8
Placing Truma AquaGo™ instant
water heater in operation
Danger of over-temperature and toxic ex-
haust gases!
• Use with LP gas (propane) only. Butane or
any mixtures containing more than 10% bu-
tane shall not be used.
• Keep the air inlet and exhaust gas outlet
free of obstructions. Do not lean any ob-
jects against the water heater’s access door
or place any foreign objects within 2feet
(61cm) of the access door.
Danger of combustion, personal injury
and damage to RV!
• Keep the area around the Truma AquaGo™
instant water heater free from combustible
materials, gasoline, and other flammable va-
pors or liquids.
• Switch the gas supply and the Truma
AquaGo™ instant water heater off:
– if anything seems to be out of the ordinary.
– if you smell gas.
– if you move the RV.
– before entering a gas station.
– before entering a tunnel.
Inspections before each use
Check the Truma AquaGo™ instant water heater
for the following points before each use. In
case of damage, contact an authorized Tru-
ma service provider and do not operate the
Truma AquaGo™ instant water heater.
1. Check for visible damage, e.g., on the cover
plate or access door.
2. Access to adequate quantities of LP gas
(Fuel inlet pressure 10.5" – 14" wc (26.2 –
34.9mbar)), 12 V power, and water must be
available.
3. The access door must be closed.
4. Keep the Truma AquaGo™ instant wa-
ter heater free of foreign objects, e.g.,
leaves, animals, spiderwebs, and keep
the area around free of snow and ice. The
Truma AquaGo™ instant water heater will
not function properly if the intake air or ex-
haust terminal is obstructed.
Operating procedures
Proceed as follows to fill the Truma AquaGo™
instant water heater with water:
1. Close open bypass lines (if present).
2. Turn on fresh water supply or switch on wa-
ter pump.
3. Fill the plumbing system.
• Open all water-release points, e.g., cold
and hot water faucets, showers, toilets.
• Once water flows, the plumbing system is
ventilated. Close the water-release points.
Place the Truma AquaGo™ instant water heater
into operation as follows:
4. Make sure that the LP gas supply is turned
on.
5. Switch on the 12 V power supply.
6. Open the access door (refer to “Opening the
access door” on page 7).
7. Switch on the Truma AquaGo™ instant wa-
ter heater at mode switch. Refer to “Operat-
ing modes” on page 9 for modes available
with your model.
8. Close the access door (refer to “Closing the
access door” on page 7).
Scalding injuries caused by hot water!
Water temperatures over 127ºF (52ºC) can
cause severe burns or scalding and in extreme
cases even death.
• Before using hot water faucet or using the
shower, allow the hot water to run until the
water temperature no longer increases.
• Test the temperature of the water before
placing a child in the bath or shower.
• Do not leave a child or an infirm person in
the bath unsupervised.
• There may be a variation between
the temperature delivered from the
Truma AquaGo™ instant water heater and
the temperature at the faucet due to water
conditions or the length of pipe from the
Truma AquaGo™ instant water heater.
• The presence of a flow restrictor in the hot
water line may Iimit the water flow.
9. How to use hot water:
• To obtain the desired water temperature at
the faucet or in the shower, mix cold and
hot water.
• Particularly when showering, wait until the
water temperature has stabilized before en-
tering or allowing other people or animals
to enter the shower.