ATLFSG
INSTRUCTION MANUAL
Introduction
The ATLFSG test lead adapter kit lets you use your standard multimeter
(with micro-amps measurement function) to test common
flame-safeguard circuits that use standard 3.5 mm stereo jack.
Safety Notes
Observe all safety precautions when measuring higher voltages. Turn
off the power to the circuit under test. Connect the test leads to the
meter and then to the circuit under test. Reapply power.
WARNING!
When taking current measurements, the multimeter must be connect-
ed in SERIES with the circuit element under test. Never connect the test
leads across a voltage source. To do so may blow the fuse and dam-
age the circuit under test.
Operating Instructions
AC Voltage
To determine the voltage of any energized AC circuit up to 300 volts.
proceed as follows:
1. Set range selector switch to AC volts (700 or higher).
2. Connect the red test lead to the V/Ωinput and the
black test lead to the common input.
3. Attach the meter leads in parallel with the voltage to
be measured (Fig 1).
4. Read meter display.
DC Voltage
To determine the voltage of any energized DC circuit up to 150 V,
proceed as follows:
1. Set range selector switch to DC volts (400 or higher).
2. Attach the meter leads in parallel with the voltage to
be measured (Fig 2).
3. Read meter display.
NOTE: Fig 2 illustrates how flame circuit voltages (instead of current)
are measured on flame safeguard controls using lead sulfide
photocell detectors. (Suitable lead sulfide detector voltage readings
are 100 - 140 V DC).
Meter connections for checking performance of lead sulfide photocell
with R478B or R4074B relay.
Flame Current Check
The flame current is the best indicator of proper flame detector
application. The check should be done at the time of installation, at
any time service is done on the system, and at least once a month or
sooner while the system is in operation. This will prevent shutdowns
due to poor flame signal.
The test is done by connecting your multimeter in series with the flame
detector using µA (microamp) range and reading the flame signal when
the burner is operating.
Insert the ATLFSG red test lead to the “mAµA” jack and the black test
lead to the “COM” jack on the meter and the mini-plug into the test
jack on the RA890F. This automatically puts the meter in series with the
flame detector.
1. For a flame safeguard relay having a flame current jack, such as
RA89E, F, & G, R890E, F, & G, R4138, R4150, R4181, R4795A,
C, D (Fig 3).
(Fig 1)
(Fig 2)
(Fig 3)
ATLFSG-MAN P. 1
(Fig. 5)
2. Insert cable connector plug into flame current jack. This puts the
meter in series with the flame lead. The system must be operating
and detector sighting flame for current to flow through the meter.
Minimum safe current is 2µA (Fig 4).
RA890F and 0270A sub-base
Location of test jack on the RA890F
3. For a flame safeguard relay without flame current test jack, such
as R890, R485, RA1 90B, RA890B & C, R 178, R407A, R7023, W1
24, hook-up (Fig 5).
4. For pulsing-type relay without a flame current test jack, such as
R4075B and some models of R4138A, hook-up (Fig 5). Use the
20µA selector setting and read direct. To stop cycling, manually
hold in relay 2K (2R in older models) and pull out the
vacuum tube.
NOTE: System must be operating and detector sighting flame for
current to flow through the meter.
ATLFSG-MAN P. 2
(Fig 4)
(Fig 5)
5. For pulsing-type flame safeguard relays with the flame current
jack and push-button for eliminating pulses, used with a
self-checking C7012E flame detector, such as R4138A and
R4181A (Fig 6).
6. Insert cable connector plug into flame current test jack to put
meter in series with flame lead (Fig 6). To stabilize meter reading,
hold relay 2K in with one hand, press test push-button with other
hand, read µA scale and release button. When normal pulsing is
reestablished, release relay 2K. A stable reading, with the
push-button depressed and 2K held in, of 4 to 4-1/2 minroamps
is the minimum acceptable flame current.
CAUTION!
To eliminate the possibility of injury to operator and damage to the
instrument and equipment, the following procedure is recommended.
Exercise care and caution on all ranges, particularly the voltage
ranges, and follow all standard published safety rules and wear
appropriate personal protective equipment (ppe). Misuse, abuse and
carelessness cannot be prevented by any written word and is fully the
operator’s responsibility.
(Fig 6)
Limited Warranty
The AT L FSG is warranted to be free from defects in materials and workmanship
for a period of one year from the date of purchase. If within the limited lifetime warranty
period your instrument should become inoperative from such defects, the unit will be
repaired or replaced at UEi’s option. This warranty covers normal use and does not cover
damage which occurs in shipment or failure which results from alteration, tampering, acci-
dent, misuse, abuse, neglect or improper maintenance. Batteries and consequential dam-
age resulting from failed batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the express warranty. UEi shall not be
liable for loss of use of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such damage, expenses or
economic loss. A purchase receipt or other proof of original purchase date will be required
before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired
(when repairable) for a service charge. Return the unit postage paid and insured to:
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: [email protected]
This warranty gives you specific legal rights. You may also have other rights which vary from
state to state.
ATLFSG
Flame Safeguard Relay Test Kit
Copyright © 2007 UEi ATLFSG-MAN 2/07

Other UEi Test Equipment manuals

UEi IRT807 User manual

UEi

UEi IRT807 User manual

UEi C161KIT User manual

UEi

UEi C161KIT User manual

UEi C165 User manual

UEi

UEi C165 User manual

UEi C161 User manual

UEi

UEi C161 User manual

UEi DMEG3/IRT3 User manual

UEi

UEi DMEG3/IRT3 User manual

UEi NCV3 User manual

UEi

UEi NCV3 User manual

UEi NCV3 User manual

UEi

UEi NCV3 User manual

UEi ECT120K User manual

UEi

UEi ECT120K User manual

UEi DT301 User manual

UEi

UEi DT301 User manual

UEi PSMR1 Operating and maintenance manual

UEi

UEi PSMR1 Operating and maintenance manual

UEi DTH1 User manual

UEi

UEi DTH1 User manual

UEi IRT20 User manual

UEi

UEi IRT20 User manual

UEi IRT807 User manual

UEi

UEi IRT807 User manual

UEi AUTOPLUS 4-2 User manual

UEi

UEi AUTOPLUS 4-2 User manual

UEi IRT803 User manual

UEi

UEi IRT803 User manual

UEi CML100 User manual

UEi

UEi CML100 User manual

UEi C160 User manual

UEi

UEi C160 User manual

UEi DL429 User manual

UEi

UEi DL429 User manual

UEi IRT803 User manual

UEi

UEi IRT803 User manual

UEi DL589 User manual

UEi

UEi DL589 User manual

UEi DTH880 User manual

UEi

UEi DTH880 User manual

UEi DMEG3 User manual

UEi

UEi DMEG3 User manual

UEi PSMR1 User manual

UEi

UEi PSMR1 User manual

Popular Test Equipment manuals by other brands

Megger VLF CR-40 operating manual

Megger

Megger VLF CR-40 operating manual

Endress+Hauser nivotester FTL 372-F2E1 manual

Endress+Hauser

Endress+Hauser nivotester FTL 372-F2E1 manual

Leader Electronics Corp. LTC-906 instruction manual

Leader Electronics Corp.

Leader Electronics Corp. LTC-906 instruction manual

Agilent Technologies 85052B User's and service guide

Agilent Technologies

Agilent Technologies 85052B User's and service guide

LaMotte TRACER pH PockeTester 1741 manual

LaMotte

LaMotte TRACER pH PockeTester 1741 manual

GESTRA NRA 1-3 Original Installation Instructions

GESTRA

GESTRA NRA 1-3 Original Installation Instructions

Nuvoton KU-KA44143A user manual

Nuvoton

Nuvoton KU-KA44143A user manual

Rohde & Schwarz RTE1022 user manual

Rohde & Schwarz

Rohde & Schwarz RTE1022 user manual

Apera Instruments LabSen763 user manual

Apera Instruments

Apera Instruments LabSen763 user manual

Agilent Technologies InfiniiVision 6000 Series user guide

Agilent Technologies

Agilent Technologies InfiniiVision 6000 Series user guide

Launch X-431TOP user manual

Launch

Launch X-431TOP user manual

Polymer Technology Systems PTS PANELS HDL user guide

Polymer Technology Systems

Polymer Technology Systems PTS PANELS HDL user guide

Kenwood CS-3035 instruction manual

Kenwood

Kenwood CS-3035 instruction manual

Agilent Technologies 1000B Series user guide

Agilent Technologies

Agilent Technologies 1000B Series user guide

Sanwa HG561H instruction manual

Sanwa

Sanwa HG561H instruction manual

Alcofind AF-50 instruction manual

Alcofind

Alcofind AF-50 instruction manual

pico Technology PicoScope 4444 user guide

pico Technology

pico Technology PicoScope 4444 user guide

Tektronix MDO4000 Series instruction manual

Tektronix

Tektronix MDO4000 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.