EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Unit
  6. •
  7. Measuring Instrument
  8. •
  9. Unit UT-213C User manual

Unit UT-213C User manual

Other Unit Measuring Instrument manuals

Unit UT-P41 User manual

Unit

Unit UT-P41 User manual

Unit UTE310 User manual

Unit

Unit UTE310 User manual

Unit UT381 User manual

Unit

Unit UT381 User manual

Unit UT602 User manual

Unit

Unit UT602 User manual

Unit UTS1000 Series User manual

Unit

Unit UTS1000 Series User manual

Unit UT371 User manual

Unit

Unit UT371 User manual

Unit UT-P32 User manual

Unit

Unit UT-P32 User manual

Unit UT90A User manual

Unit

Unit UT90A User manual

Unit UT381 User manual

Unit

Unit UT381 User manual

Unit UTL8200+ Series User manual

Unit

Unit UTL8200+ Series User manual

Unit UT241 User manual

Unit

Unit UT241 User manual

Unit UT585 User manual

Unit

Unit UT585 User manual

Unit UT385 User manual

Unit

Unit UT385 User manual

Unit UT685B User manual

Unit

Unit UT685B User manual

Unit MIE0149 User manual

Unit

Unit MIE0149 User manual

Unit UT-P40 User manual

Unit

Unit UT-P40 User manual

Unit UT330+ Series User manual

Unit

Unit UT330+ Series User manual

Unit UTS3000B/A Series User manual

Unit

Unit UTS3000B/A Series User manual

Unit UT372 User manual

Unit

Unit UT372 User manual

Unit UTL8500X Series User manual

Unit

Unit UTL8500X Series User manual

Unit UT312 User manual

Unit

Unit UT312 User manual

Unit UT118A User manual

Unit

Unit UT118A User manual

Unit UT-P31 User manual

Unit

Unit UT-P31 User manual

Unit UTR2810E Series User manual

Unit

Unit UTR2810E Series User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 1/6
Warning!
Please read the user manual included in this work as it contains important information related with safety of installation and use of
the device.
Only persons who read the user manual may use the device.
The user manual must be kept because it may be required in the future. The device is to be used exclusively for purposes specified
in this user manual.
The device must be unpacked prior to starting-up. After removing the packaging make sure the device is in working order.
If the product has defects, it should not be used until it is repaired.
The product is intended for use at home and commercial use and may not be used for other than intended use.
The manufacturer is not liable for damages resulting from not adhering to the rules contained in the user manual, therefore, we
recommend to follow the aforementioned safety rules for operation and maintenance of the device. In this way you will ensure
yourself safety and avoid causing damage to the device.
The manufacturer and the supplier are not liable for losses or damages arising out of the product, including financial or intangible
losses, loss of profits, income, data, pleasure from use of the product or other products related with it - indirect, incidental or
consequential loss or damage. The above provisions apply whether the loss or damage concerns:
1. Deterioration of quality or the lack of operation of the products or products related with it due to damage as well as the lack of
access to the product when it is undergoing repair, which results in stoppage the loss of user's time or a break in business activity;
2. Improper results of operation of the product or products related with it;
3. It applies to losses and damages according to any legal category, including negligence and other losses, termination of a
contract, expressed or implied guarantee and strict liability (even if the manufacturer or the supplier was notified about the
possibility of occurrence of such damages).
Safety measures:
Particular attention at designing was directed to quality standards of the device where ensuring safety of operation is the most
important factor.
The device must be secured against contact with caustic, staining and viscous fluids.
The device was designed in such a way that it restarts operation when power supply is restored after a break.
Turn off the device before transporting it.
Prior to connecting the device to a power source check whether the supplied voltage is consistent with rated voltage specified in
the user manual.
Attention! We recommend using protections to further protect the device from possible overvoltages in installations.
Surge protectors are effective protection against accidental pass to the device voltages higher than the rated. Damages
caused by pass the voltages higher than specified in manual, are not under warranty.
Proper product disposal:
A marking of a crossed out waste bin indicates that the product may not be disposed together with other household waste in the
entire EU. To avoid possible damage to the natural environment of health due to uncontrolled waste disposal, therefore, it should be
handed over for recycling, propagating in this way sustainable use of natural resources.
To return a worn-out product, use a collection and disposal system of this type of equipment or contact a seller from whom it was
purchased. He will then be recycled in an environmentally-friendly way.
It is forbidden to use the device in case its power cord or plug is damaged, the device works incorrectly, was damaged or dropped.
A damaged power cord or plug must be replaced with new ones by the manufacturer, personnel of service centre or a person with
relevant qualifications in order to avoid the risk of electric shock. We do not recommend repairing the device on one's own for
safety reasons.
The device is not intended for operation by persons (including children) with limited physical, sensory or mental capabilities as well
as persons inexperienced in operation or not competent to operate of such device, unless the operation is supervised by a person
responsible for their safety or in line with instructions for use provided by such person.
It is forbidden to touch the plug with wet hands! Pull the plug, never the cable, to pull out the plug from a socket.
The device is to be used exclusively according to its use described in this manual. Use of accessories not recommended by the
manufacturer of the device may cause fire, electric shock or injuries.
Marking of a lightning inside a equilateral triangle signifies presence of dangerous voltage, contained under the cover of the device.
It may be dangerous for user's life and health.
User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 2/6
The UT-213C is a universal digital meter equipped with
clamps enabling the measurement of high currents.
The device measures: voltage, current, frequency,
resistance, capacity and temperature. In addition, the
meter has an electric field detection function (NCV).
The meter is equipped with the True RMS transducer
enabling accurate measurement of the RMS current
and voltage for both sinusoidal and distorted
waveforms.
DC voltage measurement:
400 mV ± (1% + 8) @ 0.1 mV ,
4 V ± (0.8% + 1) @ 0.001 V ,
40 V ± (0.8% + 3) @ 0.01 V ,
400 V ± (0.8% + 3) @ 0.1 V ,
600 V ± (1% + 3) @ 1 V
AC voltage measurement:
4 V ± (1.2% + 5) @ 0.001 V ,
40 V ± (1.2% + 5) @ 0.01 V ,
400 V ± (1.2% + 5) @ 0.1 V ,
600 V ± (1.5% + 5) @ 1 V
DC current measurement: 40 A ± (2% + 3) @ 0.01 A ,
400 A ± (2% + 3) @ 0.1 A
AC current measurement: 40 A ± (2.5% + 5) @ 0.01 A ,
400 A ± (2.5% + 5) @ 0.1 A
Resistance measurement:
400 Ω ± (1.2% + 2) @ 0.1 Ω ,
4 kΩ ± (1% + 2) @ 0.001 kΩ ,
40 kΩ ± (1% + 2) @ 0.01 kΩ ,
400 kΩ ± (1% + 2) @ 0.1 kΩ ,
4 MΩ ± (1.2% + 3) @ 0.001 MΩ ,
40 MΩ ± (2% + 5) @ 0.01 MΩ
Capacitance measurement:
40 nF ± (4% + 25) @ 0.01 nF ,
400 nF ± (4% + 5) @ 0.1 nF ,
4 µF ± (4% + 5) @ 0.001 µF ,
40 µF ± (4% + 5) @ 0.01 µF ,
400 µF ± (4% + 5) @ 0.1 µF ,
4 mF ± (10%) @ 0.001 mF
40 mF @ 0.01 mF
Inductance measurement:
Frequency measurement: 10 Hz ... 1 MHz ± (0.1% + 4) @ 0.01 Hz ... 1 kHz ± (0.1% + 4)
User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 3/6
Temperature measurement:
• °C
-40 ... 40 °C ± (3% + 5) @ 1 °C
40 ... 400 °C ± (3% + 5) @ 1 °C
400 ... 1000 °C ± (1% + 3) @ 1 °C,
• °F
-40 ... 104 °F ± (3% + 10) @ 1 °F
104 ... 752 °F ± (3% + 10) @ 1 °F
752 ... 1832 °F ± (2% + 10) @ 0.1 °F
Automatic change of measuring ranges:
Diode test:
Sound signal of the continuity test:
RS-232:
USB:
Main features:
• True RMS - accurate measurement of the RMS current and voltage for any
waveform,
• NCV - electric field detection function,
• REL - relative measurement mode,
• Writing the value MAX / MIN,
• Hold - stopping the meter reading,
• Flashlight built-in,
• Large, readable LCD display with backlight,
• Low battery level alarm,
• Aesthetic and solid construction,
• The set includes a practical case
Power supply: 3 x 1.5V, type AAA/LR03 battery - included
Weight: 0.24 kg
Dimensions: 221 x 71 x 41 mm
Manufacturer / Brand: UNI-T
Guarantee: 2 years
User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 4/6
Front panel:
Connectors:
User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 5/6
Side view:
Place for batteries 3 x 1.5V AAA:
In the kit:
User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04 UT-213C 6/6
Device is secured by handy case: