2 947218
Individual switches for selection of night ring
and time clock tones per output
May be used with 25 or 70 volt amplifiers
AC powered, 230 or 115VAC
Internationally recognized power connector
AC input fused at .5 amp @ 230VAC, 50 Hz or 1
amp @ 115VAC, 60 Hz
115/230 Volt selector switch for international use
UL listed
Dimensions/Weight
7.1”H x 9.0”W x 2.4”D
(18.03cm H x 22.86cm W x 6.10cm D)
3.7 lbs. (1.68kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dbm nominal
Voice Switch Sensitivity: -21dbm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dbm nominal
Output Impedance: 8 Ohms
Output Level: -10dbm nominal
DC Output: 1 amp at -24VDC
Nominal Power Requirements
Voltage: Current:
230VAC .5 Amp
115VAC 1 Amp
The V-2001A-E is equipped with a standard 3-prong
polarized MOLEX connector to allow connection of a
battery backup supply in case of AC power failure.
Use a cord set consisting of a minimum 18 AWG
cord and grounding type attachment plug rated a
minimum of 15A, 250V. The cord set should
have the appropriate safety approvals for the
country in which the equipment will be installed
and should be marked HAR.
The socket outlet shall be installed near the
equipment and shall be easily accessible.
Environment
Temperature: 0 to 40 Degrees C
Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in this
manual is the customer premise equipment such
as an electronic key system, a PABX or a
dedicated single line telephone set(s). The V-
2001A-E is not intended for direct or indirect
connection to the public telephone network or to
PABX analog station ports. When used with a
customer premise telephone system such as a
key system or PABX system, these units are
interfaced to the system via a fully protected page
port or system central office port, which is a fully
protected interface device. Also, the host system
must be configured to disallow central office
trunk conferencing in order to prevent indirect
connection to the public network.
Precautionary Designations
CAUTION: Toreducetheriskof electricshock,
Donotremovecover.
Nouser serviceablepartsinside.
Referservicingtoqualifiedservicepersonnel.
Thissymbol indicatesthatdangerous
voltageconstitutingariskofelectric
shockispresentwithinthisunit.
Thissymbol indicatesthatthereare
important operatingandmaintenance
instructionsintheliteratureaccompanying
thisunit.
CAUTION
RISKOFELECTRICSHOCK
DONOTOPEN
Mounting
The V-2001A-E was designed for wall or table
mounting. Secure unit to wall studs or a suitable
brace away from heat sources or strong magnetic
fields (motors, fans, power supplies, etc.) with the
control and terminal strip accessible. Four wood
screws are included for mounting.
Power Connections
NOTE: This equipment must be installed near an
AC power outlet due to the power cord being
used as a disconnect device.
The V-2001A-E may be used with one of the
following:
-NEMA 5-15 cordset for North American use;
-CEE/7 cordset for Continental European use;
-BS1363 cordset for United Kingdom use.
-Connect cordset to unit via IEC 320 female connector
located on one end of the cordset to IEC 320 male
appliance coupler located on the V-2001A-E.
-For 115VAC use, verify fuse rating of 1 amp and
voltage selector switch displays 115 V.
-For 230VAC use, verify fuse rating of .5 amp and
voltage selector switch displays 230 V.
-After all required connections have been made, plug
the cordset into appropriate AC wall outlet.