Transcension DMX 512 MERGER BOTE61 User manual

User manual
TRANSCENSION
Show Control
DMX 512 MERGER
(Order code: BOTE61)
www.prolight.co.uk

User manual
Warnings

User manual
Warnings
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused
by the non-observance of this manual or any unauthorised modication to the
equipment.
•Neverletthepower-cablecomeintocontactwithothercables.Handlethe
power-cableandallmainsvoltageconnectionswithparticularcaution!
•Neverremovewarningorinformativelabelsfromtheequipment.
•Donotopentheequipmentanddonotmodifytheequipment.
•Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethe
system’slife.
•Onlyusetheequipmentindoors.
•Donotexposetoammablesources,liquidsorgases.
•Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbefore
cleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypulling
thepower-cable.
•Makesurethattheavailablevoltageisbetween220v/240v.
•Makesurethatthepower-cableisnevercrimpedordamaged.Checktheequipment
andthepower-cableperiodically.
•Iftheequipmentisdroppedordamaged,disconnectthemainspower
supplyimmediately.
Haveaqualiedengineerinspecttheequipmentbeforeoperatingagain.
•Iftheequipmenthasbeenexposedtodrastictemperatureuctuation(e.g.after
transportation),donotswitchitonimmediately.Thearisingcondensationmight
damagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroom
temperature.
•Ifyourproductfailstofunctioncorrectly,discontinueuseimmediately.Packtheunit
securely(preferablyintheoriginalpackingmaterial),andreturnittoyourProlight
dealerforservice.
•Onlyusefusesofsametypeandrating.
•Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualied
technician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.
•WARRANTY;Oneyearfromdateofpurchase.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,
theproductmaysufferdamageandthewarrantybecomesvoid.
Incorrectoperationmayleadtodangere.g.:short-circuit,burns,electricshocks,
lampfailureetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleandproperty.

User manual
Functions and Controls
Over view
WhenunitisswitchedonthePowerLEDwillilluminate.
WhenDMXinputs“A”and“B”haveapresentsignal,bothoftheDMXinputLEDswillilluminate.
ToturntheunitOnorOff,usethePowerswitchonfrontpaneloftheunit.
Connectyourlightingcontrollersintothe3-pinor5-pinmaleXLRsockets.
Usethe3-pinor5-pinfemaleXLRsockettoconnectintotherstDMXunitinline.
TheDMXMergermergestwoDMXsignalinputs,tooneoutput.Threeoperation
modescanbeselectedbyusingthe2dipswitchsetting.Thethreeoperationmodes
includeHTP(HighestTakesPriority),Backup/LTPandMergemode.WhensettoHTP
modethecontrollerwiththehighestchanneloutputsettingwilltakepriorityonoutput.
HTPisthemostcommonlyusedtocontrollerdimmerchannels.WhensettotheBack
up/LTPmode,acontrollerthatisconnectedtothe“B”DMXinputwillbeonstandby
andwillonlytakeoverifthecontrollerconnectedtothe“A”DMXinputfails.When
settoMergemode,thecontrollersignalscomingintothe“A”and“B”DMXinputswill
mergetooneoutput.Thereare10dipswitchesavailablesothestartingDMXaddress
channelcanbesetforthecontrollerthatisconnectedintoDMXinput“B”.
Forexample,astagedesk16isconnectedtotheDMXinput“A”,wewouldpatchthe
controllerthatisconnectedtoDMXinput“B”atchannel17andalsosetthebinaryon
theDMXmergerto17.
Note: Only 1 input can be used on input “A” and input “B” simultaneously. You
can not use both 3-pin and 5-pin sockets on the same input at the same time.
3/5-pinDMXAinputs
AandBDMX
InputsignalLEDs
PowerLED
PowerOn/offSwitch
Dipswitches PowerInput
ON
OFF
POWER A
DMX
B
DMX OUT
POWER
INPUT
DIPSWITCHES
www.prolight.co.uk
DC 9V~500MA
FRONT
1 = GROUND
2 = DATA -
3 = DATA +
4 = N/A
5 = N/A
1 = GROUND
2 = DATA -
3 = DATA +
4 = N/A
5 = N/A
ON
OFF
POWER A
DMX
B
DMX OUT
POWER
INPUT
DIPSWITCHES
www.prolight.co.uk
DC 9V~500MA
FRONT
1 = GROUND
2 = DATA -
3 = DATA +
4 = N/A
5 = N/A
1 = GROUND
2 = DATA -
3 = DATA +
4 = N/A
5 = N/A
3/5-pinDMXoutputs
3/5-pinDMXBinputs
3/5-pinDMXoutputs
3/5-pinDMXBinputs 3/5-pinDMXAinputs

User manual
Operations
HTP Mode
TosettheunitintotheHTP(HighestTakePriority)mode,setdip
switch1and2tothe“ON”position.
WhentwoDMXsignalsarepresent,thehigherDMXvaluesforeach
channels(1-512)willtakeplace.Thismayallowforsomechannelsof
DMXinput“A”controllertobeactiveandotherchannelsfromDMX
input“B”controllertobeactive.
Back Up and Latest Takes Priority (LTP) Mode
TosettheunitintotheBackup/LTPmode,setdipswitch1and2to
the“OFF”position.TheunitwillnowbeintheBackup/LTPmode.
WhenDMXsignal“A”ispresent,itwilltaketheDMXoutputpriority.
WhenDMXsignal“A”islost,theDMXsignal“B”willtakeoverthe
Priority.
Merge Mode
TosettheunitintoMergemode,setdipswitches1to“ON”and2to
the“OFF”position.
Theunitwillnowbeinthemergemode.
Youcanmergeboth“A”and“B”signalintoaoneDMXoutput.You
mustsetthestartingDMXaddressforthecontrollerthatisconnected
toinput“B”withdipswitches1-9.
Note: If you set dip switch 1 to “ON” and all others to the “OFF”
position, all DMX channel output will start with the rst channel of
DMX signal “B”.

User manual
DMX Operation
DMX-512:
•DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunication
betweenintelligentxturesandcontrollers.ADMXcontrollersendsDMXdata
instructionsformthecontrollertothexture.DMXdataissentasserialdatathat
travelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”XLRterminalslocated
onallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX Linking:
•DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobe
linkedtogetherandoperatefromasinglecontroller,aslongasallxturesandthe
controllerareDMXcompliant.ToensureproperDMXdatatransmission,whenusing
severalDMXxturestrytousetheshortestcablepathpossible.Theorderinwhich
xturesareconnectedinaDMXlinedoesnotinuencetheDMXaddressing.For
example;axtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMX
line,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigned
aDMXaddressof1,theDMXcontrollerknowstosendDATAassignedto
address1tothatunit,nomatterwhereitislocatedintheDMXchain.
Figure 1
Also remember that DMX cable must be daisy chained and cannot be split.

User manual
DMX Operation
Notice:
•Besuretofollowgures2&3whenmakingyourowncables.Donotconnectthe
cable’sshieldconductortothegroundlugorallowtheshieldconductortocomein
contactwiththeXLR’soutercasing.Groundingtheshieldcouldcauseashortcircuit
anderraticbehaviour.
Special Note: Line termination:
•Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelast
unittoavoiderraticbehaviour.
Using a cable terminator (part number CABL90) will decrease the possibilities of
erratic behaviour.
5-Pin XLR DMX Connectors:
•Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof
3-pin.5-PinXLRxturesmaybeimplementedina3-pinXLRDMXline.Whenin
sertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbe
used.Thechartbelowdetailsthecorrectcableconversion.
Termination reduces signal transmission problems
and interferance. it is always advisable to connect a
DMX terminal, (resistance 120 Ohm 1/4 W) between
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

User manual
DMX Chart
DipSwitchDMXAddressChart
Dip Switch Position DMX ADDRESS
Table of contents
Other Transcension Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

SICK
SICK C 4000 operating instructions

Vision & Control
Vision & Control LDLF30x360-R633/UDC Instructions for use

Lightolier
Lightolier Lytecaster 2011 specification

GE
GE Cync CFIXCNLR4S1 installation guide

Fulham
Fulham FireHorse FHEM10WHU General installation guidelines

Viabizzuno
Viabizzuno square system 1600 instructions