DISC TYPE CHECK VALVES

Introduction
Before beginning installation or maintenance, please read this manual to ensure correct use of
the product. Keep the manual in a safe place for future reference.
Disc type check valves can be used on fluid lines for steam, air, hot and cold water, with
minimum opening differential pressure from 0.001 MPa (0.15 psi) and maximum operating
pressure to 3.0 MPaG (425 psig), and temperatures up to 350 ºC (662 ºF). (Do not use for toxic,
flammable or otherwise hazardous fluids.) Due to their compact design, the check valves can
easily be installed in places where space is limited, and may be installed either horizontally or
vertically. They can be used even with an extremely low pressure differential.
1 MPa = 10.197 kg/cm2, 1 bar = 0.1 MPa
For products with special specifications or with options not included in this manual, contact TLV
for instructions.
The contents of this manual are subject to change without notice.
Continued on next page
Indicates an urgent situation
which poses a threat of death
or serious injury.
Indicates that there is a
potential threat of death or
serious injury.
WARNINGDANGER CAUTION
Indicates that there is a
possibility of injury or equip-
ment/product damage.
1. Safety Considerations
• Read this section carefully before use and be sure to follow the instructions.
• Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
• The precautions listed in this manual are designed to ensure safety and prevent equipment
damage and personal injury. For situations that may occur as a result of erroneous handling,
three different types of cautionary items are used to indicate the degree of urgency and the
scale of potential damage and danger: DANGER, WARNING and CAUTION.
• The three types of cautionary items above are very important for safety; be sure to observe
all of them, as they relate to installation, use, maintenance, and repair. Furthermore, TLV
accepts no responsibility for any accidents or damage occurring as a result of failure to
observe these precautions.
CAUTION
Install properly and DO NOT use this product outside the
recommended operating pressure, temperature and other
specification ranges. Improper use may result in such hazards as
damage to the product or malfunctions that may lead to serious
accidents. Local regulations may restrict the use of this product to
below the conditions quoted.
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the
product has cooled to room temperature. Disassembling or removing
the product when it is hot or under pressure may lead to discharge of
fluids, causing burns, other injuries or damage.
WARNING
DO NOT use for toxic, flammable or otherwise hazardous fluids.
Use only for fluids listed in the specification table. This product is for
intended use only. Improper use may result in such hazards as damage
to the product or malfunctions that may lead to serious accidents.

2. Configuration
CK3M / CK3T / CK3R
Replacement kits available: M = Maintenance parts
R = Repair parts
No.
1
2
3
4
5
6
Name
Body
Inlet Union
Valve Disc
Spring Holder
Coil Spring
Union Gasket
RM
NOTE:
- When requesting a Repair Kit, please specify the minimum opening differential pressure.
- For nominal sizes 15 - 25 mm ( " - 1"), confirm that an identification code of "A" or
later is present on the nameplate as shown in the figure below when requesting replacement
parts. Both Maintenance Kit and Repair Kit will be available for products with such a code.
If no such code is shown on the nameplate, please contact TLV.
- For nominal sizes 32-50 mm (1 " - 2"), both Maintenance Kit and Repair Kit are available
regardless of identification code.
Location of identification code on nameplate
PTFE* Valve Seat
* PTFE = Fluorine Resin
The CK3T inlet union has a PTFE valve seat
insert.
Identification Code
Rubber Sealing
CK3R valve disc is inlaid with rubber.
CAUTION
Be sure to use only the recommended components when repairing
the product, and NEVER attempt to modify the product in any way.
Failure to observe these precautions may result in damage to the
product or burns or other injury due to malfunction or the discharge of
fluids.
Use only under conditions in which no freeze-up will occur.
Freezing may damage the product, leading to fluid discharge, which
may cause burns or other injury.
Do not use excessive force when connecting threaded pipes to the
product. Over-tightening may cause breakage leading to fluid
discharge, which may cause burns or other injury.
Use under conditions in which no water hammer will occur. The
impact of water hammer may damage the product, leading to fluid
discharge, which may cause burns or other injury.
② ⑥ ③ ⑤ ④ ①
2
1
/
4
1
/
2

CK3MG
CKF3M / CKF3R
CKF3MG / CKF3RG
Replacement kits available:
M = Maintenance parts
R = Repair
parts
No.
1
2
3
4
5
6
Name
Body
Inlet Union
Valve Disc
Coil Spring
Union Gasket
Nameplate
RM
NOTE: When requesting a Repair Kit, please specify the minimum opening differential pressure.
Replacement parts are not available for CKF3 series (flangeless) check valves, as special
equipment is required for assembly/disassembly.
Body Fin Rubber Sealing
CKF3R valve disc is inlaid with rubber.
Rubber Sealing
CKF3RG valve disc is inlaid with rubber.
No.
1
2
3
4
5
Body
Valve Disc
Coil Spring
Spring Holder
Nameplate (CKF3M(R)G)
Name
Body Fin
⑥
② ③⑤ ④ ①
②
③
④
①
②
③
⑤④
①
3

3. Specifications
Connectable Flange Standards
*Available only by special order.
Mark Model Sealing Material
Flange Flange Face Finish
Surface roughness: 3.2 - 6.3µmRa (125 - 250 AARH) Serration
Size
mm (in) BS TABLE
A, D, E, F, H, J
F, H, J
A, D, E, F, H, J
PN 6, 10, 16, 25, 40
PN (DIN/EN)
PN 10, 16, 25, 40
ASME/JPI
Class 150, 300
Class 125, 150, 250, 300
15
20
25
32
40
50
65
80
100
( )
( )
(1)
(1 )
(1 )
(2)
(2 )
(3)
(4)
JIS
5, 10, 16, 20, 30K
10, 16, 20, 30K
ASME B16.5 Serration
DIN Serration
CKF3MG
M
−
CKF3M
Metal
F
JIS
ASME
JPI
PN
Fluorine Rubber (FPM) (Standard)
Metal (without "M" mark)
N
CKF3R
CKF3RG
Nitrile Rubber (NBR)*
EEthylene Propylene Rubber (EPDM)*
CKF3M / CKF3R
CKF3MG / CKF3RG
This applies to the flangeless connections; CKF3M, CKF3R, CKF3MG and CKF3RG
Sealing material only
indicated on CKF3RG.
Mark
Mark
4
3
/
2
1
/
4
1
/
2
1
/
2
1
/
4

P*
MPa
[psi]
0.002
(0.02)
[0.3]
0.001
(0.01) [0.15]
0.002
(0.02)
[0.3]
0.001
(0.01)
[0.15]
PMO*
MPaG
[psig]
Appl. Fluids
TMO2)
°C (°F)
CAUTION
* P = Min. Opening Diff. Press.; PMO = Max. Oper. Press.; TMO = Max. Oper. Temp.;
** PTFE = Fluorine Resin,
Perfect sealing cannot be guaranteed for metal or PTFE sealing surfaces.
*** NBR = Nitrile Rubber; FPM = Fluorine Rubber
For rubber sealing surfaces, a closing differential pressure of more than 0.05 MPa
(0.5 bar, 7 psi) will be required for perfect sealing when the valve is closed. (However,
degradation of, or debris on, the rubber sealing surface may prevent perfect sealing.)
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS):
Max. Allowable Pressure. PMA, MPaG (psig):
CK3M, CK3T, CK3R: 1.0 (150) (Brass, Bronze), 2.1 (300) (Stainless Steel);
CKF3M & CKF3R, CKF3MG & CKF3RG: 3.0 (425); CK3MG: 3.2 (450)
Max. Allowable Temperature TMA, °C
(
°F
)
:
CK3M, CK3T, CK3R, CK3MG: 220
(
428
)
; CKF3M & CKF3R, CKF3MG & CKF3RG: 350
(
662
)
1 MPa = 10.197 kg/cm2
15 – 25 ( - 1)
32 – 50 (1 - 2)
15 – 50 ( - 2)
15 – 25 ( - 1)
32 – 50 (1 - 2)
15 – 50 ( - 2)
15 – 25 ( - 1)
32 – 50 (1 - 2)
15 – 50 ( - 2)
CK3M
CK3T
CK3R
CK3MG
Model
Body Mat.Size mm (in)
Sealing Material
Metal**
PTFE**
NBR***
Metal**
15 – 40 ( -1 )
15 – 40 ( -1 )
50 – 100 (2 - 4)
50 (2)
CKF3M
CKF3R
CKF3MG
CKF3RG
Brass
Bronze
St.Steel
Brass
Bronze
St.Steel
Brass
Bronze
St.Steel
St.Steel
1.0 (10) [150]
2.1 (21) [300]
1.0 (10) [150]
1.6 (16) [230]
1.0 (10) [150]
1.6 (16) [230]
2.1 (21) [300]
220
(428)
185
(365)
90
(194)
St.Steel
St.Steel
St.Steel
St.Steel
3.0 (30) [425]
1.6 (16) [230]
3.0 (30) [425]
1.6 (16) [230]
350 (662)
150 (302)
350 (662)
150 (302)
220 (428)
Steam
Air, Water
Steam, Water
Air, Water
Steam, Water
Air, Water
Steam, Water
Metal**
FPM***
Metal**
FPM***
ScrewedFlangeless
25, 40, 50, 80
(1, 1 , 2, 3)
0.002
0.001
0.002
0.001
[2]
[1]
[2]
[1]
(0.3)
(0.15)
(0.3)
(0.15)
0.0015
0.0005
0.0016
0.0005
[1.5]
[0.5]
[1.6]
[0.5]
(0.22)
(0.07)
(0.23)
(0.07)
0.0025
0.0015
0.0024
0.0015
[2.5]
[1.5]
[2.4]
[1.5]
(0.40)
(0.22)
(0.35)
(0.22)
CK3M / CK3T / CK3R
CK3MG
CKF3M / CKF3R
CKF3MG / CKF3RG
Model
Horizontal
MPa [kPa] (psi)
Vertical : Downward
MPa [kPa] (psi)
Vertical : Upward
MPa [kPa] (psi)
Flow Direction
NOTE:
- PMO,TMO may vary according to the options selected. Check nameplate, drawing, etc.
- When the valve has remained closed for a long period of time, the valve and the valve
seat may stick, increasing the necessary minimum opening differential pressure. Make
sure to open the valve properly before the installation.
- In addition, the minimum opening differential pressure varies depending on the direction
of flow due to the influence of the weight of the valve disc. See the table below.
To avoid abnormal operation, accidents or serious injury, install properly and
DO NOT use this product outside of the specification range. Local regulations
may restrict the use of this product to below the conditions quoted.
Minimum Opening Differential Pressure by Direction of Fluid Flow
1 MPa = 10.197 kg/cm2
2
1
/
4
1
/
4
1
/
4
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
+RW:DWHU
6WHDP

Cv Values
Options
* Except nominal size of 40 mm (1 ") for P 0.01 MPa (0.1 bar, 1.5 psi).
**CK3R, CKF3R and CKF3RG (with the rubber sealing) should not be used. Due to the
nature of the rubber, there is a possibility that it may stick to the metal valve seat. So the
CK3R, CKF3R and CKF3RG should not be used as vacuum breakers if they will often
be used with extremely low differential pressures.
Model
Size mm (in)
Cv (US)
Cv (UK)
Kvs (DIN)
Cv (US)
Cv (UK)
Kvs (DIN)
Cv (US)
Cv (UK)
Kvs (DIN)
Cv (US)
Cv (UK)
Kvs (DIN)
Cv (US)
Cv (UK)
Kvs (DIN)
3.7
3.1
3.2
4.6
3.8
3.9
6.6
5.5
5.7
8.8
7.3
7.5
10
8.3
8.6
25
21
21
16
13
14
15
13
13
20
17
17
21
17
18
55
46
47
29
24
25
29
24
25
91
76
78
54
45
46
54
45
46
100
83
85
180
150
154
140
117
120
240
200
206
CK3M
CK3T
CK3R
CK3MG
CKF3M
CKF3R
CKF3MG
CKF3RG
CK3M
CK3T
CK3R
CKF3M
CKF3R
Model
0.001, 0.01, 0.02
0.15, 1.5, 3
0.001, 0.01*
0.15, 1.5*
P Minimum Opening Differential Pressure
Fluorine Rubber (FPM)
TMO 150°C (302°F)
CK3R
Special use
As a vacuum breaker**
MPa
psi
MPa
psi
15
( )
20
( )
25
(1)
32
(1 )
40
(1 )
50
(2)
65
(2 )
80
(3)
100
(4)
2
1
/
2
1
/
2
1
/
4
1
/
4
3
/
2
1
/

1. Avoid installing check valves within a short distance after ON-OFF or extremely quick opening
valves as they may create shock or hammer conditions which could shorten check valve life.
Rapid pulsation or strong shocks to internal parts may result in spring damage or premature
wear on the valve disc and seating surfaces. To improve operation, install the check valve
further away from any quick opening valves to provide additional piping volume. Extra
distance and volume can allow the system pressure to adjust gradually, thereby reducing
surges and potential shock on the check valves.
2. Be sure to choose the model that meets operating temperature requirements as shown below:
3. Before installation, be sure to remove all protective seals.
4. Before installing the product, blow out the inlet piping to remove all dirt and oil.
5. The product can be installed horizontally or vertically, but vertical installation is recommended.
6. Install the product so the arrow on the body is pointing in the direction of flow.
7. Make sure the weight of the outlet piping does not place an excessive load on the product.
8. CKF3M, CKF3R, CKF3MG and CKF3RG are flangeless models, with an easy-to-center design.
To center, install with the fins touching the bolts.
A visual inspection can be carried out to aid in determining the necessity for immediate
maintenance or repair. Periodically (at least biannually) the operation should be checked using
diagnostic equipment such as a stethoscope.
4. Proper Installation
5. Operational Check
Operational inspections should be performed at least twice per year, or as called for by the check
valve operating conditions.
6. Inspection and Maintenance
• Installation, inspection, maintenance, repairs, disassembly, adjustment
and valve opening/closing should be carried out only by trained
maintenance personnel.
• Do not use excessive force when connecting threaded pipes to the product. Over-tightening
may cause brHakage leading to fluid discharge, which may cause burns or other injury.
• Install for use under conditions in which no freeze-up will occur.
CAUTION
• Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
• When disassembling or removing the product, wait until the internal pressure
equals atmospheric pressure and the surface of the product has cooled to room temperature.
• Be sure to use the proper components and NEVER attempt to modify the product.
CAUTION
Max. Flow Temp. ºC (ºF)
Model
90 (194)
CK3R*
350 (662)
CKF3M
CKF3MG
220 (428)
CK3M
CK3MG
185 (365)
CK3T
150 (302)
CKF3R
CKF3RG
Where inlet pressure is higher than outlet pressure (equal to or greater than the
minimum opening differential pressure), flow, in the proper direction, can be verified.
If outlet pressure becomes higher than inlet pressure, flow ceases.
There is flow even when outlet pressure becomes higher than inlet pressure.
Leakage:
Gaskets
Valve Disc, Inlet Union Sealing Surfaces
Coil Spring, Spring Holder (after cleaning inside the body)
Check for warping or damage
Check for scratches
Check for scratches or wear
Normal:
Fin
Bolt
Parts Inspection Procedure
Tightening Torque and Distance Across Flats
Model
Size
CK3M / CK3T / CK3R
15
20
25
32
40
50
80
( )
( )
(1)
(1 )
(1 )
(2)
(3)
100
150
180
250
300
400
27
32
41
50
55
70
(73)
(110)
(130)
(185)
(220)
(290)
(1 )
(1 )
(1 )
(1 )
(2 )
(2 )
Torque Distance Across Flats
CK3MG
180
600
800
800
41
60
75
100
(130)
(440)
(590)
(590)
(1 )
(2 )
(2 )
(3 )
Torque Distance Across Flats
* Model CK3R with optional disc inlay ring of FPM rubber can be used to 150 ºC (302 ºF).
mm (in) mm (in) mm (in)N•m (lbf•ft) N•m (lbf•ft)
1 N•m ≈10 kg•cm
2
1
/
16
1
/
4
1
/
4
3
/
8
5
/
32
31
/
8
5
/
8
3
/
16
15
/
16
15
/
32
5
/
2
1
/
4
3
/
4
1
/

CK3M / CK3T / CK3R CK3MG
Body Body
Coil Spring
Valve Disc
Union Gasket
Inlet Union
Spring Holder
Coil Spring
Valve Disc
Union Gasket
Inlet Union
Disassembly/Reassembly (to reassemble, follow procedure in reverse)
Inlet Union
Union Gasket
Valve Disc
Coil Spring
Spring Holder
(except CK3MG)
Assembly / disassembly are not possible for these models as special equipment is required.
Accordingly, replacement parts are not available for these models.
Coat threads with anti-seize and tighten to the proper
torque (see torque table on page 11)
Insert, making sure the polished surface is facing the
inlet union
CK3M / CK3T / CK3R: Insert into housing
CK3MG: Place the coil spring on the disc stem
Replace with a new gasket if warped or damaged;
make sure the gasket does not get pinched when
tightening the inlet union
Part During Disassembly
Tightly inserted in
body, DO NOT remove
Remove with a wrench
Remove the union
gasket
Remove the valve disc
Remove the coil spring
During Reassembly
CK3M / CK3T / CK3R / CK3MG
CKF3M / CKF3R / CKF3MG / CKF3RG
Dirt or damage on sealing surfaces or
build-up inside the body
The valve disc is catching due to wear,
dirt, rust, etc.
The spring holder is dislodged
or broken
The union gasket is warped or
damaged
The check valve is subject to stress
from the piping (weight, torsion, etc.)
The valve disc is catching due to wear,
dirt, rust, etc.
Sticking valve and valve seat due to
rust, pipe sealing agent, etc.
Incorrect operating pressure
The coil spring is dislodged or broken
Incorrect inlet union tightening torque
Clean parts
Replace with a new check valve
Replace with a new check valve
The sound of flow can
be heard when the
outlet pressure is
higher than inlet
pressure
Leakage to the
outside of the
check valve
Flow is poor
The valve does not
open at the specified
differential pressure
Cause Remedy
Screwed Flangeless
Problem
If the expected performance is unachievable after installation of the check valve read chapter 4
again and check the following points for appropriate corrective measures.
7. Troubleshooting
Replace with a
new check valve
Replace with a
new coil spring
Replace with a
new gasket
Tighten to the
proper torque
Correct the piping
Clean parts
Clean parts
Adjust by increasing the pressure or
replace with a check valve that has a
larger Cv value
If the valve disc is inlaid with rubber,
it may be the case that the rubber is
sticking to the metal. Contact TLV
for details.

8.
Express Limited Warranty
Subject to the limitations set forth below, TLV Corporation, a North Carolina corporation (“TLV”)
warrants that products which are sold by it or TLV International, Inc., a Japanese corporation
(“TII”), which products (the “Products”) are designed and manufactured by TLV Co., Ltd., a
Japanese corporation (“TLVJ”), conform to the specifications published by TLV for the
corresponding part numbers (the “Specifications”) and are free from defective workmanship
and materials. With regard to products or components manufactured by unrelated third parties
(the “Components”), TLV provides no warranty other than the warranty from the third party
manufacturer(s).
Duration Of Warranty
This warranty is effective for a period of the earlier of: (i) three (3) years after delivery of Products
to the first end user in the case of sealed SST-Series Products for use in steam pressure service
up to 650 psig; (ii) two (2) years after delivery of Products to the first end user in the case of
PowerTrap®units; or (iii) one (1) year afterdelivery of Products to the first end user in the case of
all other Products. Notwithstanding the foregoing, asserting a claim under this warranty must be
brought by the earlier of one of the foregoing periods, as applicable, or within five (5) years after
the date of delivery to the initial buyer if not sold initially to the first end user.
ANY IMPLIED WARRANTIES NOT NEGATED HEREBY WHICH MAY ARISE BY OPERATION OF
LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE AND ANY EXPRESS WARRANTIES NOT NEGATED HEREBY, ARE
GIVEN SOLELY TO THE INITIAL BUYER AND ARE LIMITED IN DURATION TO ONE (1) YEAR
FROM THE DATE OF SHIPMENT BY TLV.
Exclusive Remedy
THE EXCLUSIVE REMEDY UNDER THIS WARRANTY, UNDER ANY EXPRESS WARRANTY OR
UNDER ANY IMPLIED WARRANTIES NOT NEGATED HEREBY (INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE), IS
REPLACEMENT; PROVIDED: (a) THE CLAIMED DEFECT IS REPORTED TO TLV IN WRITING
WITHIN THE APPLICABLE WARRANTY PERIOD, INCLUDING A DETAILED WRITTEN
DESCRIPTION OF THE CLAIMED DEFECT AND HOW AND WHEN THE CLAIMED DEFECTIVE
PRODUCT WAS USED; AND (b) THE CLAIMED DEFECTIVE PRODUCT AND A COPY OF THE
PURCHASE INVOICE IS RETURNED TO TLV, FREIGHT AND TRANSPORTATION COSTS
PREPAID, UNDER A RETURN MATERIAL AUTHORIZATION AND TRACKING NUMBER ISSUED
BY TLV. ALL LABOR COSTS, SHIPPING COSTS, AND TRANSPORTATION COSTS
ASSOCIATED WITH THE RETURN OR REPLACEMENT OF THE CLAIMED DEFECTIVE
PRODUCT ARE SOLELY THE RESPONSIBILITY OF BUYER OR THE FIRST END USER. TLV
RESERVES THE RIGHT TO INSPECT ON THE FIRST END USER'S SITE ANY PRODUCTS
Exceptions To Warranty
This warranty does not cover defects or failures caused by:
1. improper shipping, installation, use, handling, etc., by other than TLV or service
representatives authorized by TLV; or
2. dirt, scale or rust, etc.; or
3. improper disassembly and reassembly, or inadequate inspection and maintenance by other
than TLV or service representatives authorized by TLV; or
4. disasters or forces of nature; or
5. abuse, abnormal use, accidents or any other cause beyond the control of TLV; or
6. improper storage, maintenance or repair; or
7. operation of the Products not in accordance with instructions issued with the Products or
with accepted industry practices; or
8. use for a purpose or in a manner for which the Products were not intended; or
9. use of the Products in a manner inconsistent with the Specifications; or
10. failure to follow the instructions contained in the TLV Instruction Manual for the Product.

CLAIMED TO BE DEFECTIVE BEFORE ISSUING A RETURN MATERIAL AUTHORIZATION.
SHOULD SUCH INSPECTION REVEAL, IN TLV’S REASONABLE DISCRETION, THAT THE
CLAIMED DEFECT IS NOT COVERED BY THIS WARRANTY, THE PARTY ASSERTING THIS
WARRANTY SHALL PAY TLV FOR THE TIME AND EXPENSES RELATED TO SUCH ON-SITE
INSPECTION.
Exclusion Of Consequential And Incidental Damages
IT IS SPECIFICALLY ACKNOWLEDGED THAT THIS WARRANTY, ANY OTHER EXPRESS
WARRANTY NOT NEGATED HEREBY, AND ANY IMPLIED WARRANTY NOT NEGATED
HEREBY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, DO NOT COVER, AND NEITHER TLV, TII NOR TLVJ WILL IN
ANY EVENT BE LIABLE FOR, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING,
BUT NOT LIMITED TO LOST PROFITS, THE COST OF DISASSEMBLY AND SHIPMENT OF
THE DEFECTIVE PRODUCT, INJURY TO OTHER PROPERTY, DAMAGE TO BUYER’S OR THE
FIRST END USER’S PRODUCT, DAMAGE TO BUYER’S OR THE FIRST END USER’S
PROCESSES, LOSS OF USE, OR OTHER COMMERCIAL LOSSES. WHERE, DUE TO
OPERATION OF LAW, CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS
WARRANTY, UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR
UNDER ANY IMPLIED WARRANTY NOT NEGATED HEREBY (INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE)
CANNOT BE EXCLUDED, SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE
PURCHASE PRICE OF THE DEFECTIVE PRODUCT. THIS EXCLUSION OF CONSEQUENTIAL
AND INCIDENTAL DAMAGES, AND THE PROVISION OF THIS WARRANTY LIMITING
REMEDIES HEREUNDER TO REPLACEMENT, ARE INDEPENDENT PROVISIONS, AND ANY
DETERMINATION THAT THE LIMITATION OF REMEDIES FAILS OF ITS ESSENTIAL
PURPOSE OR ANY OTHER DETERMINATION THAT EITHER OF THE ABOVE REMEDIES IS
UNENFORCEABLE, SHALL NOT BE CONSTRUED TO MAKE THE OTHER PROVISIONS
UNENFORCEABLE.
Exclusion Of Other Warranties
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL
OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY
DISCLAIMED.
Severability
Any provision of this warranty which is invalid, prohibited or unenforceable in any jurisdiction
shall, as to such jurisdiction, be ineffective to the extent of such invalidity, prohibition or
unenforceability without invalidating the remaining provisions hereof, and any such invalidity,
prohibition or unenforceability in any such jurisdiction shall not invalidate or render
unenforceable such provision in any other jurisdiction.
13901 South Lakes Drive, Charlotte, NC 28273-6790, U.S.A.
Tel: [1]-704-597-9070 Fax: [1]-704-583-1610
10

Printed on recycled paper.
Tel: [81]-(0)79-422-1122
Fax: [81]-(0)79-422-0112
Rev. 8/2020 (M)PAC-65339-a
881 Nagasuna, Noguchi, Kakogawa,
Hyogo 675-8511, Japan
Manufacturer:
Other manuals for CK3 Series
1
This manual suits for next models
8
Table of contents
Other TLV Control Unit manuals
Popular Control Unit manuals by other brands

Honeywell
Honeywell VS8420 installation instructions

Wöhner
Wöhner CRITO 185Power manual

e-con Systems
e-con Systems See3CAM CU30 Getting started manual

urmet domus
urmet domus DIGIVOICE K-Steel 1038/16 Guide

WHITECROFT LIGHTING
WHITECROFT LIGHTING Command Plus Installation and commissioning instructions

M-system
M-system 61F instruction manual