Valcom V-2001A User manual

Issue 8
1 947202
V-2001A
SINGLE ZONE (PLUS) PAGE CONTROL UNIT
INTRODUCTION
The V-2001A provides telephone system access
to a single zone of one-way paging.
“WARNING: To reduce the risk of fire or
electric shock, do not expose this equipment
to rain or moisture.”
“WARNING: Shock Hazard - Do Not Open.”
“AVIS: Risque de Choc Electrique ne pas
Ouvrir.”
“PELIGRO: Corriente Electrica - No Abra.”
“CAUTION: To reduce the risk of fire replace
only with same type 1A, 125V fuse. 1A, 125V
may be replaced by a 0.5A, 250V provided
voltage selector is set for 230V.”
“DANGER: Afin de réduire le risque de feu,
remplacez le fusible par le même type de
fusible à 1A, 125V. On peut utiliser un
fusible à 0.5A, 250V pourvu que le sélecteur
ďalimentation soit fixé sur 230V. Ne pas
ouvrir.”
“VORSICHT: Zur verringerung von
feuergefahr die sicherung nur mit derselben
type 1A, 125V ersetzen. Statt 1A, 125V Kann
0.5A, 250V Benutzt werden, vorausgesetzt,
die spannung ist auf 230V eingestellt. Nicht
öffnen.”
“PELIGRO: Para reducir el peligro de
incendio remplazarlo unicamente con un
fusible del mismo tipo 1A, 125V. El fusible
de 1A, 125V podra ser remplazado por uno
de 0.5A, 250V si el selector de voltaje esta
puesto en 230V. No abres.”
SPECIFICATIONS
Access Methods
•Electronic Key System (C. O. Line Position)
•PABX (Loop Start Trunk Port)
•1A2 Key Systems (400 type line card
required)
•600 Ohm Page Port
•Dedicated Single Line Telephone(s)
Features
•Pre-Page Alert Tone
•Page override capability (Using C. O. line
position or loop start trunk port)
•Switchable battery feed for loop start
operation
•RJ-11 for Tip and Ring connections
•AGC on all voice outputs
•Provides audio for up to 150 Valcom
one-way amplified speaker assemblies
•Background music input
•Voice operated VOX to mute music during
page
•Easily accessible music and tone volume
controls
•Removable screw terminal connectors
provided

2
•Supplies 20 Valcom power units for
powering Valcom one-way amplified
speakers (1 Amp -24VDC); Additional power
supplies are required for a quantity of
speakers using over 20 power units
•Page with music outputs (2 provided); music
mutes during page
•Page without music output
•Battery backup input (Use Valcom VPB-260
battery backup supply)
•Time clock/single tone (Contact closure
activated)
•Night ring/warble tone (Closure or 90VAC
activated)
Priority sequence of tones:
Page overrides music
Night ring mixes with music and page
Time clock mixes with music and page
•Individual switches for selection of night ring
and time clock tones per output
•May be used with 25 or 70 Volt amplifiers
•AC powered, 115 or 230VAC
•Internationally recognized power connector
•AC input fused at 1 Amp @ 115VAC, 60Hz
or 0.5 Amp @ 230VAC, 50Hz
•115/230 Volt selector switch for international
use
•UL listed
Dimensions/Weight
•7.06"H x 9.00"W x 2.40"D
(17.93cm H x 22.86cm W x 6.10cm D)
•Weight: 3.7 lbs. (1.68 kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dBm nominal
Output Impedance: 8 Ohms
Output Level: -10dBm nominal
DC Output: 1 Amp at -24VDC
Nominal Power Requirements
Voltage: Current:
115VAC 1.0 Amp
230VAC 0.5 Amp
Battery Backup
The V-2001A is equipped with a standard
3-prong polarized MOLEX connector to allow
connection of a fused output (3 Amp) battery
backup supply (Valcom VPB-260 or equivalent)
in case of AC power failure. Backup time will be
a function of system usage.
•Use a cord set consisting of a minimum 18
AWG cord and grounding type attachment
plug rated a minimum of 15A, 250V. The
cord set should have the appropriate safety
approvals for the country in which the
equipment will be installed and should be
marked HAR.
•The socket outlet shall be installed near the
equipment and shall be easily accessible.
NOTE: The AC line cord of the VPB-260 and
the AC line cord of the V-2001A should be
plugged into the same AC circuit.
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in
this manual is the customer premise
equipment such as an electronic key system,
a PABX or a dedicated single line
telephone(s). The V-2001A is not intended
for direct or indirect connection to the public
telephone network or to PABX analog station
ports. When used with a customer premise
telephone system such as a key system
or PABX system, these units are interfaced
to the system via a fully protected page port
or system central office port, which is a fully
protected interface device. Also, the host
system must be configured to disallow
central office trunk conferencing in order to
prevent indirect connection to the public
network.
Precautionary Designations
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
efer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
CAUTION
ISK OF ELECT IC SHOCK
DO NOT OPEN

3
Mounting
The V-2001A was designed for wall or table
mounting. Secure unit to wall studs or a suitable
brace away from heat sources or strong
magnetic fields (Motors, fans, power supplies,
etc.) with the control and terminal strip
accessible. Four wood screws are included for
mounting.
Power Connections
NOTE: This equipment must be installed
near an AC power outlet due to the power
cord being used as a disconnect device.
•The V-2001A is provided with a NEMA 5-15
cord set for North American use.
•Connect cord set to unit via IEC 320 female
connector located on one end of cord set to
IEC 320 male appliance coupler located on
the V-2001A.
•For 115VAC use, verify fuse rating of 1 Amp
and voltage selector switch displays 115V.
•For 230VAC use, verify fuse rating of 0.5
Amp and voltage selector switch displays
230V.
After all required connections
have been made, plug the cord
set into appropriate AC wall
outlet.
CONNECTIONS
Refer to Figure 1.
Electronic Key or PABX Access
When using the V-2001A with an electronic key
system, C. O. line position or PABX trunk port,
the battery feed switch (SW1) must be ON.
Pre-Page Alert Tone Option
The Pre-Page Alert Tone may be used when
accessing the unit from an electronic key
system, C. O. Line position, PABX Trunk Port or
a Page Port with a contact closure. Page Ports
must provide a contact closure output. To
enable the pre-page alert tone feature, place a
jumper on the yellow and black leads (outer pair
of RJ-11) of J3. (See Figure 1).
NOTE: The pre-page alert tone operates on
the primary paging input only.
Operation: Press line key (Electronic key
system) or dial trunk access code (PABX) to
connect to the paging speakers. Make
announcement. The V-2001A automatically
disconnects from page.
Page Port Access
When accessing the V-2001A from a telephone
system page port, the battery feed switch (SW1)
must be OFF.
Operation: Follow the telephone system
manufacturer's instructions for access to
external paging. Make announcement. The
V-2001A automatically disconnects from page.
The V-2001A voice switching circuit is activated
when the person making the page begins to
speak. When the page is completed or the
person stops speaking for more than two
seconds, the paging circuit turns off. Other
functions of the unit remain the same.
Background Music
Background music may be connected to the
V-2001A when using either access method.
Background music mutes on the "page + music"
outputs when a page is made.
Connect the output of a low level music source
to the screw terminals marked "Music" on the
input terminal strip on the V-2001A. Adjust
music volume control on the V-2001A to the
desired level.
Night Ring and Single Tones
Night ringing (Electronic warble tone) over
paging is activated by a common audible
contact closure or 90VAC ring voltage.
A single tone (Time clock) over paging is
provided when the V-2001A is connected to a
contact closure.
Tone Options
SW4 enables or disables single and warble
tones on all page outputs. SW2 enables or
disables single tones and warble tones on the
page without music output only.

4
Operation: Night Ring & Single Tones
PAGE WITHOUT MUSIC OUTPUTS:
SW2 SW4
No Tones OFF OFF
Tones ON ON
PAGE WITH MUSIC OUTPUTS:
SW2 SW4
No Tones OFF
Tones ON
Page Override
Page override requires the use of a vacant
C. O. line position, vacant loop start trunk port or
dedicated single line telephone set for access
(In addition to the page port, vacant C. O. line
position or vacant loop start trunk port used for
primary access of the V-2001A).
Using a modular telephone cord, connect the
V-2001A RJ11 jack labeled "Tip and Ring OVR"
to the phone system vacant C. O. line position or
vacant loop start trunk port.
Operation:Press line key (Electronic key
system) or dial trunk access code (PABX) for
page override access to connect to paging
speakers (Overriding page in progress). Make
announcement. The V-2001A disconnects
when phone is hung up, re-establishing the
overridden page announcement.
Connection of One-way Amplified
Speakers
The Valcom V-2001A provides external power of
20 power units (1 Amp -24VDC) to operate one-
way amplified speakers. Additional power
supplies are required for a quantity of speakers
using over 20 power units. When using
additional power supplies, make certain:
1) The -24VDC outputs are not connected
to each other.
2) Each speaker is connected to only one
power source.
Volume Adjustments
The page volume is set by the speakers. Adjust
speakers 1/3 to 1/2 volume initially, test and
reset if necessary for correct page volume.
There are two volume controls for individual
adjustment of:
•Background music
•Tones (Warble/single tone)
Clockwise adjustment increases volume,
counter clockwise adjustment decreases
volume.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. Check voltages for proper polarity
to the one-way amplified speakers. Table 1
identifies symptoms of some possible
problems with solutions. If a spare unit is
available, substitute a spare unit for the
suspected defective unit.
Assistance in troubleshooting is available from
the factory. When calling, you should have a
telephone test set, several clip leads, a VOM
available and call from the job site. Call
(540) 563-2000 and press 1 for Technical
Support or visit our website at
http://www.valcom.com.
The V-2001A is not field repairable. Valcom
equipment contains no user serviceable parts
inside. Valcom, Inc. maintains service facilities
in Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number,
contact person and the nature of the problem.
Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056

5
J3
J2
SW4SW2
SW1
R2
R40
ON
OFF
MUSIC
VOL.
TONES
VOL.
J1
J8
BATT.
FEED TIP AND
RING PAGE
TIP
AND
RING
OVR
PAGE R
PAGE T
MUSIC
CLOCK/STEADY TONE
UNA/WARBLE TONE
PC
-24V
GND
-24V
GND
PAGE W/
MUSIC
PAGE W/
MUSIC
INPUTS
OUTPUTS
T
R
OR
Optional Background
Music Source
NOTE: Battery Feed Switch
ON - E-Key or PABX Loop
Start Trunk Port Access
OFF - Page Port Access
V-2001A
CAUTION: VORSICHT:
DANGER: PELIGRO:
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
FIGURE 1: V-2001A CONNECTORS, CONTROLS, MOUNTING ORIENTATION AND ACCESS CONNECTIONS
UNA RINGING
PAGE w/o
MUSIC
GND
-24V
PPCC
Optional contact
operation when VOX
operation is not desired
CONTACT
CLOSURE
ACTIVATION
TONES
ON
OFF
ON
OFF
SW2, SW4
ON = ENABLE
OFF = DISABLE
OR
VACANT
C.O. PORT
PAGE PORT
Green
TIP
Yellow
RING
J3
Red
Black
APPLY JUMPER ON RJ-11
PRE-PAGE ALERT TONE
BLOCK TO ENABLE

6
TABLE 1: TROUBLESHOOTING CHART
SYMPTOMS PROBABLE CAUSES AND SOLUTIONS
1. No output to speakers A. Check for the presence of audio on the page outputs of the V-2001A during a
page using a test set. Refer to installation section for connection information.
B. Check AC line fuse on V-2001A.
2. No music output A. Using a test set, check for music on the music input terminals.
B. Check that speakers are connected to “page + music” outputs.
3. No warble tone output A. If a contact closure is provided by the telephone system, use an Ohm meter to
check the continuity of the contact closure when the contact closure accesses
the unit.
B. If ringing is used, with an AC Volt meter, check for the presence of ring voltage
when a call is ringing into the telephone system.
C. Check selector switches (SW2 and SW4).
4. No single tone output A. Using an Ohm meter, check the contact closure on the device that is to operate
the single tone.
B. Check selector switches (SW2 and SW4).
NOTE: The contact closure operation of the V-2001A can be tested with a length of wire connected between
the two terminals of either the UNA/warble or clock/steady tone inputs.
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal
use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited
to the replacement, repair or refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are
unopened (a service charge plus parts and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (major
repairs will be subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall
Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses
incurred by the buyer in connection with the purchase, operation or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged
condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved
in accordance with the F.O.B. point.
Headquarters: In Canada
Valcom, Inc. CMX Corporation
5614 Hollins Road 35 Van Kirk Drive #11 and 12
Roanoke, VA 24019-5056 Brampton, Ontario L7A 1A5
Phone: (540) 563-2000 Phone: (905) 456-1072
FAX: (540) 362-9800 FAX: (905) 456-2269
Other manuals for V-2001A
2
Table of contents
Other Valcom Control Unit manuals

Valcom
Valcom V-2001 User manual

Valcom
Valcom V-2003A User manual

Valcom
Valcom V-2003A-E User manual

Valcom
Valcom V-119RTHF User manual

Valcom
Valcom V-2001 User manual

Valcom
Valcom V-9941A User manual

Valcom
Valcom V-2000A User manual

Valcom
Valcom V-2003A User manual

Valcom
Valcom V-2992 User manual

Valcom
Valcom V-2001A User manual

Valcom
Valcom V-2992 User manual

Valcom
Valcom V-1097 User manual

Valcom
Valcom V-2001A-E Reference manual

Valcom
Valcom VIP-848 User manual

Valcom
Valcom V-9941A User manual

Valcom
Valcom V-1134 User manual

Valcom
Valcom V-2000A User manual

Valcom
Valcom V-2001A User manual

Valcom
Valcom V-9933A User manual

Valcom
Valcom V-9933A User manual