1. USING THIS MANUAL – GENERAL
This manual (hereinaer referred to as the “Manual”) is intended to be used as work of
reference for professional, well trained and authorised users to be able to safely install and
use the product menoned on the cover of this document (hereinaer referred to as the
“Product”). The observaon of the Manual does not dispense the user from the obser-
vance of the local safety instrucons and regulaons other than provided by the Manual.
Such safety instrucons and regulaons must be observed at all me.
For informaon about specic adjustments, maintenance or repair jobs which are not dealt
with in this manual, please contact your Product supplier or UV Medico A/S.
If you suspect that the Product is damaged or detect a potenal or actual danger when
using the Product, immediately disconnue use of the Product and contact your supplier of
the Product.
Contents
1. USING THIS MANUAL – GENERAL 3
1.1 BASIC SAFETY INSTRUCTIONS 4
2. DISCLAIMERS 5
3. SAFETY INSTRUCTIONS AND WARNINGS 5
3.1. User manual 5
3.2. Intended use and installaon 5
3.3. Safety features of the Product 5
3.4. Modicaon 6
4. GENERAL CHARACTERISTICS AND TECHNICAL SPECIFICATIONS 6
5. CONSTRUCTION 7
6. INSTALLATION OF THE PRODUCT 8
6.1. Choose the appropriate locaon 8
6.2. Unboxing and inspecon 8
6.3. UV222 xture installaon 9
6.4. Wiring the Product to power source 10
6.5. Understanding the unit’s operaon: 11
6.6. Seng up the UV222 11
6.7. Understanding the funcon of the signal LED 20
6.8. Replacements 20
7. PRODUCT FAILURE 21
8. CLEANING AND MAINTENANCE 21
9. LIGHT SOURCE REPLACEMENT 22
10. REPAIRS 22
Warranty 22
NOTES: 23

UV222 Technical & Installation Manual4
1.1. BASIC SAFETY INSTRUCTIONS
To minimise the risk of injury, the following basic safety precauons should be observed
with each use of the Product:
Do not remove the scker on the front of the unit unl the UV222 is commissioned by a
qualied installer.
Do not put any object in close front of the surface of the UV222.
Do not put plasc or glass in front of the UV222. It does not transmit UV.
Make sure the UV222 has an unobstructed path towards the area to be disinfected.
Do not use ammable substances near the lamp module.
Do not use ammable or combusble gases or liquids, such as oxygen, hydrogen, or chemi-
cals, near a lamp module. Failure to obey may result in re or explosion.
If Front glass is broken, disconnect UV222 immediately and and contact an authorised
installer.
Do not turn on any UV222 with a broken front glass.
Do not disassemble or modify the lamp module.
Disassembly or modicaon may result in re, electric shock, or injury.
Turn o the electrical power during lamp module maintenance.
Do not remove any safety labelling or parts.
Do not touch the lamp module during operaon.
Otherwise, it may result in re, electric shock, or injury.
Ground the device or metal parts of the housing that are close to the lamp module.
Otherwise, it may result in re, electric shock, or injury.
For those with photosensivity, take measures similar to those for daily sunlight ultravi-
olet rays.
Due to the absorpon characteriscs of ultraviolet rays in the skin, it is considered that
the eect of 222nm light sensivity on people exposed to ultraviolet rays will be less than
when exposed to sunlight. For those with photosensivity, take measures similar to those
for daily sunlight ultraviolet rays, such as long sleeves and hats.
Do not use the unit for purposes other than disinfecon.
The unit is designed for disinfecon. Using it for any other purpose may result in unexpect-
ed accidents.

5
2. DISCLAIMERS
UV Medico A/S with registered oce at Søren Frichs Vej 40E, 8230 Åbyhøj - Denmark, or
any of its aliates, does not accept any liability for material damage, including damage to
the Product or personal injury caused by non-observance by the user of the safety instruc-
ons in the Manual or the applicable laws. As such UV Medico A/S shall among others not
be liable for any damage or injury if the Product is used contrary to or for purposes other
than its intended use, is installed, used, maintained or repaired negligently or contrary to
the instrucons menoned in the Manual or on the Product; also in the case the Product is
modied, and when safety devices and features are disregarded or overridden.
3. SAFETY INSTRUCTIONS AND WARNINGS
3.1. User manual
Every person using the Product must read and understand the contents of the Manual
and familiarise themselves with it before any use of the Product, and must strictly observe
the instrucons set out herein. If you are an employee or are acng on behalf of another
person, your employer/that person must instruct you in accordance with the Manual and
ensure that all instrucons set out herein are complied with.
Do not use the Product if that is not the case.
3.2. Intended use and installaon
The Product is intended exclusively for air and surface disinfecon. Using the Product for
other purposes is contrary to its intended use and is done at own risk.
To ensure safe use of the Product, its installaon, including all its safety features and
devices, and its maintenance and repair must be carried out correctly by a qualied
installer. All of the Product safety features and devices must be mounted and may not be
removed but for the purpose of maintenance and repair.
The Product is not intended to be used by minors. Any use of the Product by minors,
regardless of whether or not under the supervision of an adult, is at own risk.
3.3. Safety features of the Product
Each Product is equipped with the following safety features:
• Moon sensor: To detect moon.
• Lidar sensor: To measure distance to the occupancy of the room.
• Mulcolour LED to signal the operaon and state of the unit.

UV222 Technical & Installation Manual6
It is strictly forbidden to override these safety devices or to use the Product if the safety
features are not fully present or disfuncon.
The safety features should be regularly checked for their proper funconing, and if
required, be immediately repaired or replaced.
The pictograms, warnings and instrucons aached to the Product are part of its safety
features. They must not be covered or removed and must be present and legible during the
enre use of the Product.
Immediately replace or repair missing, damaged or illegible pictograms, warnings and
instrucons.
3.4. Modicaon
No modicaon of the product is allowed. All warranty and liability are void if any modica-
ons are done to the UV222.
4. GENERAL CHARACTERISTICS AND TECHNICAL
SPECIFICATIONS
The Product is designed to emit Far UV-C radiaon with a wavelength of 222 nm, in order
to eliminate viruses, bacteria, fungi, and other pathogens, from air and surfaces.
The Far UV-C lamps are designed for 5,000 hours of ecient operaon. Far UV-C lamps
used longer than this, may no longer emit the required level of ultraviolet radiaon to en-
sure the desired germicidal ecacy on harmful microorganisms.
Technical data
Light Source Kr-Cl Excimer lamp
Wavelength 222 nm
UV output power 130 mW (typical)
Input voltage 85-305V AC 50/60HZ
Max power consumpon 17 W
Weight 1.9 KG
Dimensions 303.45 x 120 x 75.25
Power lead 3 x 0.75 mm² -18AWG
Operang temperature 0 to +50°C

7
5. CONSTRUCTION
303.45 mm
120.00 mm
175.00 mm
75.25 mm
85.00 mm

UV222 Technical & Installation Manual8
6. INSTALLATION OF THE PRODUCT
Perform the following steps for the installaon of the Product.
Outside every room where Far UV-C light is used, there must be informaon signs in clear
line of sight.
Installaon must be done according to the local regulaons by a qualied installer.
6.1. Choose the appropriate locaon
Choosing the appropriate locaon is important for the proper funconing and safe use of
the Product.
A dialux simulaon can help you to choose the right posion for disinfecon.
Install the Product in a protected area where the temperature does not fall below 0° C and
the humidity level is low. The Product funcons ideally in a temperature range from 0°C to
+50° C.
Select a Product mounng locaon that is close to surface/area that you want to disinfect.
6.2. Unboxing and inspecon
Read and save all noces, warnings and safety instrucons received with the Product.
Open the box and carefully take the unit out of the box. Take the unit out of the plasc
bag. Do not remove the protecon label on the front of the UV222. The protecon label is
intended to avoid unexpected UV radiaon. Make a visual inspecon of the unit.
Do not power on the unit unl installed by a qualied installer!
CAUTION: Do not touch the glass of the lamp without gloves.
Doing so may result in damage to the lamp. Oil from ngerprints will
permanently etch the glass of the lamp and weaken the structure.

9
6.3. UV222 xture installaon
The unit must be aached to a surface by means of at least 4 mounng pins, preferably
near electrical wires with grounding.
The mounng pins and surface must be strong enough to hold 4 mes the weight of the
unit.
303.45 mm
120.00 mm
175.00 mm
75.25 mm
85.00 mm
Take out the 2x DIN 912 M4 on the boom sides to take o the installaon plate of the
unit.
The installaon plate can be now installed to the surface with 4 mm screws or M4 bolts:

UV222 Technical & Installation Manual10
C
6.4. Wiring the Product to power source
Far UV-C lamps must be operated connuously from a separate, dedicated, 85-305 V
50/60Hz power source.
Standard wiring: Phase / Hot + (brown) (black)
Neutral / Cold – (blue) (white)
Earth (green/yellow) (green)
How to wire the UV222
1) Take of the installaon plate (foot plate)
A
2) Unscrew 3x din965 with T15 screwdriver
B
3) Take o the service plate.
4) Unscrew 2x ph1 (cable blockage)
C
5) Unscrew 2x ph1 (cable connector).
6) Unscrew nut for earth connecon.
7) Rewire the connector correctly.
8) Put cable trough service plate and screw back the cable blockage.
9) Close the backplate with 3x din965.
10) Put the unit back on its installaon plate (foot).
A
B

11
6.5. Understanding the unit’s operaon
The maximum permissible UV-C exposure shall not exceed the ACGIH TLV and NIOSH REL
of 22,0 mJ/cm² for an 8 h day, 40 h work week exposure to UV radiaon at 222 nm.
(UV Medico A/S expects posive changes into the ACGIH that will result in a higher expo-
sure than allowed at this moment. If this changes, UV Medico A/S will update the soware
of the unit to align with the new threshold of exposure).
To achieve the correct radiaon within these limits, following informaon will be pro-
grammed into the UV222 before the start-up of this installaon.
6.6. Seng up the UV222
The installer will need a Microso Windows computer with the UVMEDICO applicaon
installed. Contact your distributor to get access to the latest soware and rmware for the
UV222.
To launch the app, go to the installed folder and open the le:
UV Medico Conguraon App.exe
The app includes two dierent set up modes: simple and advanced.
For the simple mode, follow the instrucons that will appear on the screen.
For the advanced mode, see below:
There is a USB-C connecon
D
on the
side of the unit to connect to a computer
with a USB cable.
Connect your computer to the UV222
unit and it will show up automacally on
the applicaon.
When the app is launched, following
steps needs to be taken:
D

UV222 Technical & Installation Manual12
1) If the UV222 was already installed, you can read out the seng of the unit by pressing
“Get” all sengs will be shown in the applicaon.
A
2) Check if soware version is the latest version. If not, press “Update SW” buon
B
and conrm the pop up by pressing “Yes”.
C
A
B

13
Select the correct soware version
D
and press “Open” to upload the soware.
When nished installing, the soware should be up to date.
D
C

UV222 Technical & Installation Manual14
3) Set the correct hour by pressing “Set Device Time”.
A
The date and hour are now the same as your computer.
4) Dene the ming of the use (duty cycle) of the room where the UV222 is installed:
“On me”: Time from which the room will be occupied by people.
B
“O me”: Time from which the room will not be occupied.
C
B
C
A

15
5) Add the pre and post cleaning cycle.
D
The unit will/can light up before and aer the
duty cycle so you can ensure it when people enter or leave.
6) Add the “Maximum Occupant Time”: how long the room is occupied during the duty
cycle.
E
D
E

UV222 Technical & Installation Manual16
7) Add 3 distances:
a. “Distance to eye height”: Closest distance of the unit to the eye of a human (even
with people walking around).
A
b. “Safety distance”: Closest distance people are allowed to get to the lamp before
it turns itself o. The unit will turn itself back on aer 10 sec. when/if the safety
distance is regained.
B
c. “Primary surface distance”: Distance from the unit to the main surface to
disinfect.
C
All measurements are in cenmetres.
B
C
A

17
8) Change the intensity of the LED signal to the desired output.
D
D
E
9) Save setup into template by pressing “Save Setup”.
E
Name the template. This can be recalled whenever you have similar sengs.

UV222 Technical & Installation Manual18
10) Press “Set” to upload the sengs into the UV222.
A
A
Once this informaon is saved and programmed into the unit, it is ready to test/start up.
The unit will calculate the radiaon automacally to stay within the limits of the ACGIH like
the example below:
If during the duty cycle a person comes closer to the unit than the programmed distance
from the eye, UV222 will automacally stop, and it will resume the acvity 10 sec. aer this
security distance is cleared.
If movement in the room is detected during the pre or post disinfecon cycle, the unit will
stop working, and will resume its acvity aer no more movement is detected.
222 nm Irradiance
Time
Occupied meslot Post
disinfe.
Pre
disinfe.
TLV

19
If the informaon programmed into the UV222 when installed is dierent than the use/
occupancy of the room, UV Medico A/S cannot be held liable for any injuries or misuse of
these units.
If the room changes of use, occupancy or any change that has an inuence on the risks of
exposure, the installer needs to be contacted so the Product is reprogrammed.
11) Tesng the Product.
Right click on the photo of the UV222
B
and a pop up of the test mode will show up.
Here you can quickly light up the UV222 and test the signal LED.
When you press “On”
C
at 222 LightSource secon, it will turn on the UV222 with no
safety! This is only to test the source, (the box “Enable“ will be automacally cked)
When you go to LED Mode you have 3 possibilies to choose:
“Normal Mode” Work as UV222 is programmed.
“Led O” Turns the LED o.
“Led RGBW O” LED test cycle.
When you unck the “Enable” box it goes back to normal conguraon/use.
B
C

UV222 Technical & Installation Manual20
6.7. Understanding the funcon of the signal LED
LED MEANING
No light No power.
Red connuous Error: no feedback from UV222 light source.
Cyan connuous Pre disinfecon / aer disinfecon light source on.
Magenta connuous Light source is on.
Blue connuous In-cycle UV o.
Green connuous Out of cycle.
Flashing red Object to close.
Flashing cyan Pre disinfecon / aer disinfecon per seen movement.
6.8. Replacements
The UV222 has an internal baery and fuse that can be replaced if broken/empty.
Take the unit o the installaon plate and unscrew the 3x din965. Take o the cover and
you will see the fuse (T250V 500mA) and baery (3V CR2032). Replace only with correct
fuse and baery to prevent damage.
Fuse T277V
500mA
Baery 3v
CR2032