TESTO 300 NEXT LEVEL Manual

testo 300 NEXT LEVEL - flue gas analyzer
Short instructions

Register your Testo product at www.testo.com/register and receive a one-year
free warranty extension.
The product registration is valid for 30 days after purchase.
For product registration terms and conditions and participating countries, please
go to www.testo.com/register

Contents
Contents
1About this document ...........................................................................3
2Safety and disposal..............................................................................3
3Product-specific safety instructions ..................................................3
4Use.........................................................................................................4
5Product description .............................................................................5
5.1 Front view...............................................................................................5
5.2 Rear view ...............................................................................................6
5.3 Connections ...........................................................................................7
6Commissioning ....................................................................................8
6.1 Mains unit / energy storage unit .............................................................8
6.1.1 Charging the energy storage unit ...........................................................8
6.2 Switching instrument on and off .............................................................9
6.3 Display - user interface.........................................................................10
7Using the product...............................................................................12
7.1 Overview of main menu ( ).............................................................12
7.2 Overview of measurement types ( ).............................................14
7.3 Overview of options ( ) .................................................................15
7.4 Overview of protocols ( ) ...............................................................16
7.5 Get the measurement data in 3 steps ..................................................17
7.6 Connecting Smart Probes and testo Smart App...................................18
7.6.1 Attaching the testo Bluetooth®Connector (0554 3004)........................18
7.6.2 Smart Probes compatible with the instrument ......................................19
7.6.3 Establishing a connection with the testo Smart App.............................19
7.7 Clean the measuring instrument ..........................................................19
8Technical data ....................................................................................21
8.1 Product-specific approvals ...................................................................23
9Contact and support ..........................................................................23


1 About this document
3
1About this document
•The instruction manual is an integral part of the instrument.
•Keep this documentation to hand so that you can refer to it when necessary.
•Please read this instruction manual through carefully and familiarize yourself
with the product before putting it to use.
•Hand this instruction manual on to any subsequent users of the product.
•Pay particular attention to the safety instructions and warning advice in order
to prevent injury and damage to the product.
2Safety and disposal
Please observe the Testo information document (enclosed with the product).
3Product-specific safety instructions
CAUTION
The condensate may be acidic.
Risk of burns to the hands!
-
Wear acid-resistant safety gloves, glasses and overalls to empty the
condensate.
•Make sure that the condensate has been fully emptied out of the condensate
trap before the measuring instrument is stored for a long time.
•Before disposing of the product, the condensate trap must be emptied and
the condensate in the crude gas tube disposed of in a suitable container.
•When testing a gas pipe, pay attention to the following:
WARNING
Dangerous mixture of gases
Danger of explosion!
-
Make sure there are no leaks between the sampling point and the measuring
instrument.
-
Do not smoke or use naked flames during the measurement.

4Use
4
4Use
The testo 300 NEXT LEVEL is a measuring instrument which enables the
professional flue gas analysis of combustion systems, such as
•small combustion plants (oil, gas, wood, coal)
•low-temperature and condensing boilers
•gas heaters.
Using the instrument, these systems can be adjusted and checked for
compliance with the applicable limit values.
The instrument has been verified as a short-term measuring instrument and
should not be used as a safety (alarm) device. It is intended for indoor use only.
The following tasks can also be carried out using the instrument:
•Regulating the O2, CO and CO2, NO, NOxvalues in combustion plants to
ensure optimum operation.
•Draught measurement.
•4Pa measurement.
•Measuring and regulating the gas flow pressure in gas heaters.
•Measuring and optimising the flow and return temperatures of heating
systems.
•Measuring the CO concentration in the ambient air.
•The instrument can be used for measurements on CHP plants in accordance
with the first German Federal Immission Control Ordinance (BImSchV).
•In principle, the CO sensor can also be used for measurements on CHP
plants. If you carry out more than 50 measurements on CHP plants per year,
please contact your nearest Testo service centre or send the instrument to
Testo Service for checking.
An NOxfilter for the CO sensor can be ordered as a spare part to replace a used
filter.

5 Product description
5
5Product description
5.1 Front view
1
USB interface/
mains connection
4
User interface
2
Gas outlet
5
Condensate container
3
On/Off button
6
Connections

5Product description
6
5.2 Rear view
1
Attachment point for carrying
strap
2
Magnets
Explanation of icons
IMPORTANT
Magnetic field
Damage to other devices!
-Keep a safe distance away from products that could be
damaged by the effects of magnetism (e.g. monitors,
computers or credit cards).
At the end of its useful life, deliver the product to the separate
collection point for electric and electronic devices (observe local
regulations) or return the product to Testo for disposal.
testo 300 NEXT LEVEL complies with the Korean safety
standard.
testo 300 NEXT LEVEL is Bluetooth-enabled

5 Product description
7
China RoHS
5.3 Connections
1
Probe connections for additional
probes and testo Bluetooth®
Connector
3
Flue gas socket
2
Integrated ambient air probe
4
Differential pressure
measurement connection
There must be no more than one extension lead (0554 1201)
connected between flue gas socket and flue gas probe.

6Commissioning
8
6Commissioning
6.1 Mains unit / energy storage unit
The measuring instrument is supplied with an energy storage unit.
Fully charge the energy storage unit before using the measuring
instrument.
If the measuring instrument is completely discharged, charge it for at
least 30 minutes before turning the meter on and using it again.
If the mains unit is connected, the measuring instrument is
automatically powered via the mains unit.
Only charge the energy storage unit at an ambient temperature of 0 to
35°C.
6.1.1 Charging the energy storage unit
1
Connect the instrument plug of the mains unit to the mains unit socket
on the measuring instrument.
2
Plug the mains plug of the mains unit into a mains socket.
The charging process will start. LED in the condensate trap will flash.
The charging process will stop automatically when the energy storage
unit is fully charged.
If the energy storage unit is fully drained, the charging time at room
temperature is approx. 5-6 hours. LED in the condensate trap lights up
continuously in red.

6 Commissioning
9
6.2 Switching instrument on and off
Current
status
Action Function
Instrument
off
Press the button for
a long time (> 3 s)
Instrument is switched on.
When the measuring instrument is started for the first time, the setup
wizard guides you through the following setting parameters step by
step:
- Country version
- Language
- Wireless LAN
- Date and time
- Own company address
- E-mail account
A tutorial can be started after the setup wizard.
The tutorial demonstrates the general operation and the most
important functions of the measuring instrument using examples.
Instrument
on
Press the button
briefly (< 1 s)
Instrument is switched to standby mode.
The instrument is re-activated when the
button is pressed again.
Instrument
on
Press the button for
a long time (> 1 s)
Selection: [OK] Instrument is switched
off or cancel the instrument being
switched off with [Cancel].
Unsaved readings are lost when the measuring instrument is switched
off.

6Commissioning
10
6.3 Display - user interface
1
Measurement types
2
Status bar
3
Menu
4
Open the
Fuels
selection list
5
Select Customer/measuring site
6
Select reading display type
7
Protocols
8
Start measurement
Pause measurement
Stop measurement
9
Options
Further symbols on the user interface (without numbering)
Repeat measurement
One level back
One level back
One level back
Cancel process
Print values

6 Commissioning
11
Save report
Save and send report

7Using the product
12
7Using the product
7.1 Overview of main menu ( )
Main menu Description
Customer / Measuring site
Create, edit and delete customer and system
information.
Protocols
Call up, delete and send measurements that
have been performed (various formats
possible).
Saved reports
Call up and delete measurement report.
Gas path check
For perfect operation of the measuring
instrument, regular tightness testing of
measurement systems (measuring
instrument + flue gas probe) is
recommended.
Device Settings
Settings
- Country version and language
- WiFi
- Date & Time
- Own company address
- Bluetooth
- Sensor protection
- NO
₂
addition
- O2 ref.
- Height compensation
- Alarm limits
- Display brightness
- Hotspot

7 Using the product
13
Main menu Description
Sensor Diagnosis
Overview of the sensors fitted and their
condition.
Error List
Call up error reports
Device information
Information
- Device name
- Serial number
- MIN
- Last service
- Free memory
- Operating hours
- Operating hours since last service
- Software version
- Firmware version
- Firmware date
- qA version
- qA date
Server information
Information about the available server
E-mail
Set up an e-mail account and the e-mail
account can be called up.
To set up the e-mail account on the
testo 300 NEXT LEVEL, the IMAP
setting must be activated in the e-mail
account at your account provider. You
can find more information in your e-mail
account itself, e.g. under FAQs or
Settings.
My Apps
Additional applications
- Alarm clock
- Gallery
- Browser
- Calendar
- Pocket calculator
- QuickSupport
- File manager
Help
Aids
- Device registration
- Tutorial
- Setup wizard
- Online help
- Testo website
- Send error report
- Update via USB

7Using the product
14
7.2 Overview of measurement types ( )
Measurement types
Flue gas
Draught
BImSchV
CO undiluted
Smoke No.
Differential pressure
Differential temp.
O2Air
Gas flow
Oil flow
CO ambient
Tightness test 1
Tightness test 2
Let by test
4 Pa measurement

7 Using the product
15
7.3 Overview of options ( )
Options
Description
Config. measurem. view
Add, delete ( ) measurement parameters,
change measurement views ( ) and units
(click on (Unit).
Zeroing Gas Sensors
Manual sensor zeroing.
Menu is only available for measurements
with gas sensors.

7Using the product
16
7.4 Overview of protocols ( )
Protocols
Feature
Print values
Print out measuring values via Bluetooth®.
Save
Save measuring values, including selected
customers / measuring sites. Saved measuring
values can be retrieved in the main menu.
Finish protocol
Create, save and send measurement report,
including
- Own company data
- Format and print
- Customer data
- Comments and pictures
- Select measurements
- Signature
Saved reports can be retrieved in the main menu.

7 Using the product
17
7.5 Get the measurement data in 3 steps
1
Switch instrument on:
Press button > 1 s.
2
Connect probe and place in flue gas
pipe.
3
Start measurement and read off
measuring values.
You will also find further information about your testo 300 flue gas
analyzer in the online instruction manual on the Testo website,
www.testo,com, under the product-specific download.

7Using the product
18
7.6 Connecting Smart Probes and testo
Smart App
The testo 300 NEXT LEVEL has the option of establishing a Bluetooth®
connection with wireless probes via the testo Bluetooth®Connector as well as a
connection to the testo Smart App at the same time.
If the testo 300 NEXT LEVEL is used with Smart Probes, they must be
at least 20 cm apart.
7.6.1 Attaching the testo Bluetooth®Connector
(0554 3004)
Once the testo Bluetooth®Connector is plugged in, all the warning and
safety instructions for the testo 300 NEXT LEVEL apply.
WARNING
Danger of suffocation!
The testo Bluetooth
®Connector is a small part that can be swallowed.
Keep out of reach of children.
1
Connect the testo Bluetooth®
Connector to the TUC 1 or TUC 2
socket on the testo 300 NEXT
LEVEL.
Once the connection has been successfully established, a testo
Bluetooth®Connector icon appears on the testo 300 NEXT LEVEL
status display.
You can now connect up to 4 Smart Probes in parallel with the testo
300 NEXT LEVEL.
Table of contents
Other TESTO Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

DH Instruments
DH Instruments E-DWT-H instruction sheet

az-instrument
az-instrument 8918 instruction manual

Profoscope
Profoscope Proceq operating instructions

Hanna Instruments
Hanna Instruments HI 2400 instruction manual

Lighthouse Worldwide Solutions
Lighthouse Worldwide Solutions ApexZ Operator's manual

Entes
Entes EVM-05C quick start guide

ELECTROMATIC
ELECTROMATIC Check-line DT-205LR operating manual

Endress+Hauser
Endress+Hauser Memograph M Brief operating instructions

Nippon
Nippon MA-3000 RD-5+SC-5 instruction manual

KROHNE
KROHNE TIDALFLUX IFM 4110 PF Installation and operating instructions

Atlanta
Atlanta BYK m200 manual

KROHNE
KROHNE VFM 1091 I Installation and operating instructions