INITIAL CHECK-UP OF CI-600
START
Connect IN/OUT lines, power lines and speech IN/OUT lines to both the exchange and CI-600.
Using the RS-232C cable, connect Cl-600's RS-232C connector No. 1 to
personal computer or data terminal.
Set both MODE SELECT and BAUD RATE DP switches.
(Refer to the operating instructions.)
Set personal computer or data terminal in accordance with the Cl-600's
format. (Refer to the operating instructions.)
• Make sure that power is
supplied.
• Set reset switch (MODE
SELECT switch No.7) to ON.
Switch on the CI-600.
Does the timer LED blink at
1-second interval ?
NO
YES
Does the monitor display initial set-up menu ?
YES
NO
Can characters typed from a
keyboard be correctly displayed
on the screen ?
Confirm that the RS-232C
connector is connected properly.
NO
YES
Recheck if MODE SELECT
switch NQ 7 is set to OFF. *
Confirm that the communication
format of personal computer or
data terminal matches that of
CI-600.
The section "Initial setting" of
operating instructions.
IMPORTANT
Leaving the switch on will cancel all
the stored data when power is
switched again.
-