Safety Summary
The following general safety precautions must be observed during all phases of operation,
service and repair of this equipment. Failure to comply with these precautions or with
specific warnings elsewhere in this manual violates safety standards of design,
manufacture and intended use of the equipment. Thrane & Thrane A/S assumes no
liability for the customers failure to comply with these requirements.
GROUND THE EQUIPMENT
To minimise shock hazard, the equipment chassis and cabinet must be connected to an
electrical ground and the cable instuctions must be followed.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the equipment in the presence of flammable gases or fumes. Operation of
any electrical equipment in such an environment constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Operating personnel must not remove equipment covers. Component replacement and
internal adjustment must be made by qualified maintenance personnel. Do not replace
components with the power cable connected. Under certain conditions, dangerous
voltages may exist even with the power cable removed. To avoid injuries, always
disconnect power and discharge circuits before touching them.
DO NOT SERVICE OR ADJUST ALONE
Do not attempt internal service or adjustments unless another person, capable of
rendering first aid resuscitation, is present.
DO NOT SUBSTITUTE PARTS OR MODIFY EQUIPMENT
Because of the danger of introducing additional hazards, do not substitute parts or
perform any unauthorized modification to the equipment.
COMPASS SAFE DISTANCE
Minimum safety distance of 50 cm from the TT-3606E Message Terminal

This page is intentionally left blank

Table of Contents
Table of Contents
1 Installation...........................................................................................1-1
1.1 Quick system connect and checkout .....................................1-2
1.2 Initial inspection......................................................................1-3
1.3 Storage...................................................................................1-4
1.4 Repacking for shipment .........................................................1-5
1.5 Cabling...................................................................................1-6
1.6 Mounting.................................................................................1-7
2 Description..........................................................................................2-1
2.1 Specifications.........................................................................2-2
2.2 Connectors.............................................................................2-3
2.2.1 Keyboard connector.......................................................2-3
2.2.2 Power connector............................................................2-4
2.2.3 Parallel printer port.........................................................2-5
2.2.4 Serial ports.....................................................................2-6
3 Service................................................................................................3-1
3.1 Disassembling........................................................................3-1
3.2 Configuration..........................................................................3-3
4 Technical description..........................................................................4-1
4.1 Detailed specification.............................................................4-1
4.2 Special I/O..............................................................................4-3
5 Mechanical outlines............................................................................5-1
5.1 TT-3606E ...............................................................................5-1
5.2 Flush mount............................................................................5-3
5.3 Mounting bracket....................................................................5-4
19Mar07 Page i

Table of Contents
This page is intentionally left blank
Page ii 19Mar07

Quick system connect and checkout Installation
1 Installation
This chapter provides specific information about installation of the
TT-3606E Message Terminal and information about initial
inspection, storage and repacking for shipment.
Figure 1 TT-3606E Message Terminal
19Mar07 Page 1-1

Installation Quick system connect and checkout
1.1 Quick system connect and checkout
The following brief outline may be used to get the TT-3606E
Message terminal up and running
•Unpack system components
•Connect the keyboard to the TT-3606E
•Connect a DC power source to the TT-3606E
The TT-3606E should then start the actual application program.
Please refer the manual for the specific application program.
Page 1-2 19Mar07

Initial inspection Installation
1.2 Initial inspection
WARNING
To avoid hazardous electrical shock, do not perform electrical
tests if there is any sign of shipping damage to any portion of the
front or rear panel or the outer cover. Read the safety summary
at the front of this manual before installing or operating the
3606E Message Terminal.
Inspect the shipping carton immediately upon receipt for evidence of
mishandling during the transit. If the shipping carton is severely
damaged or water stained, request that the carrier's agent be
present when opening the carton. Save the carton packing material
for future use.
Contents of the shipment should be as listed in the enclosed packing
list. If the contents are incomplete, if there is mechanical damage or
defect, or if the 3606E Message Terminal does not work properly,
notify your dealer.
After you unpack the 3606E Message Terminal, inspect it thoroughly
for hidden damage and loose components or fittings.
Inspect the cable harness for stress, loose or broken wires, or
broken cable tires.
Examine all the components for loose or missing hardware.
Tighten all loose hardware.
19Mar07 Page 1-3

Installation Storage
1.3 Storage
The 3606E may be stored or shipped in temperatures within the
limits -40° C to +80° C. It is advisable to protect 3606E from extreme
temperature variation which can cause excessive condensation. It is
recommended that the 3606E is unpacked immediately on delivery.
Page 1-4 19Mar07

Repacking for shipment Installation
1.4 Repacking for shipment
The shipping carton for the 3606E has been carefully designed to
protect the Message Terminal and its accessories during shipment.
This carton and its associated packing material should be used
when repacking for shipment. Attach a tag indicating the type of
service required, return address, model number and full serial
number. Mark the carton FRAGILE to ensure careful handling.
If the original shipping carton is not available, the following general
instructions should be used for repacking with commercially
available material.
1. Wrap the 3606E in heavy paper or plastic. Attach a tag indicating
the type of service required, return address, model number and
full serial number.
2. Use a strong shipping container, e.g. a double walled carton of
160 kg test material.
3. Protect the front- and rear panel with cardboard and insert a 7
cm to 10 cm layer of shock absorbing material between all
surfaces of the equipment and the sides of the container.
4. Seal the shipping container securely.
5. Mark the shipping container FRAGILE to ensure careful
handling.
19Mar07 Page 1-5

Installation Cabling
1.5 Cabling
For any installation it is required that all attached cables are shielded
and equipped with shielded connectors, which are properly
connected to the shield of the cable. Furthermore every shield
should have a low impedance connection to an electrical ground.
Before using the TT-3606E Message Terminal for the first time
check out that all cables are correctly wired and fastened.
Please notice that the DC-input range applies to the DC voltage
measured at the pin's on the power connector on the 3606E. This
means that the power cable characteristic should be taken into
account. The cable should allow the DC, measured at the input pin's
on the 3606E power connector, to stay within limits even though it
has to carry a current of 3 A.
Please notice, that the wires must be properly connected in the
connector and all pin’s for each power input must be connected to
the respective wire.
A cable using 2 mm2 (AWG 14) wire's of length 4 m fulfils the
requirements.
Please notice, that the cable connections must be properly installed.
Page 1-6 19Mar07

Mounting Installation
1.6 Mounting
The TT-3606E Message Terminal may be mounted in several ways.
If the mounting bracket is not used, the TT-3606E Message
Terminal may be flush mounted in a consol by using the 4 screw
holes on the rear.
The mounting bracket may be used either to mount the TT-3606E
Message Terminal on a horizontal surface or a vertical surface. In
both cases the angle can be adjusted in steps of 7.5°. This is done
by loosening the hand wheels slightly and then move the upper part
of the TT-3606E Message Terminal into the wanted angle. Please
remember to tighten the handwheels again.
When assembling the mounting bracket together with the TT-3606E
Message Terminal it is important that the small indications on the
cylinders are in-line with the indications on the rear of TT-3606E
Message Terminal.
When installing the TT-3606E on a vertical surface it is necessary to
mount the mounting bracket opposite the way it is mounted for
horizontal installation.
Please refer to the chapter describing the detailed mechanical
outlines of the TT-3606E Message Terminal and mounting bracket.
19Mar07 Page 1-7

Installation Mounting
This page is intentionally left blank
Page 1-8 19Mar07

Mounting Description
2 Description
This chapter describes the TT-3606E Message Terminal. This
encompasses specifications as well as provides specific information
about the available features and interfaces.
19Mar07 Page 2-1

Description Specifications
2.1 Specifications
Processor 386SX-40MHz
RAM 2 MB
Flash DISK 2 MB
Display 10.4” Color TFT flatpanel, 640x480
Floppy drive 3.5”
Keyboard i/f 5-pin mini-DIN
Parallel printer port 25 pin SubD female connector
Serial port COM1 9 pin SubD male connector, DTE type
Serial port COM2 9 pin SubD male connector, DTE type
Environmental Meets or exceeds all INMARSAT
specifications for the Inmarsat-C Network for
SOLAS with distress call functions. (CN114
and IEC 945 requirements). Meets CE-
marking requirements. Wheelmark approved.
Power Source 10 to 32 V floating DC, 15 pin SubD female
Power Consumption App. 20 Watts, maximum
App. 13 Watts, typical
Fuse Internal automatic recovering poly fuse
Ambient Temperature -20°C to 55°C operating
-40°C to 80°C storage.
Compass safe distance 50 cm
(measured in accordance with the standards
specified in ISO/R 694, Method B)
Dimensions H x W x D 221x 297 x 114.5 mm w/o bracket
256 x 297 x 114.5 mm w bracket at vertical
position
Weight 3.1 kg (including mounting bracket)
Table 1 TT-3606E Message Terminal
Page 2-2 19Mar07

Connectors Description
2.2 Connectors
This section describes the functions and pin assignments of
connectors found on the rear of the TT-3606E. Figure 2 shows the
connector part of the TT-3606E Message Terminal.
Figure 2 Rear connectors
2.2.1 Keyboard connector
The figure below indicates the pin assignment of the keyboard
connector as seen from the rear of the TT-3606E Message
Terminal.
N/C hgClock
+5V f
eGround
N/C dcData
Figure 3 Keyboard connector
19Mar07 Page 2-3

Description Connectors
2.2.2 Power connector
The power input connector is a standard 15 pin SubD male
connector, located on the rear panel of the TT-3606E and the pin
assignments are as indicated below. The Remote ON/OFF input
makes it possible to place an eventual on/off switch at any location.
Pin Name Signal Description
1,2,9,10 + supply 10-32 VDC (Battery Positive input)
4,5,12,13 - supply DC Return (Battery Negative input)
6 Remote ON/OFF ON if connected to “- supply”
OFF if floating
7,8 SGND Chassis (Secondary GND)
Ground GND Shield
3,11,14,15 NC
Table 2 Power connector
Page 2-4 19Mar07
Table of contents
Other Thrane&Thrane Touch Terminal manuals

Thrane&Thrane
Thrane&Thrane Sailor 250 FleetBroadband User manual

Thrane&Thrane
Thrane&Thrane Explorer 300 User manual

Thrane&Thrane
Thrane&Thrane BGAN Thrane&Thrane Explorer 700 User manual

Thrane&Thrane
Thrane&Thrane EXPLORER 122 User manual

Thrane&Thrane
Thrane&Thrane Explorer 727 User manual

Thrane&Thrane
Thrane&Thrane TT-3000LRIT mini-C User manual

Thrane&Thrane
Thrane&Thrane TT-6007A User manual

Thrane&Thrane
Thrane&Thrane TT-3710A EXPLORER 500 User manual

Thrane&Thrane
Thrane&Thrane EXPLORER 500 User manual

Thrane&Thrane
Thrane&Thrane Explorer 300 User manual