TESTO 865 Manual

testo 865, 868, 871, 872 - Thermal Imager
Short instructions
In order to be able to establish a connection via Bluetooth, you need a
tablet or smartphone with the Testo “Thermography” App installed on it.
These short instructions describe the basic operating steps. Please refer
to the instruction manual to find out how to handle the product safely
and for detailed information.
Short
instructions
Instruction
manual
Pocket
Guide
Thermography
V
ideos
All manuals and user guides at all-guides.com
all-guides.com
Element Function
1 Display Displays infrared and real images (except
testo 865), menus and functions
2 Interface terminal Contains micro USB interface for power supply
and connection to the computer
3 - key
- Esc key
- Switch camera on and off
- Cancel action
4 - OK key
- Joystick
- Open menu, select function, confirm setting
- Navigate within the menu, highlight function,
select colour palette
5 Quick select key
Opens the function assigned to the quick select
key; the icon for the selected function is
displayed bottom right
6 Infrared camera lens;
protective cap
Takes infrared images; protects the lens
7 Digital camera
(except testo 865)
Takes real images
8 Laser Marking the measuring point (only testo 872)
9 Trigger Saves the displayed image
10 Battery compartment Contains the rechargeable battery
All manuals and user guides at all-guides.com
Switching the camera on/off
1 - Remove the protective cap from the lens (6).
2 - Switching on: press (3).
- Switching off: press and hold down (3).
To ensure measuring accuracy, the camera performs automatic zeroing
approx. every 60 s. You will hear a “click” and the image freezes briefly.
Getting to know the menu
1 - Press OK (4) to open the menu.
2 - Move joystick (4) up/down to highlight a function (an orange box
appears around it).
3 - Press OK (4) to select the function.
3.1 - Move the joystick (4) right to open the sub-menu (indicated
with ►).
Saving an image
1 - Press the trigger (8).

The infrared image is saved automatically.
testo 868, 871 and 872: irrespective of the selected image type, an
infrared image is always saved with the attached real image.
If a higher resolution is required: In the menu, select the
SuperResolution function under configuration (optional function).
@More information can be found in the instruction manual.
All manuals and user guides at all-guides.com
Displaying and deleting images
1 - Select image gallery function. To do this, see Getting to know
the menu.
2 - Display image: Move joystick (4) left/right/up/down to select the
image, then press OK (4).
3 - Press (5) to delete the image.
Setting emissivity
Function is only available if the infrared image type has been selected.
The emissivity describes the capability of a body to emit thermal
radiation. For correct measurement results, the emissivity can be set
according to the specific material.
With ε-Assist, the emissivity and reflected temperature are
automatically detected.
RTC (Reflected Temperature Compensation) is a correction value for
thermal radiation through other objects.
@More information can be found in the instruction manual and the
pocket guide.
1 - Select the emissivity function. To do this, see Getting to know
the menu.
2 - Move joystick (4) up/down to highlight the required material, then
press OK (4).
Setting measurement
Function is only available if the infrared image type has been selected.
1 - Open the measurement submenu. To do this, see Getting to
know the menu.

The submenu with measurement opens:
•Pixel mark:
oSingle point measurement: the temperature measuring
point in the centre of the image is marked with white
crosshairs and the value is displayed. In saved images,
the crosshairs can be moved using the joystick in order to
read the value of other measuring points.
All manuals and user guides at all-guides.com
oColdspot, hotspot: the lowest or highest temperature
measuring point is marked with blue or red crosshairs and
the value is displayed.
•Min/Max on Area (testo 872): the minimum, maximum and
mean values for a selected area are displayed.
•Measurement range: temperature range in which measuring
values are displayed (for information).
•Differential temperature: identifies the difference between two
temperatures.
2 - Move joystick (4) up/down to highlight the required function, then
press OK (4).
Selecting the colour palette
Function is only available if the infrared image type has been selected.
1 - Move joystick (4) up/down to toggle between the colour palettes.
Selecting image type (infrared image, real image) (testo 868, 871 and 872)
1 - Select image type function. To do this, see Getting to know the
menu.

The image type switches automatically from infrared image to real
image and vice versa.
Setting the scale
Function is only available if the infrared image type has been selected.
Automatic scaling continuously adjusts the scale to the relevant
measuring values and the colour assigned to a measuring value
changes.
With manual scaling, fixed limit values are defined and the colour
assigned to a measuring value is fixed (important for visual image
comparisons).
Scaling influences the way the infrared image is shown on the display
but does not affect the recorded measuring values.
A standardized scale is set via ScaleAssist depending on the inside
and outside temperature.
1 - Select the scale function. To do this, see Getting to know the
menu.
All manuals and user guides at all-guides.com
2 - Move joystick (4) up/down to select auto, manual or ScaleAssist
and then press OK (4).

Automatic scaling is activated. Ais displayed bottom right.
Manual scaling
1 - Move joystick (4) left/right until min. temperature (lower limit
value) is highlighted.
- Move joystick (4) up/down to set the value and then press OK (4).
2 - Move joystick (4) left/right until min. temperature (lower limit
value) and max. temperature (upper limit value) are highlighted.
- Move joystick (4) up/down to set the values and then press OK
(4).
3 - Move joystick (4) left/right until max. temperature (upper limit
value) is highlighted.
- Move joystick (4) up/down to set the value and then press OK (4).

Manual scaling is activated. Mis displayed bottom right.
Configuring the quick select key
- The quick select key (5) is an additional navigation option, which
you can use to call up functions simply by pressing a key.
1 - Move joystick (4) right to select the configure key function.
2 - Move joystick (4) up/down to highlight the required function, then
press OK (4).

The icon for the selected function is displayed bottom right.
3 - Press (5) to call up the function.
All manuals and user guides at all-guides.com
all-guides.com
0970 8721 en 01
All manuals and user guides at all-guides.com

Other manuals for 865

1

This manual suits for next models

3

Other TESTO Laboratory Equipment manuals

TESTO 868 User manual

TESTO

TESTO 868 User manual

TESTO 875i Reference guide

TESTO

TESTO 875i Reference guide

TESTO 880 Reference guide

TESTO

TESTO 880 Reference guide

TESTO 875i Reference guide

TESTO

TESTO 875i Reference guide

TESTO 875i-1 User manual

TESTO

TESTO 875i-1 User manual

TESTO 875-KIT User manual

TESTO

TESTO 875-KIT User manual

TESTO 868 User manual

TESTO

TESTO 868 User manual

TESTO 882 Reference guide

TESTO

TESTO 882 Reference guide

TESTO 881 Reference guide

TESTO

TESTO 881 Reference guide

TESTO 876 User manual

TESTO

TESTO 876 User manual

TESTO 882 User manual

TESTO

TESTO 882 User manual

TESTO 885 User manual

TESTO

TESTO 885 User manual

TESTO 883 User manual

TESTO

TESTO 883 User manual

TESTO 865s User manual

TESTO

TESTO 865s User manual

TESTO 880 User manual

TESTO

TESTO 880 User manual

TESTO 622 User manual

TESTO

TESTO 622 User manual

TESTO 872s User manual

TESTO

TESTO 872s User manual

TESTO 868s User manual

TESTO

TESTO 868s User manual

TESTO 871s User manual

TESTO

TESTO 871s User manual

TESTO Saveris 0560 1020 User manual

TESTO

TESTO Saveris 0560 1020 User manual

Popular Laboratory Equipment manuals by other brands

CODEX DNA BioXp 3250 user guide

CODEX DNA

CODEX DNA BioXp 3250 user guide

Endress+Hauser Analytik Jena Biometra TAdvanced Quick reference guide

Endress+Hauser

Endress+Hauser Analytik Jena Biometra TAdvanced Quick reference guide

Munro TRITON-2 Operation and maintenance manual

Munro

Munro TRITON-2 Operation and maintenance manual

Luxul XPE-2500 Quick install guide

Luxul

Luxul XPE-2500 Quick install guide

Sartorius Vivaspin 500 operating instructions

Sartorius

Sartorius Vivaspin 500 operating instructions

Kinematica POLYTRON PT 1200 E manual

Kinematica

Kinematica POLYTRON PT 1200 E manual

Optika Italy B-190 Series instruction manual

Optika Italy

Optika Italy B-190 Series instruction manual

Thermo Electron 3911 Operating and maintenance manual

Thermo Electron

Thermo Electron 3911 Operating and maintenance manual

Omron CJ1-CT021 Operation manual

Omron

Omron CJ1-CT021 Operation manual

Du Pont SORVALL RT6000B operating instructions

Du Pont

Du Pont SORVALL RT6000B operating instructions

NACALAI TESQUE COSMOSIL HPLC quick start guide

NACALAI TESQUE

NACALAI TESQUE COSMOSIL HPLC quick start guide

Biosan Sunflower Mini-Shaker 3D Service manual

Biosan

Biosan Sunflower Mini-Shaker 3D Service manual

GYROZEN 1580 Service manual

GYROZEN

GYROZEN 1580 Service manual

Kulzer Palamat Premium Series Operating	 instruction

Kulzer

Kulzer Palamat Premium Series Operating instruction

Selecta MACROTRONIC BLT instruction manual

Selecta

Selecta MACROTRONIC BLT instruction manual

PureAiro GUARDIAN 155 Installation & operation manual

PureAiro

PureAiro GUARDIAN 155 Installation & operation manual

Hygiena EnSURE Touch manual

Hygiena

Hygiena EnSURE Touch manual

N-BIOTEK NB-101M operating manual

N-BIOTEK

N-BIOTEK NB-101M operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.