manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Valcom
  6. •
  7. Control Unit
  8. •
  9. Valcom VIP-848 User manual

Valcom VIP-848 User manual

Other Valcom Control Unit manuals

Valcom V-9933A User manual

Valcom

Valcom V-9933A User manual

Valcom V-1134 User manual

Valcom

Valcom V-1134 User manual

Valcom VIP-848A User manual

Valcom

Valcom VIP-848A User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-119RTHF User manual

Valcom

Valcom V-119RTHF User manual

Valcom V-1097 User manual

Valcom

Valcom V-1097 User manual

Valcom V-2992 User manual

Valcom

Valcom V-2992 User manual

Valcom V-9941A User manual

Valcom

Valcom V-9941A User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-2001A-E Reference manual

Valcom

Valcom V-2001A-E Reference manual

Valcom V-2992 User manual

Valcom

Valcom V-2992 User manual

Valcom V-9933A User manual

Valcom

Valcom V-9933A User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-9941A User manual

Valcom

Valcom V-9941A User manual

Valcom V-2001 User manual

Valcom

Valcom V-2001 User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Valcom V-2001 User manual

Valcom

Valcom V-2001 User manual

Valcom V-2003A-E User manual

Valcom

Valcom V-2003A-E User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1 947645
Issue 2
VIP-848
Networked Input & Relay Module
INTRODUCTION
The VIP-848 Networked Input & Relay Module
allows passing of contact closures, which are
software programmable to be either form A or
form B, and initiation of VIP-601 server events
over an IP-based LAN/WAN. Multiple VIP-848
Networked Input & Relay Modules can be used on
the same network to create very large and
distributed systems.
SPECIFICATIONS
Features
8 Relay Contacts That Are Programmable To
Form A or Form B
8 Contact Closure Inputs
RJ-45 For Network Connection
Front Panel Activity LED
Removable Screw Terminal Connector
Provided For Input And Relay Interface
2.5mm Jack For DC Power
Power Over Ethernet 802.3af Compliant
No Server Required
1 to 11 Digit Dial Plans
Easy Windows Based Setup
Dimensions/Weight
1.50”H x 6.19" W x 5.88" D
(3.81cm H x 15.72cm W x 14.94cm D)
Weight: 1.00 lbs. (0.45 kg)
Nominal Specifications
Input Impedance: 10k Ohms
Relay Current: 1 AMP @ 24VDC
Protocols: DHCP, IGMP v3, UDP, TCP, HTTP,
Telnet, FTP
Nominal Power Requirements
Via Back Panel Barrel Connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch:
802.3af: Class 3
Environment
Temperature: +32 to +104°F (0 to +40°C)
Humidity: 0 to 85% Non-Precipitating
Packing List
Qty
Item
1
VIP-848
1
VIP Setup CD
1
VSP Document
2
Mounting Brackets
4
Rubber Feet
6
Wood Screws
1
RJ-45 Patch Cable
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 389-0000
2 947645
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment
in a residential area may cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Precautionary Designations
Mounting
The VIP-848 is designed for wall, table or rack
mounting.
Table: Provided with the VIP-848 are four rubber
stick on feet. Peel these feet off their carrier
backing and place at the four corners of the
bottom of the unit.
Wall: Using the template and instructions
provided, secure the VIP-848 to the wall.
Rack: Following the assembly drawing, attach the
two mounting ears to the VIP-848 unit. Using rack
screws, mount the VIP-848 in an available 1U
rack slot.
Power Connections
The preferred method of powering a VIP-848 is
via a Power over Ethernet (PoE) switch meeting
the 802.3af specification.
If the rear panel barrel connector is used for
power, the preferred power supply is a Valcom
VIP-324.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the rear
panel are made then connect the VIP-848 to the
Ethernet switch.
If power is provided via the barrel connector,
make sure all signal connections are secure.
Attach the unit to the network via the front panel
RJ-45 Ethernet connector. Apply power by
plugging the power supply in to the VIP-848 via
the barrel connector on the rear of the VIP-848.
Network Connection
The VIP-848 has one CAT-5 RJ-45 network
connector on the front panel.
Use the supplied CAT-5 patch cable to connect
the VIP-848 to an Ethernet switch. If the Ethernet
switch is 802.3af compliant the VIP-848 will draw
power from it.
Signal Connections
The VIP-848 has 16 signal connectors on the rear
panel:
8 Contact Closure Inputs
8 Relay Contacts that are programmable as
Form A or Form B
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 389-0000
3 947645
Status Indicator Lights
The VIP-848 has 3 status indication lights on the
front panel:
Front View
Rear View
STATUS: Flashes to indicate power.
LINK: Indicates 100 Mbit Ethernet connection
when illuminated. No activity indicates 10 Mbit
connection.
ACT: Indicator flashes to indicate network activity.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. Check voltages for proper polarity to
the one-way amplified speakers. If a spare unit is
available, substitute a spare unit for the suspected
defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
support@valcom.com.
When requesting assistance, you should include
all available information. It is strongly suggested
that you go to the web site and follow the trouble
resolution procedure at http://voip.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one
year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device
within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus
parts and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or
use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Phone: (540) 563-2000
FAX: (540) 362-9800
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 389-0000