Titon auramode TP524 User manual

ventilation systems
auramode TP524
EN Product Manual HRV controller
NL Producthandleiding HRV-regelaar
FR Manuel produit Commande HRV
DE Produkthandbuch HRV-Steuergerät

2
NL
Waarschuwingen, veiligheidsinformatie en richtlijnen. . . . 12
Productbeschrijving. . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Inhoud verpakking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Afmetingen en installatie van het display . . . . . . . . . . . . . .13
Bevestigingsmiddel. . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Bedrading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Inschakelen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Bedieningsorganen en bediening van de auramode. . . . . . 14
Bedrijfsmodi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Boost uitschakeling . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Pictogrammen voor snelheidsinstelling . . . . . . . . . . .15
Plannerconguratie. . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Luchtvochtigheid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Boost Overrun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Schakelaars. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
In bedrijf stellen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Menu- & submenu-items SETUP. . . . . . . . . . . . . . . . . . . . . . .18
Onderhoud. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Buitenzijde reinigen . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Standaardinstellingen auramode. . . . . . . . . . . . . . . . . . . . . .19
Waarschuwingsmeldingen . . . . . . . . . . . . . . . . . . . . . . . . . . .20
EN
Warnings, Safety Information and Guidance . . . . . . . . . . . . . 4
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Packaging Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Dimensions & Display Installation . . . . . . . . . . . . . . . . . . . . . . 5
Fixing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Powering Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
auramode Controls & Operation . . . . . . . . . . . . . . . . . . . . . . . . 6
Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Boost Inhibit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Speed Setting Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Scheduler Conguration . . . . . . . . . . . . . . . . . . . . . . . . . 7
Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Boost Overrun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Commission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SETUP Menu & Sub-menu Items. . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning Exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
auramode Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Warnings messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3
FR
Avertissements, consignes de sécurité et directives. . . . . . . 21
Description du produit. . . . . . . . . . . . . . . . . . . . . . . . . .22
Contenu de l'emballage . . . . . . . . . . . . . . . . . . . . . . . .22
Dimensions et installation de l'achage . . . . . . . . . . . . . . .22
Fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Câblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Mise sous tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Commande et fonctionnement de auramode. . . . . . . . . . . .23
Modes de fonctionnement . . . . . . . . . . . . . . . . . . . . . . 23
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Interdiction de ventilation forcée. . . . . . . . . . . . . . . . .24
Icônes réglage de vitesse . . . . . . . . . . . . . . . . . . . . . . .24
Conguration du programmateur . . . . . . . . . . . . . . . .25
Humidité. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Filtre. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Temporisateur de sécurité de vitesse forcée . . . . . . .25
Commutateurs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Mise en service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Réinitialiser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Menu SETUP et options de sous-menu . . . . . . . . . . . . . . . . .27
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Nettoyage extérieur. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Réglages par défaut du auramode. . . . . . . . . . . . . . . . . . . . . 28
Messages d'avertissement. . . . . . . . . . . . . . . . . . . . . . . . . . . .29
DE
Warnungen, Sicherheitsinformationen und
Orientierungshilfen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Produktbeschreibung . . . . . . . . . . . . . . . . . . . . . . . . . .31
Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Abmessungen und Display-Installation . . . . . . . . . . . . . . . .31
Befestigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Verdrahtung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Einschaltung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Bedienelemente und Betrieb von auramode . . . . . . . . . . . . 32
Betriebsmodi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
EINRICHTUNG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Turbosperre. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Symbole für die Drehzahleinstellung . . . . . . . . . . . . . 33
Konguration des Steuerprogramms . . . . . . . . . . . . .34
Feuchtigkeit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Turboübersteuerung . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Schalter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Inbetriebnahme. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Zurücksetzen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
SETUP-Menü und Untermenüelemente. . . . . . . . . . . . . . . . . 36
Wartung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Äußere Reinigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
auramode-Voreinstellungen. . . . . . . . . . . . . . . . . . . . . . . . . .38
Warnmeldungen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

EN
Warnings, Safety Information and Guidance
Important Information Read instructions fully before the installing this appliance.
1. This manual covers the operation of the HRV control system only, it
must therefore be read in conjunction with the relevant heat recovery
unit Product Manual.
2. Installation of the appliance and accessories must be carried out by a
qualied and suitable competent person and be carried out in clean,
dry conditions where dust and humidity are at minimal levels.
3. All wiring must conform to current I.E.E. Wiring Regulations and all
applicable standards and Building Regulations.
4. auramode must be connected using the communication cable provid-
ed.
5. Control & communication cables should not be placed within 50mm
or on the same metal cable tray as any 230V lighting or power cables.
6. Ensure all cable glands are fully tightened.
7. The unit must be stored in a clean and dry environment. Do not install
the appliance in areas where the following may be present or occur;
• Excessive oil or a grease laden atmosphere,
• Corrosive or ammable gases, liquids or vapours,
• Ambient temperatures above 40°C or below -5°C,
• Humidity levels above 90% or is a wet environment.
8. The appliance is not suitable for installation to the exterior of the
dwelling.
9. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervi-
sion or instruction concerning use of the appliance in a safe way and
understand the hazards involved.
10. Children should be supervised to ensure that they do not play with
the appliance.
11. To ensure compliance with the requirements Building Regulations
Approved document Part F use of the default schedule is not recom-
mended. The schedule should be cleared in the Scheduler section of
the menu.
4

Product Description
The auramode is a programmable timer & 3-4 speed switch for commissioning compatible Titon
HRV units. The auramode is connected to the HRV via a wired connection.
Packaging Contents
Inspect the unit when taking delivery. Check the unit for damage and that all accessories have
been supplied Package supplied with:-
1 x auramode controller.
1 x 14m auramode communication cable.
1 x Product Manual.
Any shortages or damage must be immediately reported to the supplier.
Dimensions & Display Installation
The auramode should be mounted in position convenient for the householder.
Fixing
Open auramode case using a small, at bladed screwdriver in the rectanguler openings on the
right-hand side. Fix backplate - the auramode can be xed over a standard surface mount or
recessed pattress; connect the communication cable and clip front of auramode to the backplate.
86.00
86.00
16.70
35.80
00:00 XXX
2016:05:03 XXXX
123
Time Auto / Manual/Status
Date & Day
5

Wiring
Communication cable connection to the auramode is by a pre tted plug on the supplied cable.
Connection to the HRV unit is to screw terminals on the HRV PCB.
Powering Up
The auramode is powered by the communication cable from the HRV unit. On powering up the
HRV the controller starts in AUTO mode and displays INITIALIZING.. while waiting for the
HRV unit to complete its start-up procedures.
auramode Controls & Operation
auramode has 4 buttons to control these are used to control and setup auramode. Each button
has multiple functions detained below.
Modes of Operation
The auramode has three modes of operation:
1. AUTO Speed in controlled by the programmed schedule (default mode).
2. MANUAL Speed is set manually, either by cycling through the speeds with the
QUICK BUTTON or by using to increase and to decrease speed.
3. SETUP Used to change settings.
Black/White12V
Yellow
Green
Orange
0V
A
B
HRV
Connection to HRVConnection to auramode
Enter Setup Menu [Long Press]
Select Menu Item
Fix Setting
Switch to Auto Mode
Increase Fan Speed
Navigate Menus
Change Settings
QUICK BUTTON
Cycle Fan Speeds
Toggle Manual / Auto Mode
Clear Filter Messages
Decrease Speed
Navigate Menus
Change Settings
6

In MANUAL mode press or press and hold [2 seconds] the QUICK BUTTON to enter AUTO
mode.
In AUTO mode press either , or QUICK BUTTON to change to MANUAL mode.
Press and hold [5 seconds] the to enter SETUP mode.
In MANUAL or AUTO mode press and hold [5 seconds] the QUICK BUTTON to reset any lter
warning message.
SETUP
To Enter SETUP by press and hold [5 seconds] the button.
Follow the on screen prompts and menu structure detailed in the SETUP Menu & Submenu Items
section and modify and congure the auramode to your requirements.
Boost Inhibit
Boost Inhibit is an additional option in the Schedule menu when selecting the speed the unit will
run at. During the Boost Inhibit period the unit remains in either Speed 1 or Speed 2 and does not
respond to external Boost switches or the Humidity sensor.
Speed Setting Icons
Listed below are the various icons are used to represent the speeds:-
Speed 1 or
Speed 2 or
Speed 3 or
Speed 4 or
Speed 1 with boost inhibit
Speed 2 with boost inhibit
Scheduler Conguration
The scheduler changes the speed setting at specic times. Times and speed settings are user
programmed in either seven day, weekday & weekend or individual day groups.
1. Select single day or day group to edit.
2. Press .
3. Select event to edit hh:mm - event not set yet.
4. Press .
5. Set hour.
6. Press .
7. Set minutes.
8. Press .
9. Set speed.
10. Press .
11. Select next event to edit, SAVE or EXIT.
It is possible to erase single event while setting its time
to hh:mm.
Events can be entered in random sequence: they are sorted automatically after saving.
►EXIT 1-5
►SAVE
01 00:00
02 06:30
03 08:30
04 12:00
05 13:30
1 to 5 Weekday screen
7

Humidity
The HRV has a relative humidity (RH) sensor. The humidity menu species at what RH the HRV will
boost to speed 3.
Filter
The HRV’s lters require regular replacement depending on environmental conditions. The
replacement period is set in the Filter section during setup as are the checked and replaced dates.
In normal use lter check and replace messages will appear on the main screen after changing or
checking lters messages are cleared by pressing and holding [5 seconds] the QUICK BUTTON.
Boost Overrun
auramode has separate timers for wet room and kitchen boost that controls the time the HRV
remains at speed 3 after all switches have been released.
Switches
The HRV has multiple switch inputs whose function can be programmed. SW1, 2 & 3 are volt free
switch inputs and LS1 & 2 are live switch inputs.
Switch Options
Kitchen Boost Wet Room Boost SummerBOOST Disable Speed 1 Setback Speed 4
Kitchen Wet Room SummerBoost
Commission
The Commission menu screen is used to program the
supply and extract fan speeds. When the menu screen is
selected the HRV fans will start to run at speed 2.
Use & to move between fan speeds the cursor
underlines the supply or extract speed %. Pressing the
highlights the speed % selected to be modied and the
HRV immediately switches to run supply and extract at
the corresponding speeds. Use the & to modify the
speed % and to save. When all the required fan speeds
have been congured navigate to the SAVE option to save &
exit the Commission menu to the SETUP menu, the unit will return to AUTO operation.
Use and to move between fan speeds - the cursor will highlight the supply or extract
speed. Press to select the required speed - the HRV will begin running at the selected speed,
and modify the speed using and . When speed is correct press and either select
another speed or if all the required fan speeds have been set as required navigate to the SAVE
option to save all settings to memory and return to the SETUP menu.
Reset
Reset menu sets to the default values.
►SAVE Commission
SUPPLY EXTRACT
18.0% 18.0%
40.0% 40.0%
70.0% 70.0%
100.0% 100.0%
Commissioning screen
8

SETUP Menu & Sub-menu Items
Menu item Description
EXIT Exit SETUP menu
Display Menu for display settings
EXIT
Backlight Change LCD Backlight brightness
Contrast Change LCD contrast
Language Menu to change language
EXIT
English
Nederlands
Français
Deutsch
Polski
Español
Italiano
Lietuvių
Русский
Українська
Slovenski
Magyar
3 Speed 1 to 3 Speed - 1 to 4 Speed toggle
Defaults Set display back-light and contrast to default values
Clock Menu to change date and time
EXIT
Time Set time 24 hour clock only
Date Set date and day
Scheduler Menu to congure timer controlled speeds.
EXIT
Clear all Clear all scheduled events - HRV will default to Speed 2
Edit
EXIT
1-7 Set same events for all days of the week. (day group)
1-5 Set same events for working days (Monday to Friday).
6-7 Set same events for weekend (Saturday & Sunday).
1..7 Set events for selected day.
EXIT Exit without saving
Save Save events and exit
1,2,..7, 8 Set time and position (speed level) of the event
Default Set Scheduler to default values
Humidity Set value of humidity threshold
Filter Menu to change lter settings
EXIT
Repl.Period(m.) Set lter replace warning time, 1 to 24 months.
Checked yy.mm.dd Set last checked date.
Replaced yy.mm.dd Set last replaced date.
Boost Overrun Menu for setting Kitchen & Wet Room overrun timers
Switches Menu to set switch functions & SummerBOOST®
Commission Menu to Set speeds 1 to 3 or 1 to 4 & SummerBOOST on/o
Save
Reset Reset auramode unit
9

Maintenance
The auramode is maintenance free.
Cleaning Exterior
For best results use a clean damp cloth. Do not use abrasive cleaners, solvents or any other uids.
auramode Default Settings
Scheduler
Days 1 to 5 Mon, Tue, Wed, Thur & Fri Days 6 & 7 Sat & Sun
Position Time Speed Position Time Speed
01 00:00 Speed 1 01 00:00 Speed 1
02 06:30 Speed 2 02 07:30 Speed 2
03 08:30 Speed 1 03 09:30 Speed 1
04 12:00 Speed 2 04 12:00 Speed 2
05 13:30 Speed 1 05 14:00 Speed 1
06 18:00 Speed 2 06 18:00 Speed 2
07 22:30 Speed 1 07 23:30 Speed 1
08 00:00 Speed 1 08 00:00 Speed 1
To ensure compliance with the requirements Building Regulations Approved document Part F use
of the default schedule is not recommended. The schedule should be cleared in the Scheduler
section of the menu.
Filter Display Switches
Replace Period 6 months Language English SW1 Speed 3 Kitchen
Contrast 36 SW2 Speed 3 Wet Room
Checked Date Current set date Backlight 192 SW3 SummerBOOST
3 / 4 Speed Toggle 3 Speed LS1 Speed 3 Kitchen
Replaced Date Current set date LS2 Speed 3 Wet Room
SummerBOOST ON
Speeds
Speed Supply Extract
1 18.0% 18.0%
2 40.0% 40.0%
3 70.0% 70.0%
4 100.0% 100.0%
10

Warnings messages
Clock Realtime clock errors - Reset Clock Time.
Time Filter check time errors in settings - Check lter settings.
Replace. Filter Replace lter.
Check Filter 2/3s of lter replace time has elapsed.
Connection Controller has lost connection with the HRV.
Press OK to exit
11

NL
Waarschuwingen, veiligheidsinformatie en richtlijnen
Belangrijke informatie Lees deze gebruiksaanwijzing helemaal door alvorens dit apparaat te
installeren.
1. Deze handleiding beschrijft alleen de bediening van het HRV
regelsysteem en moet om deze reden samen met de betreende
handleiding voor het apparaat voor het terugwinnen van warmte
gelezen worden.
2. De installatie van het apparaat en toebehoren dient door bevoegd
en competent personeel uitgevoerd te worden en in een schone en
droge omgeving met zo min mogelijk stof en vochtigheid.
3. Alle bedradingen moeten aan de huidige I.E.E.
Bedradingsvoorschriften voldoen en alle toepasselijke normen en
Bouwvoorschriften.
4. De auramode moet met de meeleverde communicatiekabel worden
aangesloten.
5. De regel & communicatiekabels mogen niet binnen 50mm of op
dezelfde metalen tray als 230V verlichtings- of stroomkabels geplaatst
worden.
6. Zorg ervoor dat alle kabelwartels goed zijn aangedraaid.
7. De unit moet in een schone en droge omgeving opgeslagen worden.
Het apparaat mag niet in ruimten geïnstalleerd worden met;
• Veel olie of een vettige omgeving,
• Corrosieve of ontvlambare gassen, vloeistoen of dampen,
• Omgevingstemperaturen hoger dan 40°C of lager dan -5°C,
• Een vochtigheidsgraad hoger dan 90% of een natte omgeving.
8. Dit apparaat mag niet aan de buitenkant van een woning
geïnstalleerd worden.
9. Dit apparaat mag door kinderen van 8 jaar en ouder gebruikt worden
en personen met fysieke, zintuiglijke of geestelijke beperkingen of
met een gebrek aan ervaring of kennis zolang deze personen onder
toezicht staan of instructies hebben ontvangen omtrent het veilige
gebruik van het apparaat en zich bewust zijn van de eventuele
gevaren.
10. Houd toezicht op jonge kinderen om te voorkomen dat zij met het
apparaat spelen.
12

Productbeschrijving
De auramode is een programmeerbare timer en schakelaar met 3-4 snelheden voor het in
bedrijf stellen van compatibele HRV-eenheden van Titon. De auramode wordt via een bedrade
verbinding op de HRV aangesloten.
Inhoud verpakking
Inspecteer bij ontvangst de unit. Controleer de eenheid op schade en controleer of alle accessoires
zijn meegeleverd. Inhoud van de verpakking:-
1 x auramode-regelaar.
1 x 14m communicatiekabel voor auramode.
1 x Producthandleiding.
Ontbrekende onderdelen of schade moet onmiddellijk aan de leverancier gemeld worden.
Afmetingen en installatie van het display
86.00
86.00
16.70
35.80
00:00 XXX
2016:05:03 XXXX
123
Tijd Auto/Manual/Status
Datum en dag
De auramode dient op een voor de bewoner gemakkelijk bereikbare plaats te worden
gemonteerd.
Bevestigingsmiddel
Open de behuizing van de auramode door een kleine, platte schroevendraaier in de rechthoekige
openingen aan de rechterkant te steken. Monteer de achterplaat - de auramode kan over een
standaard opbouwdoos of inbouwdoos worden gemonteerd; sluit de communicatiekabel aan en
klem het front van de auramode op de achterplaat.
13

Bedrading
De aansluiting van de communicatiekabel op de auramode wordt tot stand gebracht via een
voorgemonteerde stekker op de meegeleverde kabel. De aansluiting op de HRV-eenheid wordt
tot stand gebracht via schroefaansluitingen op de printplaat van de HRV.
Inschakelen
De auramode wordt van stroom voorzien via de communicatiekabel van de HRV-eenheid.
Na inschakeling van de HRV start de regelaar op in de AUTO modus en verschijnt de melding
INITIALIZING.. (BEZIG MET INITIALISEREN) waarbij gewacht wordt tot de HRV-
eenheid de opstartprocedures ervan voltooid heeft.
Bedieningsorganen en bediening van de auramode
De auramode heeft 4 knoppen voor het bedienen en instellen van de auramode. Iedere knop
heeft meerdere functies zoals hieronder beschreven.
Zwart/Wit12V
Geel
Groen
Oranje
0V
A
B
HRV
Aansluiting op de HRVAansluiting op de auramode
Naar menu Setup gaan [lang
drukken]
Menu-item selecteren
Instelling vastleggen
Op Auto modus overschakelen
Ventilatorsnelheid verhogen
Door menu's navigeren
Instellingen wijzigen
SNELKNOP
Ventilatorsnelheden doorlopen
Wisselen tussen Manual en Auto modus
Filtermeldingen wissen
Snelheid verlagen
Door menu's navigeren
Instellingen wijzigen
14

Bedrijfsmodi
De auramode heeft drie bedrijfsmodi:
1. AUTOM De snelheid wordt geregeld via het geprogrammeerde schema
(standaardmodus).
2. MANUAL De snelheid wordt met de hand ingesteld, ofwel door met de SNELKNOP de
snelheden te doorlopen ofwel door de snelheid met te verhogen en met
te verlagen.
3. SETUP Hiermee worden instellingen gewijzigd.
Druk in de MANUAL modus op of houd de SNELKNOP [2 seconden] ingedrukt om in de
AUTO modus te komen.
Druk in de AUTO modus op of , of de SNELKNOP om om te schakelen naar de
MANUAL modus.
Houd [5 seconden] ingedrukt om in de SETUP modus te komen.
Houd in de MANUAL of AUTO modus de SNELKNOP [5 seconden] ingedrukt om een
mogelijke lterwaarschuwingsmelding terug te stellen.
SETUP
U komt in SETUP (INSTELLINGEN) door de knop [5 seconden] ingedrukt te houden.
Volg de instructies op het scherm en de in de sectie Menu- & submenu-items SETUP beschreven
menustructuur en wijzig en congureer de auramode naar wens.
Boost uitschakeling
Boostblokkering is een extra optie in het menu Schedule (Planner) bij het selecteren van de
snelheid waarop de eenheid zal draaien. Tijdens de boostblokkeringstijd blijft de eenheid in of
Snelheid 1 of Snelheid 2 en reageert die niet op externe boostschakelaars of de vochtsensor.
Pictogrammen voor snelheidsinstelling
Hieronder zijn de pictogrammen voor de verschillende snelheden weergegeven:-
Snelheid 1 of
Snelheid 2 of
Snelheid 3 of
Snelheid 4 of
Snelheid 1 met boostblokkering
Snelheid 2 met boostblokkering
15

Plannerconguratie
Met de planner kan de snelheidsinstelling op specieke tijdstippen worden gewijzigd. Tijdstippen
en snelheidsinstellingen kunnen door de gebruiker worden geprogrammeerd in groepen van
zeven dagen, werkdagen & weekeindes of afzonderlijke dagen.
1. Selecteer enkele dag of daggroep om te bewerken.
2. Druk .
3. Selecteer de gebeurtenis om te bewerkenhh:mm - gebeurtenis nog niet ingesteld.
4. Druk .
5. Stel het uur in.
6. Druk .
7. Stel de minuten in.
8. Druk .
9. Stel de snelheid in.
10. Druk .
11. Selecteer de volgende gebeurtenis om te bewerken,
SAVE (OPSLAAN) of EXIT (AFSLUITEN).
Het is mogelijk één enkele gebeurtenis te wissen
terwijl het tijdstip ervan op hh:mm wordt ingesteld.
Gebeurtenissen kunnen in willekeurige volgorde ingevoerd worden: ze worden na het
opslaan automatisch gesorteerd.
Luchtvochtigheid
De HRV heeft een sensor die de relatieve vochtigheid (RV) meet. In het menu Vochtigheid wordt
gespeciceerd bij wat voor RV de HRV naar Snelheid 3 verhoogd zal worden.
Filter
De lters van de HRV dienen regelmatig vervangen te worden afhankelijk van de
omgevingsomstandigheden. De vervangingstermijn wordt ingesteld in de sectie Filters tijdens
het instellen, evenals de datums voor controle en vervanging. Bij normaal gebruik worden er
ltercontrole- en vervangingsmeldingen op het hoofdscherm weergegeven. Na vervanging of
controle van de lters worden de meldingen gewist door de SNELKNOP [5 seconden] ingedrukt te
houden.
Boost Overrun
De auramode heeft afzonderlijke timers voor het boosten van de natte ruimte en de keuken
waarmee de tijdsduur wordt geregeld dat de HRV op snelheid 3 blijft nadat alle schakelaars zijn
vrijgezet.
►AFSL 1-5
►OPSL
01 00:00
02 06:30
03 08:30
04 12:00
05 13:30
Scherm 1 t/m 5 werkdagen
16

►OPSL Instellen
TOEVOER AFVOER
18,0% 18,0%
40,0% 40,0%
70,0% 70,0%
100,0% 100,0%
Schakelaars
De HRV heeft meerdere schakelaaringangen waarvan de functie geprogrammeerd kan worden.
SW1, 2 & 3 zijn spanningsvrije schakelaaringangen en LS1 & 2 zijn faseschakelaaringangen.
Schakelopties
Keuken-boost Natteruimte-boost SummerBOOST
uitschakelen
Setback Snelheid 1 Snelheid 4
Keuken Badkamer SummerBoost
In bedrijf stellen
In het menuscherm Commission (Inbedrijfstelling)
worden de snelheden van de toevoer- en afvoerventilator
geprogrammeerd. Wanneer het menuscherm wordt
geselecteerd, zullen de HRV-ventilatoren op Snelheid 2
gaan lopen.
Navigeer met en tussen ventilatorsnelheden;
de cursor onderstreept het percentage van de toevoer-
of afvoersnelheid. Door op te drukken wordt
het te wijzigen snelheidspercentage gemarkeerd
en geselecteerd en schakelt de HRV onmiddellijk
over op toevoer- en afvoerbedrijf op de bijbehorende snelheden. Gebruik en om
het snelheidspercentage te wijzigen en om het op te slaan. Ga zodra alle gewenste
ventilatorsnelheden zijn gecongureerd, naar de optie SAVE (OPSLAAN) om op te slaan,
verlaat het menu Commission (Inbedrijfstelling) en ga naar het menu SETUP; de eenheid keert
vervolgens terug naar AUTO (AUTOMATISCH) bedrijf.
Navigeer met en tussen ventilatorsnelheden - de cursor markeert de toevoer- of
afvoersnelheid. Druk op om de gewenste snelheid te selecteren - de HRV zal dan op de
geselecteerde snelheid gaan lopen, en wijzig de snelheid met en . Druk wanneer de
snelheid goed is op en selecteer nog een snelheid of ga, als alle gewenste ventilatorsnelheden
naar behoefte zijn ingesteld, naar de optie SAVE (OPSLAAN) om alle instellingen in het geheugen
op te slaan en naar het menu SETUP terug te keren.
Reset
Met het menu Reset (Opnieuw instellen) worden de standaardwaarden ingesteld.
Scherm Inbedrijfstelling
17

Menu- & submenu-items SETUP
Menu item Beschrijving
AFSLUITEN Menu SETUP verlaten
Display Menu voor weergave-instellingen
AFSL
Achtergrondverlichting Helderheid LCD-achtergrondverlichting wijzigen
Contrast Contrast LCD-scherm wijzigen
Taal Menu om de taal te wijzigen
AFSL
English
Nederlands
Français
Deutsch
Polski
Español
Italiano
Lietuvių
Русский
Українська
Slovenski
Magyar
Snelheid 3 Wisselen 1-3 snelheden - 1-4 snelheden
Standaard instll. Achtergrondverlichting en contrast van scherm op
standaardwaarden instellen
Klok Menu om de datum en tijd te wijzigen
AFSL
Tijd Alleen tijd 24-uurs klok instellen
Datum De datum en dag instellen
Planner Menu om timergestuurde snelheden te congureren.
AFSL
Alles wissen Alle geplande gebeurtenissen wissen - de HRV zal zich
standaard op Snelheid 2 instellen
Bewerken
AFSL
1-7 Zelfde gebeurtenissen instellen voor alle dagen van de week.
(daggroep)
1-5 Zelfde gebeurtenissen instellen voor werkdagen
(maandag t/m vrijdag).
6-7 Zelfde gebeurtenissen instellen voor weekeinde
(zaterdag en zondag).
1..7 Gebeurtenissen instellen voor geselecteerde dag.
AFSL Afsluiten zonder op te slaan
OPSL Gebeurtenissen opslaan en afsluiten
1,2,..7, 8 Tijd en stand (snelheidsniveau) van de gebeurtenis instellen
Standaardinstll Planner op standaardwaarden instellen
Luchtvochtigheid Waarde van vochtigheidsdrempel instellen
Filter Menu om lterinstellingen te wijzigen
AFSL
Per.Vervang.(m) Tijd waarschuwing voor lter vervangen instellen,
1 tot 24 maanden.
18

Gecontroleerd jj.mm.dd
Datum laatste controle instellen.
Vervangen jj.mm.dd Datum laatste vervanging instellen.
Boost beheerder Menu voor instellen van overschrijdingstimers
Keuken & Natte ruimte
Schakelaars Menu om schakelaarfuncties en SummerBOOST®
Instellen Menu om snelheden 1-3 of 1-4 & SummerBOOST aan/uit
OPSL
Reset auramode-eenheid terugstellen
Onderhoud
De auramode is onderhoudsvrij.
Buitenzijde reinigen
Gebruik voor de beste resultaten altijd een schone en vochtige doek. Gebruik geen schurende
reinigingsmiddelen, oplosmiddelen of andere vloeistoen.
Standaardinstellingen auramode
Planner
Dagen 1 t/m 5 ma, di, wo, do & vr Dagen 6 & 7 za & zo
Stand Tijd Snelheid Stand Tijd Snelheid
01 00:00 Snelheid 1 01 00:00 Snelheid 1
02 06:30 Snelheid 2 02 07:30 Snelheid 2
03 08:30 Snelheid 1 03 09:30 Snelheid 1
04 12:00 Snelheid 2 04 12:00 Snelheid 2
05 13:30 Snelheid 1 05 14:00 Snelheid 1
06 18:00 Snelheid 2 06 18:00 Snelheid 2
07 22:30 Snelheid 1 07 23:30 Snelheid 1
08 00:00 Snelheid 1 08 00:00 Snelheid 1
Filter Display Schakelaars
Vervangingstermijn 6 maanden Taal English SW1 Keuken Snelheid 3
Contrast 36 SW2 Natte ruimte Snelheid 3
Datum controle Ingestelde huidige
datum
Achtergrondverlichting 192 SW3 SummerBOOST
Wisselen Snelheid 3 / 4 3 Snelheid LS1 Keuken Snelheid 3
Datum vervanging Ingestelde huidige
datum
LS2 Natte ruimte Snelheid 3
SummerBOOST AAN
19

Snelheden
Snelheid Pulsie Extractie
1 18,0% 18,0%
2 40,0% 40,0%
3 70,0% 70,0%
4 100,0% 100,0%
Waarschuwingsmeldingen
Klok Fouten real-time klok - Kloktijd terugstellen.
Tijd Fouten ltercontroletijd in instellingen - Filterinstellingen controleren.
Filter verv. Filter vervangen.
Filter contr. 2/3e van ltervervangingstijd is verstreken.
Verbinding Verbinding tussen de regelaar en HRV is verbroken.
Klik op OK om af te sluiten
20
Table of contents
Languages:
Other Titon Controllers manuals