manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tektronix
  6. •
  7. Measuring Instrument
  8. •
  9. Tektronix P8018 User manual

Tektronix P8018 User manual

Other Tektronix Measuring Instrument manuals

Tektronix AM503S User manual

Tektronix

Tektronix AM503S User manual

Tektronix RSA6100A Series User manual

Tektronix

Tektronix RSA6100A Series User manual

Tektronix DSA8300 Manual

Tektronix

Tektronix DSA8300 Manual

Tektronix Keithley SourceMeter 2410 User manual

Tektronix

Tektronix Keithley SourceMeter 2410 User manual

Tektronix KEITHLEY 3765 User manual

Tektronix

Tektronix KEITHLEY 3765 User manual

Tektronix TLA6402 Installation and maintenance instructions

Tektronix

Tektronix TLA6402 Installation and maintenance instructions

Tektronix KEITHLEY 4200A-SCS-PKB User manual

Tektronix

Tektronix KEITHLEY 4200A-SCS-PKB User manual

Tektronix MTS415 User manual

Tektronix

Tektronix MTS415 User manual

Tektronix Keithley 2651A User manual

Tektronix

Tektronix Keithley 2651A User manual

Tektronix DL-11 DELAY LINE User manual

Tektronix

Tektronix DL-11 DELAY LINE User manual

Tektronix Keithley 7711 User manual

Tektronix

Tektronix Keithley 7711 User manual

Tektronix RSA306 Manual

Tektronix

Tektronix RSA306 Manual

Tektronix RSA306 Use and care manual

Tektronix

Tektronix RSA306 Use and care manual

Tektronix PQA600C Quick start guide

Tektronix

Tektronix PQA600C Quick start guide

Tektronix TLA5000B Series Installation and maintenance instructions

Tektronix

Tektronix TLA5000B Series Installation and maintenance instructions

Tektronix 1S2 User manual

Tektronix

Tektronix 1S2 User manual

Tektronix SPECMON3 User manual

Tektronix

Tektronix SPECMON3 User manual

Tektronix 6 series User manual

Tektronix

Tektronix 6 series User manual

Tektronix RSA3408A User manual

Tektronix

Tektronix RSA3408A User manual

Tektronix ECO8000 Series User manual

Tektronix

Tektronix ECO8000 Series User manual

Tektronix RSA6120A series Manual

Tektronix

Tektronix RSA6120A series Manual

Tektronix RSA3303A User manual

Tektronix

Tektronix RSA3303A User manual

Tektronix CM-9930 User manual

Tektronix

Tektronix CM-9930 User manual

Tektronix 7D01 User manual

Tektronix

Tektronix 7D01 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Copyright Tektronix, Inc.
P8018 Handheld TDR Probe
Instructions
071-1318-00
www.tektronix.com
Safety Summary
To avoid potential hazards, use this product only
as specified.
To avoid fire or personal injury
Ground the product. This product is indirectly
grounded through the grounding conductor of the
mainframe power cord. To avoid electric shock,
the grounding conductor must be connected to
earth ground. Before making connections to the
input or output terminals of the product, ensure
that the product is properly grounded.
Connect and disconnect properly. Do not connect or
disconnect probes or test leads while they are
connected to a voltage source.
Observe all terminal ratings. To avoid fire or shock
hazard, observe all ratings and markings on the
product. Consult the host instrument documenta-
tion for further ratings information before making
connections to the host instrument.
Do not apply a potential to any terminal, including
the common terminal, that exceeds the maximum
rating of that terminal.
Do not operate with suspected failures. If you
suspect there is damage to this product, have it
inspected by qualified service personnel.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Safety symbols on the product
CAUTION
Refer to Product Manual
Product Description
The P8018 is a handheld passive probe with a
50 Ωinput impedance. The P8018 comes standard
with a one meter SMA male-to-male cable
assembly that interfaces with an 80A02 EOS/ESD
Protection Module or other SMA connectable
input.
Figure 1: P8018 handheld TDR probe
The P8018 probe is especially designed to be used
with the Tektronix 80A02 EOS/ESD Protection
Module. Together, they protect sensitive
instrument-input stages, such as the sampling
bridge of Tektronix electrical sampling modules,
from electro-overstress (EOS) and electro static
discharge (ESD) damage due to static charges
stored in the device under test (DUT).The P8018
probe can also be used as a stand-alone,
high-bandwidth probe that is usable with any
SMA connectable instrument.
The P8018 provides a unique pressure-actuating
probe tip that switches between DUT
static-discharging protective mode and
engaged-measurement mode.
Using the Probe
Connector Care
Use extra care when attaching or removing the
cable from SMA connectors. Turn only the nut,
not the cable. When attaching the cable, align the
connectors carefully before turning the nut. Use
light finger pressure to make this initial
connection. Then tighten the nut lightly with a
wrench. Ideally, the SMA connectors should be
tightened to 56 N-cm (5 in-lb) with a torque
wrench.
Probing Technique
The probe tip and grounding clip are designed to
probe printed circuit boards (PCB) that
incorporate ground reference points next to the
signal measurement point. This is to allow the
probe tip to be inserted into a PCB through-hole
test point while the ground clip contacts the
ground reference point.
To achieve the specified bandwidth, the ground
clip must be trimmed to the shortest length
possible for probing the PCB. See Figure 2 for
proper probing technique and ground clip
trimming.
Ground clip
contact trimmed as
short as possible
Probe tip through PCB
test point via hole
Ground clip
installed on
probe
PCB
Figure 2: PCB probing and grounding technique
These instructions describe the operation of the
P8018 probe connected to a Tektronix 80A02
protection module which is then connected to an
instrument to be protected such as a Tektronix
80E04 or SD24 electrical TDR sampling module.
Specifications
Table 1: Environmental and mechanical
Characteristic Specification
Probe dimensions
Length 125 mm (4.94 in)
Height 27 mm (1.06in)
Width 16 mm (0.64 in)
Weight (probe only) 0.054 kg (0.12 lbs)
Altitude
Operating 3,048 m (10,000 ft)
Non-operating 12,190 m (40,000 ft)
Ambient temperature
Operating --15 _C to +55 _C(+5_Fto
+131 _F)
Non-operating -- 6 2 _C to +85 _C(--80_F
to +185 _F)
Humidity
Operating 20% to 80% relative
humidity with a maximum
wet bulb temperature of
+29 _C at or below +40 _C,
non-condensing. (Upper
limit derates to 45% relative
humidity at +40 _C.)
Non-operating 5% to 90% relative humidity
with a maximum wet bulb
temperature of +29 _Cator
below +60 _C,
non-condensing. (Upper
limit derates to 20% relative
humidity at +60 _C.)
*P071131800*
071131800
Copyright Tektronix, Inc.
Table 2: Electrical
Characteristic Specification
Probe impedance 50 Ω+±2%
Attenuation 1X
RF input connector Precision 26 GHz SMA
female connector
Control signal connector
type
Audio mono phone mini-jack
Analog bandwidth
Probe head <3 dB insertion loss, DC to
20 GHz
Cable DC to 20 GHz
Probe fall time
(measured with 80E04 or
SD24 TDR modules)
<38ps
Typical reflected TDR fall
time<28ps
Probe delay 1 ns typical from the
connector end to the probe
tip
This is a stable impedance
section which can be
calibrated and used as a
reference point.
Maximum voltage input ±5.0 V
Module activation probe
pressure
200 to 260 grams
Accessories
The P8018 probe includes the following items:
SSpecial 1 meter SMA cable
with a parallel control line) 174-4879-xx
S20 ground clips 016-1936-xx
WARRANTY SUMMARY
Tektronix warrants that the products that it
manufactures and sells will be free from defects in
materials and workmanship for a period of one (1)
year from the date of shipment. If a product
proves defective within the respective period,
Tektronix will provide repair or replacement as
described in the complete warranty statement.
To arrange for service or obtain a copy of the
complete warranty statement, please contact your
nearest Tektronix sales and service office.
EXCEPT AS PROVIDED IN THIS SUMMARY
OR THE APPLICABLE WARRANTY
STATEMENT, TEKTRONIX MAKES NO
WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. IN NO EVENT
SHALL TEKTRONIX BE LIABLE FOR
INDIRECT, SPECIAL OR CONSEQUENTIAL
DAMAGES.