COMMUNICATION
Four (4) RS 485 output, 2-wire half duplex, custom protocol; 9600 baud, 8 bit, no parity, 1 stop bit
One (1) RS 232 output, 9600 baud; 8 bit, no parity, 1 stop bit
DIMENSIONS — INCHES (MILLIMETERS)

6
www.tcsmeters.comTotal Control Systems 6
TCS 3000 Installation
Installaon Procedure — TCS 682 Series Meter
Before beginning the installaon of the TCS 3000 register, unpack the enre contents of the packaging in a safe loca-
on where you will not misplace any of the parts. Lay out the parts as they would be installed. This will ensure that
you have all the correct parts for the installaon. Verifying all the necessary parts were included in the shipment in
advance will reduce downme and avoid any wasted preparaon work.
Item Qty TCS 300871
Metric
TCS 300971
NPT
Phillips Pan 6TCS300137 TCS300137
Spring Washer 6TCS300138 TCS300138
Terminal Cover 1TCS300164 TCS300164
7.5 AMP Fuse 1TCS300192 TCS300192
Fuse Holder 1TCS300193 TCS300193
Cable Gland 4TCS300249 TCS300133
USB Fem/Mini Male Cable 1TCS300705 TCS300705
Resistor 1K OHM 2TCS300753 TCS300753
1/4—28 X 3/4 Zinc Bolt 2TCS68004 TCS68004
1/4—28 X 3/4 Drilled Bolt 2TCS68004D TCS68004D
Drive Coupling, 682 1TCS600420 TCS600420
3/64 X 1 Coer Pin 1TCS790091 TCS790091
Installaon Procedure:
1. Remove and put aside the four mounng bolts and any mounng adaptor. Remove the exisng mechanical regis-
ter or electronic register, if applicable. Use a box or container to set old equipment and parts in.
2. Using the sha specic to your installaon, slide the Drive Sha Coupling on the Pulser Sha and align the holes.
Once the holes are aligned insert the Coer Pin and bend the pin ends back around the Drive Coupling.
3. Slide the Drive Coupling onto the Meter Drive Sha.
4. Rotate the TCS 3000 register unl the display is facing in the desired direcon and check to see that the meter
holes align with the holes at the base of the TCS 3000 register.
5. Secure the bolts.
682 Drive Coupling
Coer Pin

7
TCS 3000 Installation
www.tcsmeters.comTotal Control Systems
Installaon Procedure — TCS 700 Series Meter
Before beginning the installaon of the TCS 3000 register, unpack the enre contents of the packaging in a safe loca-
on where you will not misplace any of the parts. Lay out the parts as they would be installed on the truck. This will
ensure that you have all the correct parts for the installaon. Verifying all the necessary parts were included in the
shipment in advance will reduce the truck downme and avoid any wasted truck preparaon work.
Item Qty TCS 300870
Metric
TCS 300970
NPT
Phillips Pan 6TCS300137 TCS300137
Spring Washer 6TCS300138 TCS300138
Terminal Cover 1TCS300164 TCS300164
7.5 AMP Fuse 1TCS300192 TCS300192
Fuse Holder 1TCS300193 TCS300193
Cable Gland 4TCS300244 TCS300133
O-Ring, Cable Gland 4TCS300245 TCS300245
USB Fem/Mini Male Cable 1TCS300705 TCS300705
Resistor 1K OHM 2TCS300753 TCS300753
1/4—28X1 Zinc Bolt 2TCS68013 TCS68013
1/4-28X1 Drilled Bolt 2TCS68013D TCS68013D
3/64 X 1 Coer Pin 1TCS790091 TCS790091
700 Meter Drive Coupling 1TCS790092 TCS790092
Installaon Procedure:
1. Remove and put aside the four mounng bolts and any mounng adaptor. Remove the exisng mechanical regis-
ter or electronic register, if applicable. Use a box or container to set old equipment and parts in.
2. Remove adjuster dust cover plate from the front of the meter. Remove exisng adjuster. Set adjuster dust cover
aside in a box or container where it will not be misplaced. Screw the screws back into meter unit. Noce the type
of vercal drive sha in the meter.
3. Using the sha specic to your installaon, slide the Drive Coupling on the Pulser and align the holes. Once the
holes are aligned insert the Coer Pin and bend the pin ends back around the Drive Coupling.
4. Slide the Drive Coupling onto the Meter Drive Sha.
5. Rotate the TCS 3000 register unl the display is facing in the desired direcon and check to see that the meter
holes align with the holes at the base of the TCS 3000 register.
6. Secure the bolts.
700 Drive Coupling Coer Pin
700 Drive Sha

8
www.tcsmeters.comTotal Control Systems 8
TCS 3000 Installation
Installaon Procedure — 3000 Remote Mount
Before beginning the installaon of the TCS 3000 register, unpack the enre contents of the packaging in a safe loca-
on where you will not misplace any of the parts. Lay out the parts as they would be installed. This will ensure that
you have all the correct parts for the installaon. Verifying all the necessary parts were included in the shipment in
advance will reduce downme and avoid any wasted preparaon work.
Installaon Procedure:
1. Use the Remove Mount Kit to mount the TCS3000 register in your desired locaon.
2. Follow the direcons in the Direct Mount Pulser Manual (TCS900030) to install the Pulser on the meter.
3. Once the Pulser is wired, run the corresponding wire cable into the back of the TCS 3000 register.
4. Insert the pulser wiring through the cable gland. Wire the pulser into the correct pulser locaon on the terminal
board. Leave a small amount of slack on the wiring. Be careful not to leave any bare exposed wiring.
5. Compress the cable gland on the TCS3000 register unl it is snug on the pulser wire.
Item Qty TCS 300877
Metric
TCS 300977
NPT
Phillips Pan 6TCS300137 TCS300137
Spring Washer 6TCS300138 TCS300138
Terminal Cover 1TCS300164 TCS300164
7.5 AMP Fuse 1TCS300192 TCS300192
Fuse Holder 1TCS300193 TCS300193
Cable Gland 4TCS300249 TCS300133
O-Ring, Cable Gland 4TCS300245 TCS300245
USB Fem/Mini Male Cable 1TCS300705 TCS300705
Resistor 1K OHM 2TCS300753 TCS300753
USB Adapter
Fuse Holder
Fuse
Resistors
Cable Glands

9
TCS 3000 Installation
www.tcsmeters.comTotal Control Systems
Installaon Procedure — 3000 Remote Mount
Dimensions—Inches (Millimeters)

10
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — Grounding Strap
Installaon Procedure:
GROUNDING A TRUCK SEAT:
1. Idenfy any adjustable, shock absorbing seat in the truck cab.
These seats will typically have pivot points, hinges, or other me-
chanical design features that make seat adjustments possible.
2. Find an exisng screw or hole near the back of the seat frame,
close to the cab oor. If a hole or screw does not already exist,
drill a 3/8” hole in the seat frame.
3. Aach one end of the ground strap to the seat frame bracket
using the lock washer, at washer and nut provided.
4. Find and exisng hole in the part of the seat frame aached to
the seat cushion above any pivots and adjustments. If a hole or
screw does not already exist, drill a 3/8” hole in the seat frame.
Make sure that there are no interfering pivots, guides, or adjust-
ment mechanisms that could interfere with the ground path
between the seat cushion and the ground strap. If the seat cush-
ion has a wooden base, aach the strap lug to an exisng screw
from the metal bracket directly aached to the wood seat where
the seat fabric is aached to the wood. There must be good
contact between the seat fabric and the ground strap lug.
5. Use the wire es provided with the kit and e o the strap so
that it doesn't interfere with the movement of the seat and is
clear of trac areas in the cab.
6. Check the strap for a good ground connecon. (see right)
Mount ground strap using sup-
plied hardware or an exisng
bolt. Do not use this ground
point if the seat cushion has a
front pivot.
Mount ground strap using sup-
plied hardware or an exisng
bolt.
Bundle excess ground wire using
a wire e.
Checking for good ground connecon along the ground strap:
1. Turn OFF all accessories, including the dome light, to prevent
other currents from distorng the reading.
2. Take a mulmeter and measure the resistance between the
brackets the ground strap bolts are fastened to.
3. If the resistance is less than 3Ω, the system is grounded ade-
quately. If the resistance is sll greater than 3Ω, check for
proper metal to metal contact on both ends of the grounding
strap. Clean any paint, dirt, or oxidaon that may block the
grounding point. If the resistance remains above 3Ω, aach
the ground strap to a dierent point and repeat the process
unl resistance is below 3Ω.
TCS 300597, Grounding Strap Kit
Zip Ties
#8 Grounding Strap
1/4” Hardware

11
TCS 3000 Installation
www.tcsmeters.com
Total Control Systems
Installaon Procedure — Time On Relay
Power On Timing Relay
When installing the TCS 3000 register on delivery tank trucks, it is recommended to use a ming relay for safe startup of the TCS
3000 registraon. Install the TCS 300289 Power On Time Relay from the Accessory Ignion (ACC) to the TCS 3000 register for a
selectable me (Seconds) open of power. This will allow the clean power to the TCS 3000 register during its boot up cycle and limit
exposure to any signicant current draw from charging glow plugs or a low power baery startup.
Installaon Procedure:
1) Wire GND to the Negave side of the Baery. NOTE: a minimum of a 18 gauge wire should be used.
2) Wire ACC (+) and (C) ACC Posive (on the relay), then jumper ACC Posive to the truck ACC (Ignion).
3) Wire N.O. to the (Posive) side of the Terminal Board in the TCS 3000 register.
4) Adjust the Time interval with a small Philips screw driver. Recommended minimum value is 45 seconds.
NOTE: If your wiring a Printer, it should be wired to the N.O. also. This will allow the printer to power up at the same me.
TIME ADJUSTMENT

12
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
GND — GND
+5V — VIN
TAHA1 — CHA
TAHB1 — CHB
5VDC SHUNT
Installaon Procedure — Direct Mount Pulser
Direct Mount Pulser

13
TCS 3000 Installation
www.tcsmeters.com
Total Control Systems
Installaon Procedure — Test Pulser
Prior to pung the liquid handling system into service, the distributor can ulize the TCS 3000 register TEST PULSER to verify that
all Inputs/Outputs are working correctly. The Test Pulser will simulate an actual product delivery without having to pump product
through the meter. Ulize the Test Pulser to check pump and addive injecon pump outputs, air eliminator and exhaust valve
operaon, preset solenoid actuaon, daisy chain communicaon for the modem and printers.

14
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — Pump & Throle
RED
BLACK
Installaon Procedure:
1. Locate the Pump Control (PMP. CRL) posion on the terminal
board.
2. Screw the cable gland into the back of the TCS 3000 register and
ghten into the housing.
3. Run the Pump Control to the onboard computer or programma-
ble logic controller (PLC) wiring through the cable gland. Wire the
air eliminator oat into the correct locaon on the terminal
board. Leave a small amount of slack on the wiring.
4. Compress the cable gland on the TCS3000 register unl it is snug
on the air eliminator oat wiring.
The Pump Control is ulized as a posive output signal for the enre delivery pro-
cess. Providing security pump authorizaon and more accurate deliveries. Some-
mes required to be used with onboard computer systems or programmable logic
controllers (PLC).
BLACK
RED
RED
BLACK
THROTTLE 1
THROTTLE 2
Installaon Procedure:
1. THROTTLE 1: Locate the Pump Starter (PMP START) port on ter-
minal for Throle 1 posive output signal based on Flow Rate.
WARNING: Throle 1 product selecon will override the Addive
Injecon parameter if selected.
2. THROTTLE 2: Locate the Auxillary 1 (AUX 1) port on terminal for
Throle 2 posive output signal based on Flow Rate.
3. For both Throle outputs, wire signal wire to (+) and ground to
(GND).
PUMP CONTROL

15
TCS 3000 Installation
www.tcsmeters.com
Total Control Systems
Installaon Procedure — Addive Injecon Pump
There are two selecons for managing Addive Injecon Pumps; External and Piston.
EXTERNAL: The External funcon for Addive Injecon is to
provide an posive output signal during the enre delivery pro-
cess to manage an external addive injecon pump. The
source power voltage is what you will receive from the terminal
named PMP. START.
NOTE: If using Throle Control 1, this will deacvate the External addive injecon
pump.
Addive Meter: A single or dual channel addive ow meter
can be wired into the ADD. INJ. PULSER terminal to inde-
pendently measure addive volume during a ow rate. Cali-
brate Addive Meter within following PISTON addive selec-
on, then switch back to External.
BLACK
RED
BLACK
RED
GND — GND
+5V — VIN
TAHA2 — CHA
TAHB2 — CHB
PISTON: The Piston funcon for Addive
Injecon is to provide calibrated posive output
signals during the enre delivery process to actuate
an external addive injecon pump. The source
power voltage is what you will receive from the ter-
minal named ADD. INJECTOR VALVE.
Addive Meter: A single or dual channel addive
ow meter can be wired into the ADD. INJ. PULSER
terminal to independently measure addive volume
during a ow rate.
GND — GND
+5V — VIN
TAHA2 — CHA
TAHB2 — CHB
NOTE: Addive Injecon Pump and Valve terminals will not operate in Weights & Measures mode. Calibraon for the PISTON
addive injecon pump and ow meter are required to be performed outside W&M Sengs, then changed within W&M

16
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — Float Electronic Air Eliminator
Installaon Procedure:
1. Locate the air eliminator oat wiring on the metering system.
2. Install the cable gland into the back of the TCS 3000 register
and ghten into the housing.
3. Run the air eliminator oat wiring through the cable gland.
Wire the air eliminator oat into the Air Eliminator (AIR
ELIMINAT.) terminal on the board. Leave a small amount of
slack on the wiring.
4. Compress the cable gland on the TCS3000 register unl it is
snug on the air eliminator oat wiring.
5. Locate the air eliminator solenoid wiring on the metering
system.
6. Install the cable gland into the back of the TCS 3000 register
and ghten into the housing.
7. Run the air eliminator solenoid wiring through the cable
gland. Wire the air eliminator solenoid into the Auxiliary Re-
lay 2 (AUX 2) on the terminal board. Leave a small amount of
slack on the wiring.
8. Compress the cable gland on the TCS 3000 register unl it is
snug on the air eliminator solenoid wiring.
NOTE: Do not run mulple cables through a single cable
Air Eliminator Solenoid
Air Eliminator Float Wiring
RED
BLACK
1/4” NPT Exhaust Vent

17
TCS 3000 Installation
www.tcsmeters.com
Total Control Systems
Installaon Procedure — Vibronic Electronic Air Eliminator
Installaon Procedure:
1. Connect Independent +24VDC to Terminal Block L1 in the Vibronic Sensor
2. Connect Terminal Block 7 to “GND” and Terminal Block 8 to “Air Elim.” under Air Eliminator Secon of the TCS
3000 register.
3. Set the Dip Switch on the Vibronic Sensor to the MIN Posion.
4. Wire Air Eliminator Solenoid as normal.

18
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — LPG 1-Stage Security Valve
Installaon Procedure:
1. Using the bolts and gasket provided, install the 757 LPG valve on the outlet (downstream) side of the meter.
2. Follow the instrucons provided with the valve for wiring the solenoid.
3. Mount the 3 Way Valve and threaded ng directly to the TCS 3000 register and follow the instrucons provided
with the Valve.*Note: Use Correct Thread Sealant*
4. Once the solenoid is wired, run the corresponding wire as pictured using a minimum of 18 gauge shielded cable
into the back of the TCS 3000 register. The 3 Way valve will be wired into Solenoid 2 on the terminal board.
5. TCS 3000 register product programming for Valve Type should be set to Single Stage.
*When Calibrang the Unit Set Up Valve Type as 1001*
GREEN
BLACK
BLACK
S2 – Fast Flow
Solenoid Valve

19
TCS 3000 Installation
www.tcsmeters.com
Total Control Systems
Installaon Procedure — LPG 2-Stage Preset Valve
GREEN
BLACK
BLACK
S2 -Slow Flow Shut
O Solenoid Valve
Installaon Procedure:
1. Using the bolts and gasket provided, install the 757 LPG valve on the outlet (downstream) side of the meter.
2. Follow the instrucons provided with the valve for wiring the solenoid.
3. Mount the 3 Way Valve directly to the TCS3000 register and follow the instrucons provided with the Valve
*Note: Use Correct Thread Sealant*
4. Once the solenoid is wired, run the corresponding wire as pictured using a minimum of 18 gauge shielded cable
into the back of the TCS 3000 register. The 3-Way Valve will be wired into Solenoid 1 (S1) on the terminal board
and the Slow Flow Bypass Valve will be wired into Solenoid 2 (S2).
5. Insert the solenoid wiring into the cable gland. Wire the solenoid into the correct solenoid locaon on the termi-
nal board. Leave a small amount of slack on the wiring.
6. Compress the cable gland on the TCS 3000 register unl it is snug on the solenoid wire.
7. TCS 3000 register product programming for Valve Type should be set to Dual Stage.
*When Calibrang the Unit Set Up Valve Type as 1001*
S1 – Fast Flow
Solenoid Valve

20
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — 1-Stage Security Valve
Installaon Procedure:
1. Using the bolts and gasket provided, install the 655 Diaphragm or
755 Piston Valve on the outlet (downstream) side of the meter.
2. Wire the solenoid valve to Solenoid 2 (S2) for a Single Stage oper-
aon
3. Once the solenoid is wired, run the corresponding wire as pic-
tured using a minimum of 18 gauge shielded cable into the back
of the TCS 3000 register.
4. Insert the solenoid wiring into the cable gland. Wire the solenoid
into the correct solenoid locaon on the terminal board. Leave a
small amount of slack on the wiring.
5. Compress the cable gland on the TCS3000 register unl it is snug
on the solenoid wire.
655-21 Diaphragm 2” Valve 755-21 Piston 2” Valve 755-31 Diaphragm 3” Valve
*When Calibrang the Unit Set Up Valve Type as 1101*
S2
S2
S2