10.Sound and Light indication
Press keypad - - - Di
Enter into programming mode Bright - -
Exit from the programming
mode
Bright - - Di
Alarm Bright - - Alarm
11. Detailed Programming Guide
To enter the programming mode
* Master code #
999999 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code # New code #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3 0 # Entry is by card only
3 1 # Entry is by card and PIN together
3 2 # Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
11.1 User Settings
To add a Pin user 1 User ID number # PIN #
The ID number is any number between 1 & 2000. The
PIN is any four digits between 0000 & 9999 with the
exception of 1234 which is reserved. Users can be added
continuously without exiting programming mode as
follows:
1 User ID no 1 # PIN # User ID no 2 # PIN #
To delete a PIN user 2 User ID number #
Users can be deleted continuously without exiting
programming mode
To change the PIN of a PIN user
(This step must be done out of
programming mode)
* ID number # Old PIN # New PIN # New PIN #
To add a card user (Method 1)
This is the fastest way to enter cards,
user ID number auto generation.
1 Read card #
Cards can be added continuously without exiting
programming mode
To add a card user (Method 2)
This is the alternative way to enter cards
using User ID Allocation. In this method a
User ID is allocated to a card. Only one
user ID can be allocated to a single card.
1 ID number # Read card #
User can be added continuously without exiting
programming mode
To add a card user (Method 3)
Card number is the last 8 digits printed
on the back of the card,
user ID number
1 Card number #
User can be added continuously without exiting
programming mode
To add a card user (Method 4)
In this method a User ID is allocated to a
card number. Only one user ID can be
allocated to the card number
1 ID number. # Card number. #
User can be added continuously without exiting
programming mode
To delete a card user by card. Note users
can be deleted continuously without
exiting programming mode
2 Read Card #
To delete a card user by user ID. This
option can be used when a user has lost
their card
2 User ID #
To delete a card user by card number.
This option can be used when the user
want to make the change but the card
has lost
2 Card number #
Note users can be deleted continuously without
exiting programming mode
To add a card and PIN user in card and PIN mode (3 1 # )
To Add a card and Pin user
(The PIN is any four digits between 0000
& 9999 with the exception of 1234 which
is reserved.)
Add the card as for a card user
Press *to exit from the programming mode
Then allocate the card a PIN as follows:
* Read card 1234 # PIN # PIN #
To change a PIN in card and PIN mode
(Method 1) Note that this is done outside
programming mode so the user can
undertake this themselves
* Read Card Old PIN # New PIN # New PIN #
To change a PIN in card and PIN mode
(Method 2) Note that this is done outside
programming mode so the user can
undertake this themselves
* ID number # Old PIN # New PIN # New PIN #
To delete a Card and PIN user just delete
the card
2 User ID #
To add a card user in card mode (3 0 # )
To Add and Delete a card user The operating is the same as adding and deleting a card
user in 3 2 #
To delete All users
To delete ALL users. Note that this is a
dangerous option so use with care
2 0000 #
To unlock the door
For a PIN user Enter the PIN then press #
For a card User Read card
For a card and PIN user Read card then enter PIN #
11.2 Door Settings
Relay Output Delay Time
To set door relay strike time * Master code # 4 0~99 # *
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside
buzzer will beep automatically to remind people to close the door and continue for 1 minute before
switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and
alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the
default being 1 minute.
To disable door open detection. (Factory
default)
6 0 #
To enable door open detection 6 1 #
Alarm output time
To set the alarm output time (0-3 minutes)
Factory default is 1 minute
5 0~3 #
Keypad Lockout & Alarm Output options.If there are 10 invalid cards or 10 incorrect PIN numbers
in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside
buzzer will operate for 10 minutes, depending on the option selected below.
Normal status: No keypad lockout or
alarm (factory default)
7 0 # (Factory default setting)
Keypad Lockout 7 1 #
Alarm and inside buzzer operate 7 2 #
To remove the alarm
To reset the Door Forced Open warning Read valid card or Master Code #
To reset the Door Open Too Long warning Close the door or Read valid card or Master Code #