Trotec TTK 32 E User manual

TRT-BA-TTK32E-TC221216TTRT01-006-EN
TTK 32 E
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER

2 EN
dehumidifier TTK 32 E
Table of contents
Notes regarding the instructions .........................................2
Safety .....................................................................................2
Information about the device................................................5
Transport and storage...........................................................6
Assembly and start-up..........................................................7
Operation ...............................................................................8
Errors and faults..................................................................11
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................18
Notes regarding the instructions
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to extremely flammable gas.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
TTK 32 E
https://hub.trotec.com/?id=41872
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged
from 8years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Do not cover the device during operation.
• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals.
• Occasionally observe the device during operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 3
dehumidifier TTK 32 E
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.
• Insert the mains plug into a properly fused mains socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Never insert any objects or limbs into the device.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
• Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.
Safety warnings for devices containing flammable
refrigerants
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate. Unventilated rooms, in
which the device is installed, operated or stored, must be
built in a way to ensure that potentially leaking refrigerant
cannot accumulate. This serves to avoid fire or explosion
hazards resulting from an ignition of the refrigerant by an
electric furnace, cooking stove or another ignition source.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Please note that the refrigerant is odourless.
• Only install the device in compliance with the national
installation regulations.
• Please observe the local regulations.
• Observe the national gas regulations.
• Only install, operate and store the device in a room
measuring more than 4m2.
• Store the device in a way that no mechanical damage can
occur.
• Please note that the connected pipelines must not contain
any sources of ignition.
• R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
• Observe the maximum refrigerant capacity in the technical
data.
• Do not drill through or burn.
• Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
• Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
• Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.

4 EN
dehumidifier TTK 32 E
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms and basements
– holiday homes, camper vans
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– changing rooms etc.
Foreseeable misuse
• The device is not intended for industrial use.
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device out of doors.
• This device must not be used in wet rooms (e.g. laundry
rooms).
• Never immerse the device in water.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Follow the manual
This symbol indicates that the instructions must be
observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.

EN 5
dehumidifier TTK 32 E
Residual risks
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. Disconnect the device from the mains feed-in: Hold onto
the mains plug while pulling the power cable out of the
mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Device description
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operation) on the control panel is illuminated. The device
switches off. The condensation tank indicator light only goes out
again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

6 EN
dehumidifier TTK 32 E
Device depiction
2
4
5
10
11 1
6
9
3
3
3
7
8
No. Designation
1 Transport handle
2 Air outlet
3 Wheels
4 Air inlet with air filter
5 Condensation drain hose connection
6 Power cable holder
7 Air filter
8 Condensation drain hose
9 Recessed compartment for mains plug
10 Condensation tank with filling level indicator
11 Control panel
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Please note that additional transport regulations might apply to
devices containing flammable refrigerants. The equipment's
arrangement and the maximum number of components to be
transported together can be gathered from the applicable
transport regulations.
To make the device easier to transport, it is fitted with a carry
handle.
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Do not use the power cable to drag the device.
• Only wheel the device on firm and level surfaces.
After transporting the device, proceed as follows:
• Set up the device in an upright position after transport.

EN 7
dehumidifier TTK 32 E
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
When the device is not being used, observe the following
storage conditions:
• Only store the device in a room measuring more than 4m2.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Store the device in a dry location and protected from frost
and heat.
• Store the appliance in an upright position where it is
protected from dust and direct sunlight.
• If required, use a cover to protect the device from invasive
dust.
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and start-up
Scope of delivery
• 1x Device
• 1x Condensation drain hose, length:0.6m,
diameter:13.5 mm
• 1x Air filter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
• Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
• Only put up the device in an upright, stable position on firm
ground.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.

8 EN
dehumidifier TTK 32 E
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
• Ensure that the float inside the condensation tank is
inserted correctly.
• Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.
Info
When connecting the power cable, the LEDs in the
control panel briefly light up in red or green.
Operation
Notes:
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The fan continues to run in dehumidification mode for
3minutes after the selected setpoint has been reached.
Operating elements
13 14 19
18
17
16
15
12
No. Designation Meaning
12 Tank full LED Is displayed when the
condensation tank is full or not
installed correctly
13 Defrost LED Is displayed when automatic
defrosting is in progress
Flashes if an error has occurred
at the device
14 Operation LED Illuminated during continuous
operation
15 Relative humidity 40%
indication
Illuminated during
dehumidification (relative
humidity 40%)
16 Relative humidity 50%
indication
Illuminated during
dehumidification (relative
humidity 50%)
17 Relative humidity 60%
indication
Illuminated during
dehumidification (relative
humidity 60%)
18 Operating modes button Selection button for operating
modes:
Continuous operation mode
Dehumidification (relative
humidity 40%)
Dehumidification (relative
humidity 50%)
Dehumidification (relative
humidity 60%)
19 Power button Switching the device on or off

EN 9
dehumidifier TTK 32 E
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Press the power button(19).
Setting the operating mode
• Dehumidification
• Continuous operation
Setting the desired relative room humidity
The desired relative room humidity can be preselected at any
time.
1. Press the operating modes button(18) to set the desired
room humidity. The setting range covers 40%, 50% and
60%.
Dehumidification
The device runs until the desired relative room humidity is
reached. Then the compressor switches off and the fan
continues to run for another 3minutes before it switches off.
Once the desired relative room humidity is exceeded, the
compressor and fan switch back on.
The desired relative room humidity can be set at any time, the
setting range covers 40%, 50% and 60%.
1. Press the operating modes button(18) until the desired
room humidity is displayed.
ðThe indication for the desired relative humidity level(15,
16, 17) is illuminated.
ðThe desired relative room humidity is selected.
Continuous operation mode
The device dehumidifies the air constantly and regardless of the
relative room humidity.
The desired relative room humidity cannot be adjusted in this
operating mode.
1. Press the operating modes button(18) until the Operation
LED(14) is illuminated.
ðContinuous operation is selected.
Info
For continuous operation the condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.
Memory function
After a power failure during operation the device will
automatically be switched back on. The selected settings are
saved.
If the device was disconnected from the mains for a longer time,
the device starts in continuous operation mode when it is
switched back on.
Auto stop function
If the water tank is full, not inserted correctly or the relative
room humidity has been reached, the device will stop
automatically.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
üA suitable hose (diameter: 13.5mm) is ready for use.
üThe device is switched off.
1. Remove the rubber plug.

10 EN
dehumidifier TTK 32 E
2. Push one end of the hose onto the hose connection.
3. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
The hose can be connected in any operating mode for
continuous operation.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
The Defrost LED(13) is illuminated.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The following humidity values are suitable for drying laundry:
• cupboard dry= 46% relative humidity
• iron dry= 58% relative humidity
• slightly dried= 65% relative humidity
Adjust the settings for the relative humidity level to the device
(e.g. 60% relative humidity for iron dry laundry). If necessary,
use a measuring device to determine the humidity level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.

EN 11
dehumidifier TTK 32 E
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damage.
• Check the on-site fusing.
• Check the filling level of the condensation tank and empty
it if necessary. The condensation tank full indication(12)
must not light up.
• Check the condensation tank for correct seating.
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
• Check whether the automatic defrost indication(13)
flashes (see Error codes).
The device is running, but there is no formation of
condensate:
• Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
• Ensure that the relative room humidity complies with the
technical data.
• Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
• Check the air filter for dirt. If necessary, clean or replace
the air filter.
• From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
• The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
• Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
• Check the device for leaks.
The compressor does not start:
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
• Ensure that the relative room humidity complies with the
technical data.
• Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
• Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
• The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filters for dirt. Remove external
dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note
Wait for at least 3minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The Defrost LED(13) can denote the following error messages:
Error code Cause Remedy
Flashing slowly Leaking refrigerant Switch the device off
and contact the
customer service.
Flashing
quickly
Error at the room
temperature sensor
Error at the
temperature sensor
of the evaporator
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the
restart, please contact
the customer service.

12 EN
dehumidifier TTK 32 E
Maintenance Maintenance intervals
Maintenance and care interval before every
start-up
as needed at least every
2weeks
at least every
4weeks
at least every
6months
at least
annually
Check air inlet and outlet for dirt
and foreign objects and clean
ifnecessary
X X
Clean the exterior X X
Visually check the inside of the
device for dirt
X X
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
X X
Replace the air filter X
Check for damage X
Check the attachment screws X X
Test run X
Empty and clean the condensation
tank and/or drain hose
X
Maintenance and care log
Device type: ............................................. Device number: ....................................
Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Check air inlets and outlets for dirt
and foreign objects and clean
ifnecessary
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
Clean the exterior
Visually check the inside of the
device for dirt
Replace the air filter
Check the attachment screws
Test run
Empty and clean the condensation
tank and/or drain hose
Comments
1. Date: ......................................
Signature: ..................................
2. Date: ......................................
Signature: ...................................
3. Date: ......................................
Signature: ..................................
4. Date: ......................................
Signature: ...................................
5. Date: ......................................
Signature: ..................................
6. Date: ......................................
Signature: ...................................
7. Date: ......................................
Signature: ..................................
8. Date: ......................................
Signature: ...................................
9. Date: ......................................
Signature: ..................................
10. Date: ....................................
Signature: ...................................
11. Date: ....................................
Signature: ..................................
12. Date: ....................................
Signature: ...................................
13. Date: ....................................
Signature: ..................................
14. Date: ....................................
Signature: ...................................
15. Date: ....................................
Signature: ..................................
16. Date: ....................................
Signature: ...................................

EN 13
dehumidifier TTK 32 E
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Refrigerant circuit
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
5. Put the air filter back in.
Cleaning the air filter
Note
Ensure that the air filters are neither worn nor
damaged. The corners and edges of the air filters must
not be deformed or rounded. Before reinserting the air
filters, make sure that they are undamaged and dry!
The air filters have to be cleaned as soon as they are dirty. This
is brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
1. Remove the air filter from the device.

14 EN
dehumidifier TTK 32 E
2. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
Tank full LED(12) will be illuminated. The compressor and fan
will switch off.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).

EN 15
dehumidifier TTK 32 E
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
Also make sure that the condensation tank is inserted
correctly, otherwise the device cannot be switched back
on.
Activities required after maintenance
If you want to continue using the device:
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter Value
Model TTK32E
Max. dehumidification
performance
12l/ 24h
Air flow rate 118 m3/h
Operating range (temperature) 5 °C to 32 °C
Operating range
(relative humidity)
35% to 85% RH
Pressure suction side 1MPa
Pressure outlet side 2.6MPa
Max. permissible pressure 2.6MPa
Mains supply 220 – 240V/ 50Hz
Fusing T 3.15A / 250VAC
Type of protection IPX0
Max. power consumption 0.35kW
Nominal current 1.4A
Refrigerant R-290
Amount of refrigerant 50g
GWP factor 3
CO2 equivalent 0.00015t
Water tank 2.1 l
Sound pressure level 46 dB(A)
Dimensions (lengthx widthx
height)
215 x 320x 420mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
40 cm
20 cm
20 cm
20 cm
Weight 11kg

16 EN
dehumidifier TTK 32 E
Wiring diagram

EN 17
dehumidifier TTK 32 E
Overview of spare parts Note: The position numbers of the spare parts differ from those
describing the positions of the components mentioned in these
instructions.
Spare parts list
No. Spare Part No. Spare Part No. Spare Part
1 Water Tank Assembly 3.5 Electronic Control Box 9 Suction Pipe Assembly
1.1 Water Tank Subassembly 3.6 Dehumifier Main Control Board Subassembly 10 Capillary Assembly
1.1.1 Dobber Case 3.7 Humidity Sensor Subassembly 11 Condenser Assembly
1.1.3 Water Tank 3.8 Supporter Of Fan Motor 12 Evaporator Assembly
1.2 Water Tank Subassembly 4 Middle Partition Board Assembly 13 Discharge Pipe Assembly
2 Front Panel Assembly 4.1 Partition Board 14 Rear Panel Assembly
2.1 Front Panel 4.2 Micro Switch 14.1 Rear Panel
2.2 Display Box Subassembly 4.3 Fan Motor Capacitor 14.2 Drain Stopper
2.3 Top Cover Subassembly 5 Chassis Assembly 15 Air Inlet Grille
3 Volute Shell Assembly 5.2 Wheel 16 Cover Of Electronic Control Box
3.1 Centrifugal Fan 6 Power Cord Subassembly 25 Drain Pipe
3.2 Single Phase Asynchronous Motor 7 Pipe Temperature Sensor
3.3 Volute Shell Subassembly 8 Fixed Speed Reciprocating Compressor

18 EN
dehumidifier TTK 32 E
Disposal
Always dispose of packing materials in an environmentally
friendly manner and in accordance with the applicable local
disposal regulations.
The icon with the crossed-out waste bin on waste
electrical or electronic equipment is taken from Directive
2012/19/EU. It states that this device must not be disposed of
with the household waste at the end of its life. You will find
collection points for free return of waste electrical and electronic
equipment in your vicinity. The addresses can be obtained from
your municipality or local administration. You can also find out
about other return options that apply for many EU countries on
the website https://hub.trotec.com/?id=45090. Otherwise,
please contact an official recycling centre for electronic and
electrical equipment authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
Have the refrigerant (propane) disposed of appropriately and
according to the national regulations by a company with the
relevant certification (European Waste Catalogue 160504).
Only for United Kingdom
According to Waste Electrical and Electronic Equipment
Regulations 2013 (SI2013/3113) (as amended) devices that are
no longer usable must be collected separately and disposed of
in an environmentally friendly manner.

Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec MD 01-10 User manual

Trotec
Trotec TTR 200 User manual

Trotec
Trotec TTK 27 HEPA User manual

Trotec
Trotec TTK 175 S User manual

Trotec
Trotec TTR 50 E User manual

Trotec
Trotec TTR 250 EX User manual

Trotec
Trotec 1120000035 User manual

Trotec
Trotec TTK 655 S User manual

Trotec
Trotec TTK 26 E User manual

Trotec
Trotec TTK 1500 User manual

Trotec
Trotec TTR 800 User manual

Trotec
Trotec TTK 60 E User manual

Trotec
Trotec TTR 400 User manual

Trotec
Trotec TTP 5 E User manual

Trotec
Trotec TTK 90 E User manual

Trotec
Trotec TTK 96 E User manual

Trotec
Trotec TTK 140 S User manual

Trotec
Trotec TTK 54 E User manual

Trotec
Trotec ttk 71 e User manual