
MECHANIC'S INSTRUCTIONS
SETTING THE NEEDLE
BAR
TO
HEIGHT
The lower needle
bar
bushing, the one to which the needle
bar
is
timed,
is
set
at
the factory, the
distance
from
the bottom of bushing (B, Fig.
13)
to the
throat
plate
seat
is
2-9/32
inches.
The four
lines
engraved on the needle
bar
are
used in
setting the
bar
to height and
are
referred
to
as
timing lines.
The upper two
lines
are
used with the
extra
short
length
Type
183
GC
or
183
GL needles which
are
recommended
for
Styles
61400 A, 61400
E,
61400
F,
61400 G, 61400 H, 61400 N,
61400 P.
The lower two
lines
are
used
with the
short
length Type
180
GL
needles which
are
recommended
for
Styles 61400 B,
61400 R, 61400
S.
When the needle
bar
is
at
its
lowest position the upper
timing line (A) of the
pair
selected, dependent on the needle
being used, should be even with the lower edge of the lower
needle
bar
bushing (B). To change the position of the needle
bar
turn
the handwheel until the needle
bar
is
at
its
lowest
position, then loosen clamp screw (D) and move the
bar
to the
proper
timing line. Keeping the needle
bar
link
at
its
lowest
position, retighten
screw
securely.
D
Fig.
13
The
illustration
(Fig.
13)
shows
the
proper
setting
of
the
needle
bar
on
Style
61400A
using
extra
short
needles
Types
183GNS
or
183GPS.
The
setting
of
the
needle
bar
on
Style
61400 B
using
short
needles
Types
180GNS
or
180GPS
is
accomplished
in
the
same
manner
except
that
the
lower
pair
of
timing
marks
on
the
needle
bar
is
used.
TIMING THE
HOOK
Tip the machine back
so
that
it
rests
on the
rest
pin
in
the table top.
Insert
a new needle. Loosen the
two
screws
and swing out the bobbin
case
positioning finger
(B, Fig. 14). Loosen the
three
set
screws
(A)
in
the hook
and hold the hook and bobbin
case
holder in such a position
as
to
prevent
interference
with the needle.
Tum
the hand-
wheel
in
operating direction until the needle
bar
is
at
its
lowest position, continue to
turn
the handwheel until the
needle
is
ascending and the lowest timing
mark
of the
pair
used
{C,
Fig.
13)
in
setting the needle
bar
is
even with the
lower edge of the needle
bar
bushing (B).
Turn
the hook on the shaft until the point of the hook
is
even with the
center
of the needle and
as
close to the
needle
as
possible without deflecting
it.
A spacing of .003
to .005 inch between
the needle and the
point of the hook
Fig.
14
is
satisfactory.
With the hook in
this
position,
tighten the
set
screw
opposite the hook point
securely.
Then tighten two remaining
screws
securely
and
recheck
the timing of hook with the needle
at
which time the top
of the eye of the needle should be about
1/64
inch below
the bottom of the hook point.
If
this
condition does not
exist,
recheck
the setting of the needle
bar
bushing in
re-
lation
to
the
throat
plate seat.
Adjust the bobbin
case
holder
positioning finger by
turning the bobbin
case
holder until the finger
recess
is
at
the top..
Place
the projection on the finger into the
bobbin
case
holder
recess
and tighten the finger
attach-
ing
screws
securely,
allowing 1/32 inch
clearance
between
the outside edge of projection and inside edge of bobbin
case
recess
(Fig. 15).
-17-
Fig.
15
From the library of: Superior Sewing Machine & Supply LLC