TIS IO-8G User manual

TIS IO 8-GANG PUSH-BUTTON PANEL
INSTALLATION MANUAL
With its elegant shape and design, the IO 8G
is available in black or white with 8 stylish push
buttons. It includes a backlit white LED that can
be customized with an engraving of any icon for
friendly use.
Automation Made Easy
Model: IO-8G
PRODUCT INFORMATION
BARCODE (UPC-A)
6 58921 80008 9
PRODUCT SPECIFICATIONS
Input Using Panel Addition 2-3 Digital Input
Output
Using Panel Addition 3R 3 Relay Output 3A/5A
Using Panel Addition 3DL-12V 12V DC 50mA Output
Using Panel Addition 2DL-IRE IR Emitter
TIS Bus``
Number of devices on 1 line Max. 64
Bus voltage 12-32 V DC
Current consumption <45 mA / 24 V DC
Protection Reverse Polarity Protection
ESD Protection
Operating and display
elements
push buttons 8 push buttons with White/Orange LED
Backlight White backlit indicators
TIS bus TIS Protocol messages and commands
Dimensions Width × Length × Height 90mm (94mm peak) × 13mm × 129mm
Housing
Materials PC fire proof / acrylic in front
Casing color Silver plating frame, acrylic white or black
Internal Parts color Black & White
IP rating IP 50

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
2
Data Cable
Use screened stranded RS485 data cable
with four twisted pairs. Congure devices in
a “Daisy Chain.”
Do not cut or terminate live data cables.
Electrical Wires
The recommended wire size for light
channels is 1.5mm - 2.5mm for loads, if you
are using the Panel Addition 3R type. The
installer should consider the total current
consumption when selecting the wires.
Warranty
There is a two-year warranty provided
by law. The hologram warranty seal and
product serial number are available on
each device.
Read Instructions
We recommend that you read this
Instruction Manual before installation.
Safety instructions
Electrical equipment should only be
installed and tted by electrically skilled
persons.
Failure to follow the instructions may cause
damage to the device and other hazards.
These instructions are an integral part of
the product and must remain with the end
customer.
Programming
This device can be tested and programmed
manually. Advanced programming
requires knowledge of the TIS Device
Search software and instruction in the TIS
advanced training courses.
Simple Installation
You can use 2 screws to install this panel
on wall; it ts on most junction box sizes.
Mounting Location
Install in a dry, indoor area with a suitable
temperature and humidity range.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
3
Insert a large athead screwdriver in
the hole of the Panel Cover. Rotate the
screwdriver 90 degrees.
1
INSTALLATION STEPS
2Separate the Cover, Main Panel, and
Wall Base from each other.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
4
Remove the 2 screws on the Panel Addi-
tion cover.
3
INSTALLATION STEPS
4
Smart Home
Smart Home
Connect the Wall Base and Panel Addi-
tion in this position. Place the upper pins
as shown, and then push the down pins
down with your ngers to assemble.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
5
It should look like this following the cor-
rect assembly.
INSTALLATION STEPS
5
6
Turn off the main electrical source before
installation.
Connect the Cat5e TIS BUS wire to the
Panel Addition.
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
PANEL ADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
IO-8G
To the TIS BUS Network
Cat5e
WARNING! HIGH VOLTAGE

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
6
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
TIS IR Receiver probe
To the TIS BUS Network
Cat5e
IO-8G
INSTALLATION STEPS
7Connect the other connection if needed as per the panel addition type.
FOR PANEL ADDITION 2DL-IRR
You can connect 2 digital inputs to any
switch or window magnet.
You can add an External Infrared Receiv-
er to the IRR Port, connect as follows:
▸
the IR Receiver black wire to GND
▸
Gray wire to REC
▸
Red wire to VCC Terminal.
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5econnection
low voltage cable
low voltage cable
Traditional Switch
L
S2
S1
S1
L
L
S2

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
7
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
Cat5e connection
+24V(brown-orange)
D+(blue-green)
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Emitter
Model : ADD-2DL-IRE
TIS BUS Input : 45mA/24V DC
IR- IR+ GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
TIS IR Emitter probe
To the TIS BUS Network
Cat5e
IO-8G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Emitter
Model : ADD-2DL-IRE
TIS BUS Input : 45mA/24V DC
IR- IR+ GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
Door Magnet Contact
To the TIS BUS Network
Cat5e
IO-8G
INSTALLATION STEPS
FOR PANEL ADDITION 2DL-IRE
You can connect 2 digital inputs to any
switch or window magnet.
▸
Connect the IR Emitter Probe’s positive
wire to IR+ terminal.
▸
Connect the negative wire to IR-terminal.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
8
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
low voltage cable
3rd party sensor
PANEL ADDITION
3 Digital Input with 12V Output
Model : ADD-3DL-12V
TIS BUS Input : 45mA/24V DC
+12V GND Z3 Z2 Z1
www.tissmarthome.com
Output: DC 12V/50mA
D- +24V
GND D+
C5
C2
PULSE
1&2
2&3
NONE
1P
2P
3P
RELAY
1&2
2&3
NO
NC
1 2 3
RELAY
1&2
2&3
NO
NC
1 2 3
TAMPERALARM12V GND
CON1
1 2 3
LED1
818-6B V2.3
2016-11-09
To the TIS BUS Network
Cat5e
IO-8G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
PANEL ADDITION
3 Digital Input with 12V Output
Model : ADD-3DL-12V
TIS BUS Input : 45mA/24V DC
+12V GND Z3 Z2 Z1
www.tissmarthome.com
Output: DC 12V/50mA
D- +24V
GND D+
Door Magnet Contact
To the TIS BUS Network
Cat5e
IO-8G
INSTALLATION STEPS
FOR PANEL ADDITION 3DL-12V
You can connect 3 digital inputs to any
switch or window magnet.
Also, you can connect any 12V operated
smoke detector or any 3rd party sensor
with NC/NO connection to the 12V GND
and Z1-Z3 terminals as per the diagram.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
9
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
24+V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5
mm Electric Cable
Open
Close
220 ~ 110 Volt
Connect To N
Connect To L
O-OFF
I-ON
MCB
PANEL ADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
to the TIS BUS Network
Cat5e
IO-8G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5 mm Electric Cable
PANEL ADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
Connect To L
O-OFF
I-ON
MCB
Connect To N
IO-8G
To the TIS BUS Network
Cat5e
INSTALLATION STEPS
LIGHTING CONNECTION
▸
Connect the live wire to COM
▸
Connect the loads wire to Out1-Out3
to terminals
▸
Connect load neutral wire to main
neutral in the distributor box.
SHUTTER / CURTAIN CONNECTION
▸
Connect the Supply wire to COM
▸
Connect the Open wire to OUT1
▸
Connect the Close wire to OUT2
▸
Shutter neutral connection, if it exists,
can be looped to main neutral in the
distributor box.
FOR PANEL ADDITION 3R-5A
WARNING: Set the curtain function in the
software before connecting the wires.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
10
1.5 mm Electric Cable
2.5 mm Electric Cable
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
COOL
HEAT
FAN
COM
PANELADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
24+V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5
mm Electric Cable
PANELADDITION
3Output Relay 5 Amp
Model: ADD3-R5-A
TISBUS Input : 75-45mA/24V DC
OutputCurrent : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- 24+V
GND D+
Connect To L
O-OFF
I-ON
MCB
LOW
MEDIUM
HIGH
To the TIS BUS Network
Cat5e
IO-8G
INSTALLATION STEPS
FCU CONNECTION
▸
Connect the supply wire to com
▸
Connect the FAN Low, Medium, and
High wires to Out1, Out2, and Out3 in
the same order.
HVAC CONNECTION
▸
Connect the HVAC COM (supply)
wire to COM
▸
Connect the Cool, Heat, and FAN
wires to Out1, Out2, and Out3 in the
same order.
FOR PANEL ADDITION 3R-5A
WARNING: Set the FCU function in the
software before connecting the wires.
WARNING: Set the HVAC function in the
software before connecting the wires.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
11
1.5 mm Electric Cable
1.5 mm Electric Cable
O-OFF
I-ON
MCB
Connect To L
Connect To N
TIS AIR BUS Convertor
Model NO : TIS-AIR-BUS-3W
AC Input : 100~240 V AC
www.tissmarthome.com
TIS AIR
TIS BUS Output : 100mA/12 V DC
D- +24V
GND D+
N L
INSTALLATION STEPS
Mount the device on the wall using 2
screws on the junction box.
8
FOR PANEL ADDITION AIR-BUS-3W
▸
Connect the live wire to the L terminal,
▸
Connect the neutral wire to N termi-
nal.

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
12
INSTALLATION STEPS
Connect the main Luna panel vertically
to the part installed on the wall; install the
upper part by making sure the buckles
are completely inside.
10
Using your ngers, pull the protective
plastic cover vertically, remove it, and
throw it away.
9

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
13
INSTALLATION STEPS
Push on the bottom part of the main pan-
el to x it to the wall and complete the
assembly.
Turn on the power source. The panel
should turn ON.
11
12

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
14
PAIRING (MANUAL PROGRAMMING)
LIGHTS / SHUTTERS PROGRAMMING
You can pair the light channels with any wall panel. To do so, follow these steps:
RCU80-UT8-IN WARNING! HIGH VOLTAGE!
TIS-BUS
GND D- D+ 24+V
PRG
1 2 3 4 5 678
1 2 3 4 5 678
-+
8
7
GND
6
54
32
10-0V
DIGITAL INPUT
GND
1
1Press any button on any relay or dimmer
module channel for 6 seconds so that the
LED indicator light of that button starts
blinking.
6”
On the IO Push buttons, shortly press on
any push button or press the wall switch
that is connected to the dry inputs of the
panel addition zones.
2
Test the button on the panel by short
pressing it for ON/OFF and long pressing
it to dim (if channel is dimmable).
3

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
15
USER OPERATION
LIGHTS / SHUTTERS / SCENE CONTROL
You can use the 8 push buttons to control lights and other devices.
Press on the push buttons as follows:
Short press for lights ON/OFF, shutter
open/close, or to run a scene.
Long press to dim or ramp up the lights.
Double click to trigger a special pro-
grammed scene.
×2

INSTALLATION MANUAL
MODEL: IO-8G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
8-GANG PUSH-BUTTON PANEL
16
TROUBLESHOOTING
The panel’s buttons
blinks rapidly
Reason: The panel address conicts with another
device in the TIS network. You need to press and hold
any push button for 6 seconds so that the panel can
get a new address.
The panel buttons’
LEDs do not turn ON,
and the device is not
powered
Reason 1: There is no TIS-BUS power or no connec-
tion to the L/N input (if used AIR bus-3W converter).
Reason 2: The TIS 24V power supply is not connect-
ed to the TIS-BUS.
The wall panels fail to
pair with other devices
Reason 1: The TIS-BUS connection has a problem, or
the wire has a short.
Reason 2: The manual programming function is dis-
abled on the device (it is enabled by default).
The wall panels fail
to control the device
channels
Reason 1: The TIS-BUS connection has a problem, or
the wire has a short.
Reason 2: The programming address is faulty.
The backlite display
on some buttons is the
wrong color if the light
is turned ON/OFF
Reason: Software LED backlite setting has been
changed. Please program it to show the correct color.
Table of contents
Other TIS Control Panel manuals
Popular Control Panel manuals by other brands

Klimosz
Klimosz HoGas duo instruction manual

Tyco Fire Protection Products
Tyco Fire Protection Products AutoPulse Z-20 installation manual

Monicon
Monicon GTR-100B user manual

Danfoss
Danfoss ECL Comfort 210 installation guide

nilan
nilan Compact S Series Installation instruction

HeatLink
HeatLink HEP025RT Installation, operation and maintenance manual