TUYA CS01W/12-2020/V00 User manual

WIFI SMOKE AND CARBON MONOXIDE
DETECTOR
Quick Reference Guide
CS01W/12-2020/V00
Thank you for purchasing our intelligent wifi smoke and carbon monoxide
combination alarm device. Please read this manual carefully to ensure
proper use and store it in a safe place for future reference.
Product Specifications
Power: DC 2*1.5V AA Alkaline (LR6、MN1500)
Operation Current: <15uA (standby); <70mA (alarm)
Alarm Volume: >85 dB(A) at 3 meters
Smoke Sensitivity: 0.09 - 0.17 dB/m
CO sensitivity: 50ppm 60~90min
100ppm 10~40min
300ppm ≤3min
Low Battery: 2.6 ± 0.1 V
Silence Time: approx. 10 minutes
Wi-Fi connectivity:802.11 b/g/n @2.4G
Comply to Standard 1: EN14604:2005/AC:2008 (for smoke detector)
Comply to Standard 2: EN50291:2010 (for carbon monoxide detector)
Packing List
1 × smoke and carbon monoxide alarm
1 × Mounting bracket
1 × Screw Kit
1 × User manual

Product profile:
Installation Instructions
Where to install
1. At first you should install an alarm in the bedroom and walkway. If
there are several bedrooms in the house, please install an alarm in
every bedroom.
2. Install an alarm above the stairway and on every floor of the house.
3. Smoke, heat and burning things will spread horizontally after rising to
the ceiling, so install the alarm in middle of the ceiling.
4. If the alarm can not be installed in the middle of the ceiling, install it
keeping 300mm away from the corners . (see the figure1).
5. If the alarm is installed in the wall, it should keep 100mm away from
the ceiling.
6. If the length of the room or the hall is beyond 30 foot, you need to
install several alarms there.
7. When the wall or ceiling is slanting, the alarm needs to be installed
minimum 500mm away from the highest wall or ceiling point in the
room (see the figure 2).
Figure 1 Figure 2
Figure 3

Locations to Avoid
1. High-humidity areas such as kitchens, and bathrooms;
2. Next to air outlets, fans and central heating;
3. Dusty, dirty areas or areas with insects;
4. High-temperature and easily polluted places;
5. Places with difficult access, making it difficult to operate the test
function;
6. Within 1.5m from lamps;
7. Next to doors or windows;
8. In the top of rooms with sloping roofs, the corner of the room or other
dead-air spaces.
Mounting Alarms
1. Twist off the mounting bracket from the alarm.
2. Put the bracket on the installation position and mark the screw holes
on the ceiling or the wall.
3. Drill two mounting holes in the marked place by an electric drill (The
diameter of the drill hole is 5mm) and insert two plastic anchor plugs
by hammer.
4. Screw the mounting bracket to the ceiling or the wall (Refer to figure
3).
5. Attach the alarm to the mounting bracket and turn clockwise to lock
the alarm
6. If you have any question on installation, please contact your retailer.
WARNING: The installation instructions must be followed strictly in
case of any injury.
Figure 3
Test your Alarm
Test the unit to ensure proper operation by pressing the cover, the alarm will
sound if the unit are working well. If no sounds, you can refer to “Trouble
shooting”section for solution.
CAUTION:
1. DO NOT test your alarm using an open flame. This may damage the
smoke alarm, or ignite combustible materials and start a structural fire.
2. DO NOT stand close to the alarm when the alarm is sounding.
Exposure at close range may be harmful to your earing, so step away
when testing.
3. Weekly Test: test this smoke alarm once a week.

LED and Buzzer Indicators
1. Normal status: Green LED Flashes once every 60 seconds.
2. Test status: Two sets of 3 long beeps with Red LED flashes and two
sets of 4 quick beeps with Red LED flashes.
3. Smoke alarm: Red LED flashes 4 times synchronized with 4 long beeps
4. Carbon monoxide alarm: Red LED flashes 3 times synchronized with 3
short beeps
5. Hush/Silence mode: Red LED flashes once every 8 seconds.
6. Low Battery status: Red LED flashes once every 60 seconds and 1
beep every 60 seconds.
7. Fault status: the alarm will deliver beeps every 40 seconds.
Silence Mode
During the unit is alarming, you can push the test button, it will be paused
the unit alarming for approx 10 minutes. The red LED will flash once every
8 seconds, it indicates the smoke alarm device is running into the silence
mode.The silence feature is to be used only when a known alarm condition,
such as smoke from cooking activates the alarm.The smoke alarm device
will automatically reset after approximately 10 minutes, if after this
period, particles of combustion are still present, the alarm will sound
again.
CAUTION:
Before using the alarm silence (silence), identify the source of the smoke
and be certain a safe condition exists.
Maintenance and Cleaning
There are a few simple steps you need do to keep it working properly.
1、Test the alarm once a week.
2、Clean the alarm surface with a soft brush or cloth every month.
3、Do not paint the alarm. Paint will seal the vents and interfere with the
sensor’s ability to detect smoke.
4、Never attempt to disassemble the alarm to clean inside. This will
In addition to weekly testing, the alarm requires periodic cleaning to
remove dust, dirt, and debris.
Clean the alarm at least once a month to remove dust, dirt, or debris.
Use a vacuum cleaner with the soft brush, vacuum all sides and covers of
smoke alarm device.
If there is a defective battery or other failures, you can refer to “Trouble
shooting” for solution, if there are still failures during warranty, you can
return to your retailer.
IMPORTANT: Do not attempt to remove the cover to clean inside. This will
void warranty.
Replaced Battery:
1. The low battery signal can last for maximum 30 days, please replace
the batteries in time to keep it working properly.
2. Battery required: standard 1.5V AA alkaline batteries. Recommended
battery brand: DURACELL(MN1500,Ultra/Plus) ,Energizer(E91),Golden
Peak,GP, etc; if use low quality battery, it may cause the alarm work
false or reduce service life
3. Correctly install the positive and negative poles of the battery (+ & -)

Trouble Shooting
WiFi function description:
This product uses a low power consumption module with built-in Wi-Fi
connectivity solution designed by Hangzhou Tuya Technology Corporation,
which can connect the product to the Tuya cloud platform. When the
product detected a fire happen, it can automatically push the fire alarm
information to ‘Tuya Smart APP’, reminds users to protect your lives and
property.
Preparation for use
Download and open the app
Search for "Tuya Smart" or "Smart Life " in the application market or scan
the QR code on the outer packaging/instructions to download and install
the App.
For the first download and use, please click the "register" button to
register an account, if you already have an account, click the "login"
button。
Make sure your AP routine is working normally.and your phone is
connected to the Wi-Fi network in the 2.4GHz band;
Tuya Smart APP Smart Life APP
Network access settings
Open the “Tuya Smart” or “Smart Home” App, select the "Smart Home"
page, and click the "+Add Device" button;
On the device addition page, click the "Scan" button in the upper right
Problem
Method of disposal
The alarm does not
sound when testing
Please check whether the batteries be well
assembled according to the Guide required
Red LED flashes and the
alarm delivers one beep
every 60 seconds
The battery is low. Please replace the batteries as
soon as possible.
The alarm delivers one
beep every 40 seconds
1.clean the alarm. Please refer to the
“maintenance and cleaning” section.
2.the alarm is malfunctioning. Contact the retailer
to replace it.
Nuisance alarms
triggered intermittently
or when residents are
cooking, taking showers,
etc.
1.press silence button.
2.clean the alarm. Please refer to the
“maintenance and cleaning”section.
3.move the alarm to new location.
The alarm does not
triggered when other
alarm be triggered
1.check the device if be interlinked.
2. check the distance between the interlinked
alarms out of max allowed distance

corner to scan the QR code below;
Follow the instruction step by step to complete the paring process.
You can choice to paring the network by manual operation at next step:
Paring process(EZ Mode):
Step1: Open the APP enter into "My Home" ,click "Add Device" ;
Step2: Select ”Security & Sensor”,and select ”Alarm (Wi-Fi)”;
Step3: Power o the device, Quickly press the button four times until the LED
indicator light rapidly blinks.Confirm and Click”Next”
Step4: Wait for the device to configure automatically.The paring process
is within 3 minutes ;
Step5: After the configuration is successful, the indicator light stops
blinking, and the APP jumps to "Added successfully". Click "Done" to finish
the paring process.
IF failed to pairing the alarm, please try again or choose the AP Mode to
try it.
Warranty Information
Purchase each new smoke and carbon monoxide alarm device to be free
from defects in material and workmanship under normal use and service
for a period of 2 years from the date of purchase. During the specified
warranty period, we will repair or replace, at its discretion any defective
Alarms that are returned to the retailer. Please include your name,
address and phone number along with a brief description of what is
wrong with the unit. Damage from neglect, abuse or failure to adhere to
any of the enclosed instructions will result in termination of the warranty,
and the unit will not be replaced or repaired.
This warranty shall not apply to the alarm if it has been damaged,
modified, abused or altered after the date of purchase or if it fails to
operate due to improper maintenance.
The Manufacturer shall have no liability for any personal injury, property
damage or any special, incidental, contingent or consequential damage of
any kind resulting from gas leakage, smoke, fire or explosion.