Power Temperature Controllers
TECA 1-888-TECA-USA (832-2872) www.thermoelectric.com
MODEL PART NOTES TEMP @ TEMP @ T1-T2 RESET RESET TEMP @ T3 OPERATING SWITCHING SWITCHING
NUMBER NUMBER T1 °C T2 °C (MAX) °C (TYP) °C°C VOLTAGE VOLTAGE CURRENT MAX.
TC-6F 6F-00A-00-000 No Relay 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On NA NA NA
TC-6F-AC 6F-03T-00-000 VAC Version 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 85-250 VAC 24-280 VAC 10
TC-6F-DC 6F-43D-00-000 12/24 VDC 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 12/24 VDC 0-100 VDC 20 ADC
TC-6F-DC 6F-33D-00-000 48 VDC 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 48 VDC 0-100 VDC 20 ADC
MODEL PART NOTES COOL HEAT RESET RESET OPERATING SWITCHING SWITCHING H-BRIDGE
NUMBER NUMBER TEMP. °C TEMP. °C (MAX) °C (TYP) °C VOLTAGE VOLTAGE CURRENT MAX. RELAYS
TC-3F-AC 3F-04R-00-000 VAC Version 35 +/- 5 15 +/- 5 6.5 3 85-280 VAC 24-280 VAC 10 AMPS N/A
TC-3F-DC 3F-44G-00-000 12/24 VDC 35 +/- 5 15 +/- 5 6.5 3 3.5-32 VDC 0-100 VDC 20 ADC N/A
TC-3F-DC 3F-44P-00-000 12/24 VDC 35 +/- 5 15 +/- 5 6.5 3 3.5-32 VDC 0-100 VDC 20 ADC Solid State
Model TC-6F (Cool Only) thermostat is designed using two temperature power switches in conjunction with a solid state relay. A three position
switch is provided to adjust temperature settings.
Model TC-3F (Heat/Cool) thermostat incorporates the same technology as the TC-6F. It contains a single setting each for both heating and
cooling as referenced below:
TC-1F POWER TEMPERATURE SWITCHES
Models TC-1F power temperature controller, with small tolerance and reset differential, are
the simplest and most cost effective way to control a cooling or heating device (VAC or VDC)
without a need for a relay. For circuits that have higher current draw simply use them in
conjunction with a solid state relay.
TC-6F COOL ONLY
TC-3F HEAT AND COOL
Part Numbers:
Mode Part Number Note
Cool TC-1C-XX switch closes on temperature rise
Heat TC-1H-XX switch closes on temperature drop
XX: Specify temperatures 20 °C, 25 °C, 30 °C, 35 °C for cool mode
and 10°C, 15 °C for heat mode
Example: TC-1C-20 and TC-1H-10
VOLTAGE CURRENT SET POINT T RESET
AMPS OLERANCE °CDIFFERENTIAL °C
125 VAC 2 +/- 3 3 - 6
250 VAC 1.3 +/- 3 3 - 6
12 VDC 2 +/- 3 3 - 6
24 VDC 1.3 +/- 3 3 - 6 Dimensions: Inches [Millimeters]
MODEL PART NOTES COOL HX HEAT RESET RESET OPERATING SWITCHING SWITCHING H-BRIDGE
NUMBER NUMBER TEMP. °C TEMP. °C TEMP. °C (MAX) °C (TYP) °C VOLTAGE VOLTAGE CURRENT MAX. RELAYS
TC-7F-DC 7F-24G-00-000 24 VDC 35 +/- 3 25 +/- 3 10 +/- 3 6.5 3 24 VDC 24 VDC 20 ADC N/A
TC-7F-DC 7F-24O-00-001 24 VDC 35 +/-3 25 +/-3 10 +/-3 6.5 3 24 VDC 24 VDC 12 ADC Solid State
TC-7F-DC 7F-24S-00-000 12 VDC 35 +/-3 25 +/-3 10 +/-3 6.5 3 12 VDC 12 VDC 20 ADC Solid State/Mechanical
TC-7F-DC 7F-24T-00-000 24 VDC 35 +/-3 25 +/-3 10 +/-3 6.5 3 24 VDC 24 VDC 20 ADC Solid State/Mechanical
TC-7F-DC 7F-24U-00-000 48 VDC 35 +/-3 25 +/-3 10 +/-3 6.5 3 48 VDC 48 VDC 20 ADC Solid State/Mechanical
Model TC-7F (Heat/Cool) thermostat incorporates the same technology as the TC-3F. It contains a single setting each for both heating and
cooling and a heat exchanger mode (ECO-Mode).
TC-7F HEAT/COOL WITH ECO-MODE
TC-4F COOL ONLY WITH ECO-MODE
Model TC-4F is simillar to TC-1F plus it has a 2nd power switch for heat exchanger mode (ECO-Mode). The active cool set point for TC-4F is 35 °C
and for heat exchanger mode (ECO-Mode) is 25 °C.
MODEL PART NOTES HX COOL RESET RESET OPERATING SWITCHING ACTIVE MODE ECO-MODE
NUMBER NUMBER TEMP. °C TEMP. °C (MAX) °C (TYP) °C VOLTAGE VOLTAGE SWITCHING SWITCHING
CURRENT MAX. CURRENT
TC-4F-DC 4F-24C-00-000 12/24/48 VDC 25 +/- 3 35 +/- 3 6.5 3 12/24/24 VDC 0-100 VDC 12 ADC 1.3 ADC
TC-4F-DC 4F-24D-00-000 12/24/48 VDC 25 +/- 3 35 +/- 3 6.5 3 12/24/48 VDC 0-100 VDC 20 ADC 1.3 ADC
TC-4F-DC 4F-24E-00-000 12/24/48 VDC 25 +/- 3 35 +/- 3 6.5 3 12/24/48 VDC 0-100 VDC 40 ADC 1.3 ADC
For custom variations of any of the controls, contact TECA.