manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. V-GREAT
  6. •
  7. Protection Device
  8. •
  9. V-GREAT VG-6653 User manual

V-GREAT VG-6653 User manual

Popular Protection Device manuals by other brands

Merlin Gerin Sepam series 20 Quick start quide

Merlin Gerin

Merlin Gerin Sepam series 20 Quick start quide

OUTSTEEL VENITIAN installation instructions

OUTSTEEL

OUTSTEEL VENITIAN installation instructions

Kemo Electronic M148-24 instructions

Kemo Electronic

Kemo Electronic M148-24 instructions

Endress+Hauser HAW569 quick start guide

Endress+Hauser

Endress+Hauser HAW569 quick start guide

SK ClickClick user manual

SK

SK ClickClick user manual

Ultrasonic SonicPRO installation manual

Ultrasonic

Ultrasonic SonicPRO installation manual

nxt BIA-nXt-DPC 1-22 Installation and operation manual

nxt

nxt BIA-nXt-DPC 1-22 Installation and operation manual

TFortis SG-Switch operating manual

TFortis

TFortis SG-Switch operating manual

BERNINI DESIGN Be172 instruction manual

BERNINI DESIGN

BERNINI DESIGN Be172 instruction manual

Rayleigh Instruments RI-ENERGYSET-3P-ESS-50-100 manual

Rayleigh Instruments

Rayleigh Instruments RI-ENERGYSET-3P-ESS-50-100 manual

E.K.T. ke-DP01 quick start guide

E.K.T.

E.K.T. ke-DP01 quick start guide

Sola HD STV100K Series instruction manual

Sola HD

Sola HD STV100K Series instruction manual

socomec COUNTIS AMd operating instructions

socomec

socomec COUNTIS AMd operating instructions

Siemens SIPROTEC 7SD80 manual

Siemens

Siemens SIPROTEC 7SD80 manual

cias MICRO-RAY installation manual

cias

cias MICRO-RAY installation manual

Sungrow PVS-16MH user manual

Sungrow

Sungrow PVS-16MH user manual

Reer 32010 instruction manual

Reer

Reer 32010 instruction manual

STI STI-7560AC Mounting instructions

STI

STI STI-7560AC Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Issue 1.03
V-GREAT GLOBAL CORPORATION
VG-6653 Conventional Manual Call Point
Installation and Operation Manual V1.03
Features
Alarming by pressing, reset by a special key
Plug-in structure
Designed to comply with EN 54-11
Description
VG-6653 Innovation Manual Call Point (MCP) is
non-addressable. It alarms by the current caused by
pressing the action plate. It can be simply connected to
compatible conventional fire alarm system from various
manufacturers. This MCP is suitable for public places.
When there is fire, pressing the action plate on this MCP
can send alarm signal to compatible conventional fire
alarm control panel.
Installation
The conduit can be surface mounted or flush mounted.
Surface mounting:
First install the back box onto the wall using 4 screws, then
install the base onto the back box. Connect cables to
corresponding terminals as Fig.4. Hook the juts of the MCP
body to the base, and then press the part below the action
plate to combine them completely. Fig. 1 shows surface
mounting.
Flush mounting:
Install the base onto the back box. Then combine the
enclosure and base the same as surface mounting. Fig.
2shows flush mounting.
Fig. 1
Fig. 2
Application
Application of the MCP is shown in Fig. 3 & Fig.4
Output-
Output+
Compatible Fire Alarm
Control Panel
Alarm Zone O-O+I-I+
To the next device
MCP
Fig. 3
Output-
Output+
Compatible Fire Alarm
Control Panel
Alarm Zone O-O+I-I+
4.7k
Ω
E O L
R esistor
D etectors
or D evices
Fig.4
Note:If MCP is at end of detection zoon ,EOL
Resistor:4.7kΩ should be connected across terminals 3.O-
and 4.O+.when connected with V-GREAT Control Panel
series.
Usage of the key
Vertically insert the key into the key-hole, then push it with
force and turn it clockwise. Turn the key back and pull it out
when the action plate is rebounded.
Usage of the test tool
The test tool is used to keep continuity during commissioning
or maintenance when MCP is not installed, so that cable test
can be carried out easily and make the circuit completed.
E
R
T
I
F
I
C
A
T
I
O
N
B
O
A
R
D
L
O
S
S
P
R
E
V
E
N
T
I
O
N
C
L
PCB
19
2831-CPR-F1545 1174d/01
Issue 1.03
V-GREAT GLOBAL CORPORATION
VG-6653 Conventional Manual Call Point
Installation and Operation Manual V1.03
Specification
Operating Voltage
24VDC (12VDC ~28VDC)
Standby Current
≤0.5mA
Alarm Current
≤20mA(equivalent
resistance is 470/1W)
Indicator
Red. Illuminates after
alarming.
Type of Initiating
Part
Reusable
Initiating Mode
Pressing the action plate
manually
Resuming Mode
Manually resumed by a
special key
Wiring
two-wire
Class
Type A, indoor use
Ingress Protection
Rating
IP43
Ambient
Temperature
-10℃~+55℃
Relative Humidity
≤95%, non-condensing
Material of
Enclosure
ABS
Dimensions
(L×W×H)
88mm×88mm×58mm
(with back box)
88mm×88mm×23mm
(without back box)
Mounting Hole
Distance
60mm
Weight
About 160g (with back box)
About 107g (without back
box)
Limited Warranty
V-Great guarantees that the product will be free of charge for
repairing or replacing from defects in design, materials and
workmanship during the warranty period. This warranty
doesn’t cover any product that is found to have been
improperly installed or used in any way not in accordance with
the instructions supplied with the product. Anybody, including
the agents, distributors or employees, is not in the position to
amend the contents of this warranty. Please contact your local
distributor for products not covered by this warranty.
Company: V-GREAT GLOBAL CORPORATION
Add.: Second Floor, Capital City, Independence Avenue,
P.O. Box 1008, Victoria, Mahe, Seychelles
Web:http://www.vgreatglobal.com Email: tech@vgreatglobal.com