1. INSTALLATION
NOTE: Mounting brackets should be installed to a rigid object to
prevent movement which could affect alignment and cause failures.
IMPORTANT: Conduit should be used from the control box to the
photo eye wiring box to protect wires from damage and moisture.
The wiring box has ½ inch knockouts located on the back and
bottom for the conduit connection. Do not remove the
TX-Transmitter wiring box knockout if using battery option.
1. Determine the best location for the photo eyes considering the
correct distance from the ground, conduit for wiring, location
of any irrigation system that might exist (avoid water spray) and
mounting surfaces are aligned with one another.
2. Install the mounting brackets and verify they are aligned with
each other. See figure 1.
3. Install the Transmitter and Receiver wiring box to the mounting
brackets using 4 screws and nuts.
4. Install the conduit to the receiver wiring box. If hardwired
installation install conduit for transmitter wiring box.
5. Install the receiver wires into the wiring box. If hardwired
installation install transmitter wires into the wiring box.
6. Route wire through the photo eye back plate.
7. Install the Transmitter and Receiver photo eye back plate to the
wiring box using the 4 sheet metal screws.
8. Connect wires per the wiring instructions.
9. Do not install covers at this time, this will be done after alignment
is complete.
PHOTO EYE
Infrared Through Beam Part
#550011
INSTALLATION MANUAL
TECHNICAL SPECIFICATIONS
Power supply TX: 3.6V
Battery voltage 2 x 3.6V
Battery capacity 2.4Ah
Battery type ER14505
Expected battery life 15 months
Power supply RX 9 / 24 Vac/dc
Current consumption Transmitter 400 μA
Current consumption Receiver 20 mA
Double contact relay with serial exchange yes
RX output contacts 1 NO / 1 NC
Max DC power on relay contacts 24W / 48V
Max AC power on relay contacts 60 VA / 48 V
Operating temperature -4°F /+131°F
Housing protection IP55
Rated range 42 ft / 13 m
Dimensions with hood: WxHxD 75 x 105 x 105 mm
2.95 x 4.13 x 4.13 in
PACKING LIST
ITEM Qty
TX / TRANSMITTER 1
RX / RECEIVER 1
WIRING BOX 2
HOOD 2
MOUNTING BRACKETS 2
RUBBER SEAL 2
WIRING BOX MOUNTING SCREWS 8
#8 – 18 x ¾ inch Self tapping sheet metal (20mm length)
TX / RX MOUNTING SCREWS 8
#4 – 18 x ½ inch sheet metal (12.7mm length)
COVER MOUNTING SCREWS 4
#4 – ¼ inch black sheet metal (6.5mm length)
BATTERY 3.6v LITHIUM 2
Read all instructions before installing this product.
Monitoring Method: N/C Contact
The infrared photo eyes are a People and Property safety device
intended for use with automatic gate operating systems. Swing gate
operators require at least one external monitored entrapment device
for gate operation and Slide gate operators require at least two
external monitored entrapment devices (one for each direction) for
gate operation per UL325 the standard for gate operator safety.
See gate operator installation manual.
The transmitter can be powered by two 3.6 vdc lithium batteries
(model - ER14505) or it may be hard-wired to the gate operator
control board. The expected battery life should exceed 1 year.
Rated range up to 42 feet / 13 meters in most conditions.
Fig. 1 Mounting Surface Alignment
Fig. 2
www.USAutomaticGateOpeners.com | (800) 878-7829 | [email protected]

2. ELECTRICAL CONNECTIONS
Wire size recommended 20 gauge stranded copper
NOTE: Identify the type of installation the photo eye is being used for.
A. Monitored Entrapment Device per UL325
B. Vehicular Safety Device
A. Wiring for Monitored Entrapment Device
installation Receiver
1. Photo eye “12” vdc connects to the Photo Eye power connection
on the gate operator control board.
2. Photo eye “0” ground connects to the common ground
connection on the gate operator control board.
3. Photo eye “C” common connects to the common ground
connection on the gate operator control board.
4. Photo eye “NC” normally closed connects to the control board
input for the direction of travel you are protecting.
Transmitter
NOTE: No wiring is required if the battery power option is being used, if
hard wired installation is being used wire as below.
1. Photo eye 12 vdc connects to the Photo Eye power connection
on the gate operator control board. See figure 3.
2. Photo Eye ground wires to the common ground connection on
the gate operator control board. See figure 3.
B. Wiring for Vehicular safety Device Installation Receiver
1. Photo eye “12” vdc connects to the Photo Eye power connection
on the gate operator control board.
2. Photo eye “0” ground connects to the common ground
connection on the gate operator control board.
3. Photo eye “C” common connects to the common ground
connection on the gate operator control board.
4. Photo eye “NO” normally open connects to the control board
“Safety Loop/Reversing Edge input”
Transmitter
NOTE: No wiring is required if the battery power option is being used,
if hard wired installation is being used wire as below.
1. Photo eye 12 vdc connects to the Photo Eye power connection
on the gate operator control board. See figure 3.
2. Photo Eye ground wires to the common ground connection on
the gate operator control board. See figure 3.
WARRANTY
USAutomatic, LLC warrants this product to be free of defects in
materials and workmanship for 1 YEAR. For a period of 1
YEAR following purchase USAutomatic, LLC. will repair or
replace the product free of charge, including parts, shop labor
and return to customer shipping and handling. This 1 YEAR
warranty does not cover the plastic case from normal wear or
damage due to misuse.
To have the product sent for warranty consideration, it must be
returned with the proof of purchase and a return authorization
number. To obtain a return authorization number please call
(800) 878-7829 for assistance. The return authorization number
must be clearly marked on the outside of the return package or
it may not be accepted.
USAutomatic LLC
3. ALIGNMENT
The RX / Receiver has a red LED which will illuminate when
power is applied to the RX / Receiver. When aligned with the
TX / Transmitter, the red LED will go OFF and the green LED
will come ON. When beam is broken, the red LED will come
ON and the green LED will go OFF.
A feature to assist in the
optimal alignment allows
for a voltmeter to be
connected to the TP- and
TP+ test points located on
the RX / Receiver. With
voltmeter attached use
alignment chart verify the
optimal alignment.
Alignment Chart
TP-/TP+ readings
DCV Signal Strength Red LED Grn LED
0 Vdc No Signal ON OFF
3 Vdc Minimum useful signal OFF ON
5 Vdc Maximum useful signal OFF ON
Once alignment is complete, install the covers using the 4 black
screws. Install the hood onto each unit.
4. BATTERY INFORMATION
TX / Transmitter battery Requirement - Two 3.6 vdc lithium
batteries (model - ER14505) or equivalent. When installing
verify the correct polarity shown in figure 3.
NOTE: Please dispose of the batteries properly as they are
hazardous waste.
ELECTRICAL CONNECTIONS
Fig. 3
Fig. 4
www.USAutomaticGateOpeners.com | (800) 878-7829 | [email protected]
Other manuals for PHOTO EYE
1
This manual suits for next models
1
Other US Automatic IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

BQT Solutions
BQT Solutions miPASS BT825 installation guide

Grosvenor
Grosvenor Janus C4 485 installation guide

ACT
ACT ACTsmart2 Series Operating and installation instructions

BSW SECURITY
BSW SECURITY RH50-N400-WMG Series Mounting and Connection Instructions

Roger
Roger PR302 installation guide

Dahua
Dahua VTO2101E-P quick start guide