Install the High-Speed Data Converter (HSDC) Pro Software
9
SBAU323A–January 2019–Revised January 2019
Submit Documentation Feedback Copyright © 2019, Texas Instruments Incorporated
Setup Procedure
2.1 Install the High-Speed Data Converter (HSDC) Pro Software
Download the most recent version of the HSDC Pro software from www.ti.com/tool/dataconverterpro-sw.
Follow the installation instructions to install the software.
2.2 Install the TSW12D1620EVM-CVAL GUI Software
1. Download the TSW12D1620EVM-CVAL graphical user interface (GUI) software from the EVM tool
folder at www.ti.com/tool/TSW12D1620EVM-CVAL.
2. Extract the files from the compressed zip file.
3. Run the executable file (setup.exe), and follow the instructions.
2.3 Connect the EVM and TSW14DL3200EVM via the FMC-TSW14DL3200EVM Adapter Card
With the power off, connect the TSW12D1620EVM-CVAL to the TSW14DL3200EVM through the FMC-
TSW14DL3200EVM adapter card as illustrated in Figure 2-1. Make sure that the standoffs provide the
proper height for robust connector connections.
2.4 Connect the Power Supplies to the Boards (Power Off)
1. Confirm that the power switch on the TSW14DL3200EVM is in the off position. Connect the power
cable to a 12-V DC (minimum 3 A) power supply. Verify the proper supply polarity by confirming that
the outer surface of the barrel connector is GND and the inner portion of the connector is 12 V.
Connect the power cable to the EVM power connector.
2. Confirm that the power switch on the TSW12D1620EVM-CVAL is on the off position. Connect the
power cable to a 5-V DC (minimum 3 A) power supply for the TSW12D1620EVM-CVAL. If using an
adjustable or lab DC power supply, adjust the voltage setting to 5.3 V. Verify the proper supply
polarity by confirming that the outer surface of the barrel connector is GND and the inner portion of the
connector is a positive voltage. Connect the power cable to the EVM power connector.
CAUTION
Make sure that the power connections to the EVMs are the correct polarity.
Failure to do so can result in immediate damage.
Make sure that the 12-V power supply is connected to the TSW14DL3200EVM
and not the TSW12D1620EVM-CVAL. Providing the TSW12D1620EVM-CVAL
with 12 V of power can result in immediate damage.
Leave the TSW12D1620EVM-CVAL and TSW14DL3200EVM power switches
in the off position until directed later.
2.5 Connect the Clock Signal Generator to the EVM (RF Output Disabled Until Further
Directed)
Connect a signal generator to the DEVCLK input of the EVM through a band-pass filter. This signal
generator must be a low-noise signal generator. In addition, TI recommends a Trilithic-tunable band-pass
filter to minimize harmonics and noise coming from the generator. Configure the signal generator for the
desired clock frequency in the range of 0.2 GHz to 1.6 GHz. For best performance when using an RF
signal generator, the power input to the CLK SMA connector must be 9 dBm (2.2 VPP into 50 Ω). The
signal generator must increase above 9 dB by an amount equal to any additional attenuation in the clock
signal path, such as the insertion loss of the band-pass filter and cables. For example, if the filter insertion
loss is 2 dB, the signal generator must be set to 9 dBm + 2 dB = 11 dBm.