CALL MODULES
PROGRAMMING
THEN DEFAULT "1"). THIS NUMBER WILL REFLECT ON THE
LED DISPLAY DURING THE CALL. IT CAN BE NUMBER OF
YOUR YARD OBJECT (THE SCOPE 1-255). REMEMBER TO
SET THE SAME PHYSICAL ADDRESS In DOORPHONE USING
JUMPERS (DEFAULT ADRESS IS "1").
3.07 SETTING EI2 AS A DIRECT CALL
In this step we can assign to EI2 input a function of a direct call of
specified doorphone. This can be useful if, beside numeric
keyboard, we need to install keyboard with function buttons. After
setting doorphone’s address (1-255 range) and connecting EI2
input with GND then doorphone with specified address will be
called.
In this step we can set electrical lock work mode. The options are:
0 Disabled (it is controlled with steps 3.05, 3.10 and 3.11
settings),
1-255 Direct call (this number mean physical address).
Press and hold # button to save value.
Default setting - 0
3.08 SETTING EI3 AS A DIRECT CALL
In this step we can assign to EI3 input a function of a direct call of
specified doorphone. This can be useful if, beside numeric
keyboard, we need to install keyboard with function buttons. After
setting doorphone’s address (1-255 range) and connecting EI3
input with GND then doorphone with specified address will be
called.
In this step we can set electrical lock work mode. The options are:
0 Disabled (it is controlled with steps 3.05, 3.10 and 3.11
settings),
1-255 Direct call (this number mean physical address).
Press and hold # button to save value.
Default setting - 0
3.09 SETTING EI4 AS A DIRECT CALL
In this step we can assign to EI4 input a function of a direct call of
specified doorphone. This can be useful if, beside numeric
keyboard, we need to install keyboard with function buttons. After
setting doorphones address (1-255 range) and connecting EI4 input
with GND then doorphone with specified address will be called.
In this step we can set electrical lock work mode. The options are:
0 Disabled (it is controlled with steps 3.05, 3.10 and 3.11
settings),
1-255 Direct call (this number mean physical address).
Press and hold # button to save value.
Default setting - 0
3.10 OC1 SETTINGS
In this step we can set OC1 output release in dependence on event.
On the OC1 output appear GND potential after event occurs or after
specified event duration.
The options are (in dependence on parameter value):
0 OC1 is disabled,
1 Time activation / releasing impulse after pressing T1 button in
handset (180R)
2 OC1 activated automatically (during conversation),
4 OC1 activated after entering individual opening code preceded
with double press of #button,
8 OC1 activated after entering individual opening code preceded
with single press of #button, Dallas key or DOOR button (on
handset),
16 Activation with EI4 input (after connecting EI4 with GND),
32 Activation with EI3 input (after connecting EI3 with GND),
64 Activation with EI2 input (after connecting EI2 with GND),
128 Activation with EI1 input (after connecting EI1 with GND),
NOTE: If we need that OC1 output was released by several
events then parameters should be added together, for example
after connecting EI1 with GND and entering individual opening
codes. We should add values for these events (8+128=136) and
enter this value in this step.
Press and hold # button to save value.
Default setting - 0
WARNING ! - IN THIS POSITION OF PROGRAMMING CHANGE
FOR VALUE "5" IF YOU HAVE PURCHASED TO INTECOM SET
RELAY REF. NO. 788/52 TO CONTROL EX. ENTRANCE GATE
USING ADDITIONAL BUTTON IN DOORPHONE.
3.11 OC2 SETTINGS
In this step we can set OC1 output release in dependence on event.
On the OC2 output appear GND potential after event occurs or after
specified event duration.
The options are (in dependence on parameter value):
0 OC2 is disabled,
1 Time activation / releasing impulse after pressing T1 button in
handset (180R)
2 OC2 activated automatically (during conversation),
4 OC2 activated after entering individual opening code preceded
with double press of #button,
8 OC2 activated after entering individual opening code preceded
with single press of #button, Dallas key or DOOR button (on
handset),
16 Activation with EI4 input (after connecting EI4 with GND),
32 Activation with EI3 input (after connecting EI3 with GND),
64 Activation with EI2 input (after connecting EI2 with GND),
128 Activation with EI1 input (after connecting EI1 with GND).
NOTE: If we need that OC2 output was released by several
events then parameters should be added together, for example
after connecting EI1 with GND and entering individual opening
codes. We should add values for these events (8+128=136) and
enter this value in this step.
Press and hold # button to save value.
Default setting - 0
3.12 PS GENERATOR SETTINGS