UPONOR REMOTE ACCESS MODULE R-56 - MANUAL
4
UK
UPONOR REMOTE ACCESS MODULE R-56 - MANUAL 5
UK
Technical characteristics
Electrical protection ReceiverClassII-IP30
Power supply 230VAC+10/-15%,50Hz
Connection 8 points screw connector on the bottom of
the receiver
•1relayfreecontactforremotecontrol
•2Inputsforexternalsystem
•1freecontactforexternalsensor
Operating and
storage conditions
•operatingtemperaturerange:0°Cto+50°C
•operatinghumidityrange:0%RHto70%RH
•storagetemperaturerange:-20°Cto+65°C
•storagehumidityrange:0%RHto80%RH
Certifications CE.EN300220-3,EN301489
(Radio Frequency certifications)
SMS Setup
Check the SMS function by
sendingthistextbySMStothe
remote access module R-56:
PASS CONF
Note! You must use capital
letters in all messages to the
remote access module R-56.
You will receive a reply with all
the default parameter values of
your installation:
Data Command description
Default
settings
Ssss Sets new password (case sensitive!)
Always four characters PASS
ON-OFF Controls if the remote access module R-56 shall
confirm command or not ON
ON-OFF IfON,anSMSissentwhenaneventoccurs ON
ON-OFF IfON,anSMSissentwhenaneventoccurs ON
NDefines alarm limit for the house low temperature
alarm.0willdeactivatethealarm 5
N
0->ControlledonlybySMS
1 -> On if ALARM1 is ON
2 -> On if ALARM2 is ON
3->OnifALARM1orALARM2ison
4 -> On if Alarm Temp is on
3
NNot used on remote access module R-56 3
N
Sets how often the remote access module R-56
shall send status to receiving mobile-phone, if you
set0theheartbeatwillshutoff.Maxnumberof
hoursare9999hours(416days)
0(NO)
NNumber of SMS sent. 0
N (Max 14)
Sets which phone the remote access module R-56
shall send message to when alarm occurs. Must be
set up at the installation of the system.
Note! The phone number must include the country
code number
-
CODE=PASS
REPLY=ON
ALARM1=ON
ALARM2=ON
ALARMTEMP=5
OUTPUT=3
BUZZER=3
HEARTBEAT=0
SMSCOUNTER=0
PHONE=+33600000000