Filter Change Alert
The aurastat®V will display an alert
after a specied time when the HRV
lters require changing.
4 x Fan Speeds
The units have 4 programmable
speed settings, all speeds are
variable between 14-100% and allow
independent speed setting of both
supply and extract ventilation rates
1. Setback Speed.
Reduced ventilation.
2. Continuous Speed.
Normal ventilation.
3. Boost Speed.
Increased ventilation
4. SUMMERboost® Speed.
Very high ventilation, only
available during Summer
By Pass operation.
Fan Speed Display
The aurastat®V screen displays the
selected fan speed using the 1-4
stepped icons.
Boost Alert
A programmable timer which displays
a warning message on the aurastat®V
LCD screen after the HRV has been left
in Boost Speed for the specied time.
Summer Mode
Summer Mode operates by slowing or
stopping the supply fan. This reduces
the supply of From Atmosphere air
to the dwelling. Summer Mode is
triggered automatically or via a Volt
Free input. Summer Mode must not be
enabled or installed in dwellings where
open ue combustion appliances are
used.
SUMMERboost®
SUMMERboost® allows both the supply
and extract fans to run at full speed
whenever the Summer Bypass is
activated. By default SUMMERboost®
is enabled. When SUMMERboost®
is triggered by Summer Bypass the
increased fan speed can be prevented
either Manually or Automatically.
Manual - This is by means of a volt-free
switch wired directly into the controller
PCB.
Automatic - This is by means of
a dedicated wall mounted room
thermostat. SUMMERboost® will only
operate when the temperature has
exceeded the thermostat setting.
Should the room temperature fall
below the thermostat setting, then
SUMMERboost® will not operate.
Summer By Pass
Summer Bypass is designed to operate
during hot periods where fresh air can
be vented straight into the property
without being preheated by the
extracted stale air. Summer Bypass
operation is automatically controlled.
The Summer Bypass mechanism diverts
the stale air being extracted from the
dwelling around the heat cell so that
its heat energy is not transferred to
the fresh air being supplied to the
dwelling.
Duct Heater Control
To maintain ventilation ow rates
where prolonged periods of very low
temperatures occur, the facility for the
control of an electrically powered Duct
Heater is provided, MAX 1800W. The
Duct Heater is placed in-line between
the outside supply vent and the From
Atmosphere terminal on the HRV. In
these applications, the heater is used
to pre-warm the outside fresh air
supply before it enters the HRV.
2 x Proportional Sensor
Inputs
Enables connection of environmental
sensors to the HRV which can be used
to proportionally control HRV fan
speeds.
3 x Volt Free Inputs
Enables the connection of single pole
momentary switches, latching switches
or normally open relay contacts
to the HRV. These can be used to
switch between fan speeds or control
SUMMERboost® and Summer Mode.
2 x Live Switch Inputs
These inputs are used to switch the
HRV to Boost Speed via a switched live
input.
Frost Protection Program
During very cold weather, the Frost
Protection Program will detect
temperatures that could cause ice to
form inside the unit. It will reduce
or stop the supply ventilation rate,
thus allowing the warmer stale air to
raise the temperature within the unit
cell to such a level that prevents the
formation of ice. As temperatures
rise the Frost Protection Program
will increase the supply ventilation
ow rate back to the commissioned
settings.
HRV Run Timer
The aurastat®V displays the total run
time of the unit in hours.
Holiday Mode
The aurastat®V can set the HRV to
Holiday Mode. Holiday Mode sets the
HRV to speed 1 Setback Speed, Boost
Inhibit is enabled.
Multiple Internal
Temperature Sensors
The aurastat®V LCD can display the
From Atmosphere and To Atmosphere
air temperatures in real-time.
Additionally the temperature of the
heat cell is monitored.
6