GVS T Series User manual

Outdoor Station
T - series Keypad Outdoor Station User Manual_V1.0
T-OS07
User Manual


Contents
Unit 1 Overview.......................................................................................................... 1
1.1 Functions and Characteristics.....................................................................1
1.2 Parameters........................................................................................................ 1
Unit 2 Appearance and Interface........................................................................... 2
2.1 Appearance....................................................................................................... 2
2.2 Dimension..........................................................................................................3
2.3 Interface Introduction..................................................................................... 4
Unit 3 Installation....................................................................................................... 5
3.1 Installation Height........................................................................................... 5
3.2 Installation Steps............................................................................................. 6
3.3 System Wiring.................................................................................................. 7
Unit 4 Operation Instructions................................................................................. 9
4.1 Call By Apartment No..................................................................................... 9
4.2 Call By Name List............................................................................................ 9
4.3 Call Guard Unit...............................................................................................10
4.4 Unlock.............................................................................................................. 10
Unit 5 Settings.......................................................................................................... 11
5.1 Setting Login Interface.................................................................................11
5.2 Main Setting Interface.................................................................................. 12
Unit 6 System Settings...........................................................................................12
6.1 Time Setting.................................................................................................... 13
6.2 Volume Setting............................................................................................... 13
6.3 Language Setting.......................................................................................... 14
6.4 PIN Setting...................................................................................................... 14
6.5 Unlocked-Time Setting.................................................................................15
6.6 Card Management......................................................................................... 15
Unit 7 Configuration Settings...............................................................................17
7.1 Address Setting............................................................................................. 17
7.2 Alarm Setting.................................................................................................. 18
7.3 Factory Testing.............................................................................................. 18
7.4 Configuration Password..............................................................................19
7.5 Device Information........................................................................................19

1
Unit 1 Overview
This product is an Outdoor Station of 2-Wire analog video door phone system, it makes
communication with Indoor Monitor via 2-core cable in the system, the Outdoor Station
also supports access control with IC card.
1.1 Functions and Characteristics
Support video intercom and unlocking
Support real-time monitoring
Door status detection, and unlock state timeout alarm
Support IC card
Support Wiegand output
Support connecting external camera
Support call by name list & call by apartment No.
1.2 Parameters
Working Parameters
Working Voltage: DC 24~32V
Static Current: ≤ 80mA (DC 30V)
Working Temperature: -25℃~55℃
Working Current: ≤ 160mA (DC 30V)
Storage Temperature: -40℃~70℃
Dimension(W/H/D): 324×128×46mm
Camera
Type: CMOS
Resolution: 700TVL
View Angle: horizontal 48°
Min. Illumination: 0.1 lux
White Balance: auto
Fill-in Light: white

2
Unit 2 Appearance and Interface
2.1 Appearance
Front View Rear View
Card Reading Area
Keyped Area
Display Area
Fill-in Light
MIC
Camera
Aluminium Panel
Wire Connecting Area
Speaker

3
2.2 Dimension

4
2.3 Interface Introduction
①Network(update) Interface (1: TX+ , 2: TX-, 3: RX+, 4: RX-);
②External camera input;
③Wiegand output;
④BUS-A 、BUS-B:2-Wire BUS interface;
NO, COM, NC: Normally open pin, Common pin, Normally closed pin;
GS: Door status detection;
DOOR SW: door unlocking switch;
GND: Common ground;
⑤External DC 24V power supply interface;
⑤
④
③
②
②
①

5
Unit 3 Installation
3.1 Installation Height
Suggested height for installation: camera is 1.6m above the ground
Ground

6
3.2 Installation Steps
Step 1: Put the embedded box into the preformed groove (as Pic.2). After getting the
cable out through the opening, fasten the box with screws or by cement. Dimensions of
embedded box are as below:
预埋盒尺寸(W/H/D):如图 1 所示
Step 2: After connecting the cable to the Outdoor Station (as Pic.3), match the snap
slot of the Outdoor Station to the snap of embedded box and press the outdoor station
into the box, then fasten the Outdoor Station to the box with screws (as Pic.4).
Pic.1
Pic.2
Pic.3
Pic.4

7
3.3 System Wiring
Remarks:
1This Outdoor Station is using keypad to make the call, which is suitable for large
system with max. 128 apartments, the wiring topology is shown as above. In addition, it
also supports being installed for villa or other small system.
2Support multiple Indoor Monitors(Max. 4pcs) in 1 apartment, address of all the
Indoor Monitors in one apartment should be same.
Attention: In case of over current, only 1 Indoor Monitor can be set as master
within 1 apartment. Detailed setting refer to the interface introduction of Indoor
Monitor.
3In the case of having multiple Indoor Monitors in 1 apartment, all Indoor Monitors
will ring when they are being called, but only the master Indoor Monitor will shows the
screen. If one Indoor Monitor takes the call, the rest will hangup automatically.

8
4Restricted by the power consumption, the system only allows 2 Indoor Monitors
showing the screen (being operated) at the same time (intercom function is not
affected).
5Distributor is recommended for system wiring (star topology), while Bus topology
(hand in hand connection) is supported as well.
6Wiring distance A is the Max. Length from Outdoor Station to Power Supply, wiring
distance B is the total length from Power Supply to the last Indoor Monitor, wiring length
of different types of cable are shown as below:
Specification
(A+B) length/m
RVV 2*0.75mm²
110
Twisted pair
160

9
Unit 4 Operation Instructions
4.1 Call By Apartment No.
In standby mode, visitors can input apartment No. and press “ #” to make the call, and
the device will enter calling interface.
If Indoor Monitor is offline, it will go back to the standby interface with “Beep”.
If Indoor Monitor is online, it will begin the calling count down and start to play the
ringback.
Calling Interface
4.2 Call By Name List
In standby mode, visitors can press “ ↑↓ ” to enter name list interface (name list should
be imported by PC configuration software in advance).
Name List Interface Name Searching Interface
After pressing “ ↑↓ ” or inputting the user name, press “ #” to enter calling interface.
If Indoor Monitor is online, it will begin the calling count down and start to play the
ringback.

10
4.3 Call Guard Unit
In standby mode, visitors can press to call Guard Unit.
4.4 Unlock
1) Unlock By Swiping Card
Swipe the registered card to the card reading area to unlock the door, and Outdoor
Station will show “door opened”.
2) Unlock By Indoor Monitor
Residents can unlock the door from Indoor Monitor when Outdoor Station is calling or
being monitored by Indoor Monitor, and Outdoor Station will show “door opened”.
3) Unlock By External Button
There is a interface for integration of external push button, when connected, a normal
push button can be used to unlock the door.
4) Public Password Unlock
If this function is activated, residents can press “ #” and wait for 1s to enter public
password interface.
Public Password Unlock Interface
In public password interface, input public password and press “ #” to unlock the door.
Remark: 1. Public Password Unlock function is deactivated as default;
2. Default public password: 666666.

11
5) User Password Unlock
If User Password Unlock function is activated, residents can press “ * # ” and wait for
1S to enter user password interface.
User Password Unlock Interface
In User Password interface, input Apartment No. and related password, then press “ #”
to unlock the door.
Remark: User password needs to be imported by PC configuration tool, detailed
setting refer to PC configuration tool instruction.
Unit 5 Settings
5.1 Setting Login Interface
In standby mode, users can press “ #*” to enter setting login interface.
Default configuration password: 801801.
Setting Login Interface

12
5.2 Main Setting Interface
After inputting the correct configuration password and “ #”, main setting interface is
shown as below, users can press “ ↑↓ ” to choose the item.
Main Setting Interface
Unit 6 System Settings
System setting includes setting of Time, Volume, Language, PIN, Unlock Time, Card
and Wiegand, users can press “ ↑↓ ” to choose the specific setting.
System Setting Interface 1 System Setting Interface 2

13
6.1 Time Setting
Time setting interface is shown as below, users can press “ ↑↓ ” to select each option
and input the number, press “ *” to delete or return. After revising finished , press “ #”
to save and return.
Time Setting Interface
6.2 Volume Setting
Volume setting interface is shown as below, users can press ” #” to adjust, and “ *” to
save and return.
Volume Setting Interface

14
6.3 Language Setting
Language setting interface is shown as below, users can press “ ↑↓ ” to select the
language, press “ #” to save and return.
Language Setting Interface
6.4 PIN Setting
Password setting includes 3 items: On and Off for user password and public
password, and change of public password. Users can press “ #” to adjust, and “ *” to
return.
PIN Setting Interface

15
6.5 Unlocked-Time Setting
Unlocked-time setting is to set the duration of the unlocked time after door opened.
When the time is out, the door will lock again automatically. The unit is "second". Press
"*" key to delete and press " #" key to save and return.
Unlocked-Time Setting Interface
6.6 Card Management
Card management includes registration, check(card information), delete,
clear(delete all) and copy.
Card Management Interface Registration Interface
Swipe a card or input the card number to register, after registering finished, press “ #”
to confirm, or “ *” to return. While inputting card number, users can press “ *” to delete
each number. The operation of card deletion is same as card registration.
Remark: Capacity of registered card: 2000 cards maximum .

16
Users can enter ”check(card information) ” to check all card numbers and the quantity of
registered cards.
Press ” ↑↓ ” to page up/down the card numbers.
Card Information Interface
If you choose the“clear”, a message will come out for you to confirm the
operation(delete all). Press " #" key to confirm, and press " *" key to return.
“Card Copy” function is reserved and coming soon.
Card Copy Interface

17
Unit 7 Configuration Settings
Configuration setting includes address setting, alarm setting, factory testing, project pin,
company info and device info. Press “ ↑↓ ” to enter a particular setting.
Configuration Setting Interface 1 Configuration Setting Interface 2
7.1 Address Setting
Address setting interface is shown as below, address range: 1~32. Press “ #” to
change the address of the current device.
Remark: In case of address conflict, “Building” and “Unit” are fixed, only “No.”
can be changed.
Address Setting Interface
Other manuals for T Series
6
This manual suits for next models
1
Table of contents
Other GVS Intercom System manuals