TEMPRACAM Basic User manual

Table of Contents
Table of Contents
ProductOverview ................................................3
Features .................................................4
Introduction .....................................................4
Safety Cautions .................................................7
Statement .......................................................7
Mobile Host Install ...............................................9
Infrared Image Settings..........................................21-22
Visible Light Image Settings ....................................23
Blind Area Settings ............................................24
Temperature Compensation ....................................25
Double Light Calibration .......................................26
Black Body Conguration ......................................27
Alarm Conguration .......................................28-29
Local System Settings .........................................30
Black Stand Install ..............................................10
DeviceInstallation ...............................................9
Fixing&Positioning ..............................................12
SoftwareInstallation .............................................13
UsingtheSoftware ..............................................14
Real-TimePreview ..............................................15
InterfaceOverview ............................................16-17
DeviceManagement ..........................................18-19
DeviceSettings .................................................20
ImageSettings .................................................21
RecordQuery&Statistics .....................................31-33
DatabaseManagement .......................................34-37
CautionsforUse ................................................38
DeviceOutline ...................................................8
Specications ....................................................5
Connections .....................................................6

Introduction
Features:
Page 4 | Introduction
TEMPRACAM™Basic is a new-generation AI-powered infrared thermal
imaging body camera. The system features contact-free, retention-free and
multi-person temperature measurement in real-time, while integrating the
functions of multi-target face detection, face-to-face database comparison,
and rapid screening of temperatures in high-density crowds.
Our integrated AI software built into the Basic model can detect up to 30
independent temperatures in sequence. Including face alarm detection, data
comparison, and real time face capture.
TEMPRACAM™Basic also includes access to our database management
software, so you can track statistics and stored information from the thermal
imaging camera over time.
• Integrated AI chip, embedded with better thermal resistances for hot and cold environments.
• High-Definition 2 megapixel low illumination, wide dynamic range network camera.
• Covers a temperature measurement range of 68°F-122°F from a distance of 3-10 meters.
• Video recording functions.
• Provides real-time dynamic thermal images, which can render multi-objective measurements.
• Supports multi-target face detection, with automatic capture.
• Supports LED and LCD monitor extensions.
• Supports RFID card / ID reader options.
• Automatic temperature correction with the high precision temperature sensor.
• Automatic temperature warnings.
• Built for year round work - indoor and outdoor.
• Automatic data tracking and reports, which can formulate insights on flow rate of the current
day, time, and temperature hot spots.
• No physical contact required.
• Turnkey (includes software & hardware)
TEMPRACAM | BASIC

TEMPRACAM | BASIC
Specications
Page 5 | Specications
Thermal Camera Specications
Resolution 1920 x 1080
Sensor 200M CMOS Ultra Low-light Camera
Detection distance 3-10 ft
Temp detection type Automatic
Temp detection range 65°F - 120°F
Temp detection accuracy Within (+/-) .3°F
Measurement speed ≤ 0.2ms
Operation Specication
Use scenarios Indoor & Outdoor
Interface & Power Specications
Connection RJ45
Consumption <15 W
Voltage DC 12V
Size System dimensions 150 x 120 x 90 (mm)
Weight System weight 3lbs (approx 1.5KG)
Temperature Working temperature (-4°)F - 120°F

Page 7 | Statement & Safety
TEMPRACAM | BASIC
Statement
Safety Cautions:
• When installing the device, please be certain it is done only by qualified personnel.
• This device must be installed in an environment with lightning protection measures.
• Please do not touch the lens, this will protect the lens from any damage or contamination.
• Pay attention to prevent the lens from any damage, scratches, or abrasions.
• The infrared thermal imaging module contains a highly sensitive thermal sensor; Do not the
lens directly at substantial radiation sources (e.g.the sun, direct or reflected laser beam)
under any circumstances (power on or power off). It will cause permanent damage to the
infrared thermal imaging module.
• This is a precise electronic device. Please handle with care in utilization, storage and
transportation to prevent the device from being crushed, falling from a high place or other
possible hazards.
• During transportation and storage, the ambient temperature should not be less than -13 F/ -
25. Please use the original packing box during transportation.
• Before starting up the device, ensure that the power supply is connected properly. An
incorrectly connected power supply may damage the device.
• Do not apply pressure to the power cable, nor put the device in any place where the power
cable is easily accessible.
• The contents herein will be updated from time to time and dded to the
newly revised manual without notice.
• This manual may contain technical inaccuracies or printing errors.

Device Installation
TEMPRACAM | BASIC
Page 9 | Device Installation
Mobile Station Host Installation
Take out the host bracket in the accessory, Insert the host bracket into the bracket port on the
mobile station through the entire mobile station case until reaching the bottom. Fix the
bracket with screws as shown below.
Take out the host and universal joint from the accessories, and install them as shown below. After
installation, fix the host on host bracket. Finally, connect the power cable and network cable.
Take out the power adapter from the ancillaries, and insert the power cable through the host
bracket from bottom to top. Take out the network cable from the ancillary and insert through
the host bracket from top to bottom. (When threading, adjust the length of the bracket to
the shortest position in advance)
Retaining
Screw
Retaining Screw
Upper & Lower Angle Adjustment
Host Install Base
Upper Cable Entry
Lifting Rotary
Switch

Device Installation
TEMPRACAM | BASIC
Page 10 | Black Stand Installation | Pt. 1
Black Stand Installation
Open the bottom supporting seat of tripod supporting the stand and place on the ground, as
shown below.
Take out the stand in the ancillary, and align the screw holes at the bottom (as shown below) with
the ¼” connecting screw head on top of the tripod. Rotate to fasten the camera body.

Adjust the height of the expansion links of the tripod, and fasten the locking module, as shown
below.
The middle black body bracket is about 3-5 meters from the mobile station, and the black body
position is adjusted to the upper right or left corner of the infrared image.
Device Installation
TEMPRACAM | BASIC
Black Stand Installation (Part 2)
Locking Module 1
Connecting
Screw
Locking Module 2
Page 11 | Black Stand Installation | Pt. 2

Software Installation
TEMPRACAM | BASIC
Operating System: Win7 / Win10
CPU: Intel Core i5 and above; 3.1GHtz; Dual Core and above
Hard Disk: 2TB and above
RAM: 4GB and above
Recommended Minimum Resolution: 1920x1080
Display: 22 inch and above - widescreen recommended
Recommended Computer Specifications
Installing the Software:
Step 1: Click Next.
Step 3: Wait for install to finish. Step 3: Click finish.
Step 2: Click Install.
Page 13 | Software Installation
To download the software please visit tempracam.com/pages/support

Using the Software
TEMPRACAM | BASIC
At the completion of the installing the software, double click the camera icon on your desktop to
launch the application.
1 2 3 4 5 6
1Real-time Preview
Provide real-time image preview, with face large image rolling
and temperature measurement value displayed on the left
side, and current-day statistics on the right side.
2Device Management Provide device adding, modifying, removing and start-up
function.
3Temperature Measuring Conguration
Provide OSD information, blind zone, temp compensation &
correction, double light position calibration, black body
setting, and alarm conguration.
4Record & Query Provide searching and playback functions of image & video
records.
5Statistical Graph
Automatically generate monitoring statistical bar chart
according to the temperature measurement data of the day
and week.
6Face Database Management Provide face database information input and upload host
functions.
Page 14 | Using the Software

1. Add device correctly in “Device Manager”, “Start up Device” after selecting device to start
preview.
2. Set the black body position in “Temperature Measurement Configuration” > “Black Body
Configuration”.
3. Calibrate the double light position in “Temperature Measurement Configuration” > “Double
Light Calibration”
4. Synchronize time.
5. Set the temperature correction in “Temperature Measurement Compensation”
The above steps are key operations.
At the completion of the above settings, the main interface displays the real-time preview effect,
providing visible, and infrared real-time monitoring. Local video capture is also available with the
captured image displayed on the left side, and current day flow rate & temperature statistics
being displayed on the right.
Real-time Preview
TEMPRACAM | BASIC
Configuration Wizard before Real-time Preview
Page 15 | Real-time Preview

Interface Overview
TEMPRACAM | BASIC
Provide infrared and visible light, real-time video monitoring, and display the face detection
frame including the highest temperature stats. Supports multiple people for simultaneous
scanning.
Real Time Monitoring
When the detection reads the preset temperature alert value, the system will capture the visible
and infrared images automatically and trigger the sound alarm.
Warning Capture
Manually capture images by clicking. Each click will save an infrared and visible light image
simultaneously. Default image saving path: D:\DM_Picture or C:\DM_Picture. This path can be
modified through the “image path” in “Temperature Measurement Configuration” > “System
Settings”
Manual Capture
Switch the indicator status to face mode. Display when detecting normal face temperature, when
detecting high temperature, and when failed to detect any face.
Detecting Indicator
Automatically display scrolling panoramas of large face captures on the left side. Display up to 11
large face images simultaneously.
Scrolling Display of Large Face Image
Page 16 | Interface Overview

Click the manual video recording button to begin. Infrared and visible light can be recorded
simultaneously. To stop recording, click the manual record button again.
Manual Video Recording
Generate various bar charts automatically according to the daily / weekly real-time temperature
measurement data. Data can display real-time visitor flow rate stats, current-day population
trend, the latest week high temperature trend, and the population distribution in each
temperature segment. The image below can be viewed in the “statistical chart” interface in the
menu.
Statistical Chart
Interface Overview
TEMPRACAM | BASIC
Page 17 | Interface Overview | Pt. 2

Device Management
TEMPRACAM | BASIC
If there is no device for the first installation by default, which is configured by “Device
Management” > Add Device > Device Information Configuration > Add Device
At the completion of the device information configuration, click “Start up Device” to
automatically open the monitoring screen in the main interface “Real-time Preview”.
• Name: Enter custom device name
• IP Addresses and Port: The factory default IP is 192.168.1.102, and the default port is 5000
• Users may modify IP addresses and gateway of network parameters via web pages,
to ensure that the IP addresses of the configured device and the connected
computer are in the same network segment.
• Username and Password: Enter the factory default username and password of the device in
the configuration interface.
• Username (admin) Password (Admin123) [Case Sensitive]
• Remark: Please ensure to enter the “remark” information of the device as the device ID
How to Add a Device
Page 18 | Device Management

Select the device in the device list column and select “Delete Device”. As shown below:
How to Remove a Device
Device Management
TEMPRACAM | BASIC
Page 19 | Device Management | Pt. 2
When adding multiple devices, select the device in the device list column. To switch monitoring
screen, select start up device and display the preview screen in “real-time preview”
Start Up Device

Device Settings
TEMPRACAM | BASIC
Page 20 | Device Management | Pt. 3
Temperature Measuring Configuration
1Image Settings
Infrared color mode selection, surveillance video OSD information,
time synchronization and device calibration functions. Visibile light
video brightness, contrast, chroma, saturation and other video
settings.
2Blind Settings For interference with temperature exceeding high temp preset,
set blind zone to prevent false alarm.
3Temperature Compensation Provides temperature compensation & correction functions.
4Double Light Calibration Provides double light lens for horizontal and vertical angle
positions.
5Black Body Calibration Provides black body position, temperature and radiance settings.
6Alarm Conguration
Provide alarm enabling, alarm temperature, temperature
measuring range, alarm mode, alarm interval, temperature
measuring frame number settings and audio functions.
7System Settings Local video, image capture path and saving settings. Language
switch and version number can be found here.
Table of contents