manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Unit
  6. •
  7. Measuring Instrument
  8. •
  9. Unit UT353 User manual

Unit UT353 User manual

Other Unit Measuring Instrument manuals

Unit UTE9806+ User manual

Unit

Unit UTE9806+ User manual

Unit UT253A User manual

Unit

Unit UT253A User manual

Unit UTE310 User manual

Unit

Unit UTE310 User manual

Unit UT381 User manual

Unit

Unit UT381 User manual

Unit MIE0149 User manual

Unit

Unit MIE0149 User manual

Unit UT203+ User manual

Unit

Unit UT203+ User manual

Unit UTE9802+ User manual

Unit

Unit UTE9802+ User manual

Unit UT201+ User manual

Unit

Unit UT201+ User manual

Unit UT372 User manual

Unit

Unit UT372 User manual

Unit UT-P33 User manual

Unit

Unit UT-P33 User manual

Unit UT381 User manual

Unit

Unit UT381 User manual

Unit A37 Operating manual

Unit

Unit A37 Operating manual

Unit UTL8500 Series User manual

Unit

Unit UTL8500 Series User manual

Unit UT-213C User manual

Unit

Unit UT-213C User manual

Unit UT585 User manual

Unit

Unit UT585 User manual

Unit UT256A User manual

Unit

Unit UT256A User manual

Unit UTD4000 Series User manual

Unit

Unit UTD4000 Series User manual

Unit UT268B User manual

Unit

Unit UT268B User manual

Unit UTS1000 Series User manual

Unit

Unit UTS1000 Series User manual

Unit UT372D User manual

Unit

Unit UT372D User manual

Unit UT267B User manual

Unit

Unit UT267B User manual

Unit LM50A User manual

Unit

Unit LM50A User manual

Unit UT-P32 User manual

Unit

Unit UT-P32 User manual

Unit UT-P40 User manual

Unit

Unit UT-P40 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PIN:
110401107881 X
UT353
Mini Sound Meters
Operating Instruction
1.1ntroduction
UT353
is
a stable, safe, reliable mini sound meter, widely
used
in
noise detection, quality control, health control,
environmental noise measurement
in
factory, traffic, home
audio and other places.
This operating manual includes relevant safety information
and warnings. Please read this manual carefully and
observe all cautions.
.&.
Warning:
Before using the product, please read the operation rules
carefully.
2.0ut
of
the Box
Open the packing box and take out the meter.
Please check carefylly if any items are missing or
damaged.
1Wind-proof ball---------------1
2.
Operating manual-----------1
3.0peration
Safety
This product strictly follows the requirements
of
"General
specification
for
sound
level
meters"
in
design
and
production.
1.Please check the
meter
and the accessories before
using
and
beware
of
any
damage
or
abnormal
phenomenon. If you find the case is damaged or the
LCD
shows nothing, or
you
consider that the meter could
not work properly anymore, please stop using
it.
2.0bserve the operating instructions while measuring.
3.00
not open the meter at will or change internal wiring
to
avoid damages to the mater.
4When
the
LCD
displays "COil", replace the battery timely.
Remove the battery if the meter is not used for a long
time.
5.00
not store or use the meter
in
high temperature, high
humidity,
flammable.
combustible
or
strong
electromagnetic
environment.
6.Please use soft cloth and neutral detergent
to
clean the
case for maintenance. Do not use grinding agent and
solvent
to
avoid
case
corrosion
and
damage to the
meter.
4.Product Outlook
1 Wind-proof ball I 2 I Microphone
3 Meter case I 4 I LCD display
5 Function keys
UNI-T.
Wind
(}1
~i)
Figure 1
5.
Display Interface
CD
®
HOLD
111111'1
®
J.O.O.O::
®
®
®
FAST
SLOW
(j)
Figure 2
1 Maximum measurement 5 A weighted
2 Minimum measurement 6 C weighted
3 Data hold 7 Slow response rate
4 Low battery 8 Fast response rate
9 Measurement value
6.
Key Function and Setup
1.
ON/OFF:
Short press once
to
start
up;
short press again
to
power
off.
Note: Product's auto power off feature can
be
disabled:
Press and
hold
"HOLD" and
then
piess "ON/OFF" key
to
enable/disable auto power
off,
LCD
will
display "APO OFF'
to
indicate status.
2.
FAST/SLOW:
Sampling time: When measuring, pressing this key
to
select between fast time of 125ms and slow time of 1
s.
3.
MAX/MIN:
Pressing this key to select maximum, minimum and
normal value measurement; when maximum or minimum
measurement
is
selected, the meter always shows the
maximum reading or the minimum reading.
4. HOLD/BL:
HOLD:
Short
press
this
key
once
to
hold
the
measurement: short press the key once again to exit
data hold and continue normal measurement.
BL:
long press this key
to
turn on backlight, and long
press it again to turn off backlight.
7.
Technical Specifications
1.
Noise (dB)
Function Range Resolution Accuracy Description
Sound Level
30~130dB
0.1
dB
±1.5
dB Rate response: 31.5Hz-BKHz
Sampling Time
FAST
125ms
SLOW
1000ms
Overload Indication Shows
"UN"
and "OL"
MAXIMIN Measurement Shows "MAXIMIN"
Data Holdl Backlight Shows "HOLD" and turns backlight on or off
Auto Power Off Automatically power off after 5mins without operation.
Low Battery Indication
3,0~3.5V
Shows low battery prompt when power is
3.0-3.5V
2.
General Type:
a.
LCD display: 4-bit LCD display. The maximum display
is
9999.
b.
Overload indication: The meter shows "UN" when
under range, and shows "OL" when
over
range.
c.
Low battery indication: prompt
"a",
The new battery
should
be
replaced
in
time.
d,
Sampling rate: fast rate 1/125ms, slow rate
111
s
e.
Sensor type:
1/2
inch condenser microphone
f.
Impact strength: Can withstand the impact of landing
from 1 meter height
g.
Power requirement: 1.5V batteries
(MA)
x3
h. Product size: 150mmx52mmx27mm
I.
Weight: 116g
3.
Environment
Specification
a.
Indoor use
b.
Altitude height: 2000m
c.
Safety: EN61326-1
d.
Pollution level: 2
e.
Working temperature and humidity:
Oo(
-30
0( (not greater than 80%RH)
300
(-400(
(not greater than
BO%RH)
40"(-50"(
(not greater than 45%RH)
f:
Storage temperature and humidity:
_200(_600( (not greater than
BO%RH)
4.
Electrical
Specifications
a.
Accuracy: ±1.5dB (@1kHz Standard audio source).
Calibration period is 1 year.
b.
Environment temperature:
23°(
±
5°(
c.
Environment humidity:
:So:BO%RH
d.
Temperature coefficient:
0.1
x
(Accuracy)/'(
5.
General Maintenance
Warning: please do not open the meter case
to
avoid
affecting device accuracy or damage to the meter.
a.
Maintenance and service of the meter should
be
accomplished
by
professional personnel or designated
maintenance department.
b.
Clean the case by dry cloth periodically. Detergent
with abrasive or solvent composition
shall
not
be
used.
6.
Battery Installation and Replacement
a,
This device uses 3 pieces
of
AAA 1.5V batteries.
Please
see
figure below for steps of battery installation
and replacement.
b,
Turn the panel down, push the battery
cover
open
in
the
direction of the arrow, lift the cover and remove
the batteries; install new batteries
in
accordance of
polarity indications.
c.
Please use batteries of same type instead of improper
ones.
d.
Close the cover tightly after installing new batteries.
Figure 3
UNI-"T:
UNI-TFIENO
TECHNOLOGY,
CHINA>
CO.,
LTO.
No6. Gong
Ye
Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, China
Tel:
(86-769) 8572 3888
http://wvlW.uni-trend.com