Powering
NOTE! To reduce the risk of electric shock, do not remove the
shielding cover of the power supply unit if it is connected. All
electrical installations must be carried out by authorized and
competent technicians in accordance with the national or regional
electrical regulations.
Common precautions:
•The CX3 amplifier is intended for installation in restricted access locations
(dedicated equipment rooms, equipment closet, or the like)
•Operate the device only on the specified supply voltage.
•The CX3 must never be operated without its power supply unit shielding
cover.
•The CX3 has no separate power switch thus the power plug must be easily
accessible.
•Disconnect the power cord by the connector only. Never pull on the cable
portion of the power cord.
•Do not place or drop heavy or sharp-edged objects on the power cord.
•The power must be disconnected when installing or removing the CX3.
Additional safety requirements for Norway and Sweden:
•Equipment connected to the protective earthing of the building installation
through the mains connection or through other equipment with a connection
to protective earthing and to a cable distribution system using coaxial cable,
may in some circumstances create a fire hazard. Connection to a cable
distribution system must be provided through a device providing electrical
isolation below a certain frequency range (galvanic isolator, see EN 60728-
11).
The CX3 is available either with a remote or local powering options. The
following subsections describe the differences.
CX3 with remote powering: (27...65 V AC)
If CX3 is a remotely powered, ensure that the power cord entry port is plugged.
The supply voltage of the remote powered CX3 (27...65 V AC) is supplied via
coaxial cables. Feed through capacity is max. 7 A / port. On delivery, RF ports
are provided with fuses.
CX3 with local powering: (205…255 V AC)
The locally powered CX3 is connected to the mains voltage of 205…255 V AC
via its own power cord. The power supply unit is double shielded and does not
require separate grounding. However, ensure that the housing of the CX3 is
properly connected to the earth in order to meet safety requirements. Proper
grounding will also improve protection from the effects of interference and thus
increase the overall reliability of the system.