1 947645
Issue 5
VIP-848A
Networked Input & Relay Module
INTRODUCTION
The VIP-848A Networked Input & Relay Module
allows passing of contact closures, which are
software programmable to be either Form A or
Form B, over an IP-based LAN/WAN. Multiple
VIP-848A Networked Input & Relay Modules can
be used on the same network to create very large
and distributed systems.
SPECIFICATIONS
Features
8 Relay Contacts That Are Programmable To
Form A or Form B
8 Contact Closure Inputs
RJ-45 For Network Connection
Front Panel Activity LED
Removable Connector Provided For Input And
Relay Interface
2.5mm Jack For DC Power
Power Over Ethernet (PoE) 802.3af
Compliant
No Server Required
1 to 11 Digit Dial Plans
Easy Windows Based Setup
Dimensions/Weight
1.50” H x 6.19" W x 5.88" D
(3.81cm H x 15.72cm W x 14.94cm D)
Weight: 1.00 lbs. (0.45 kg)
Nominal Specifications
Input Impedance: 10k Ohms
Relay Current: 1 AMP @ 24VDC
Nominal Power Requirements
Via Back Panel Barrel Connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch:
802.3af: Class 3
Environment
Temperature: +32 to +104°F (0 to +40°C)
Humidity: 0 to 85% Non-Precipitating
Packing List
Qty Item
1 VIP-848A
1 VSP Document
2 Mounting Brackets
4 Rubber Pads
2 947645
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates thatthere are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment
in a residential area may cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Precautionary Designations
Mounting
The VIP-848A is designed for wall or table
mounting.
Table: Provided with the VIP-848A are four
rubber stick on pads. Peel these pads off their
carrier backing and place at the four corners of
the bottom of the unit.
Wall: Using the bracket and hardware provided,
secure the VIP-848A to the wall.
Power Connections
The preferred method of powering a VIP-848A is
via a Power over Ethernet (PoE) switch meeting
the 802.3af specification.
If the rear panel barrel connector is used for
power, the preferred power supply is a Valcom
VIP-324D.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the rear
panel are made then connect the VIP-848A to the
Ethernet switch.
If power is provided via the barrel connector,
make sure all signal connections are secure.
Attach the unit to the network via the front panel
RJ-45 Ethernet connector. Apply power by
plugging the power supply in to the VIP-848A via
the barrel connector on the rear of the VIP-848A.
Network Connection
The VIP-848A has one RJ-45 network connector
on the front panel.
Use a standard Ethernet patch cable to connect
the VIP-848A to an Ethernet switch. If the
Ethernet switch is 802.3af compliant the VIP-848A
will draw power from it.
Signal Connections
The VIP-848A has 16 signal connectors on the
rear panel:
8 Contact Closure Inputs
8 Relay Contacts that are programmable as
Form A or Form B
3 947645
Status Indicator Lights
Rear View
STATUS: Flashes to indicate power.
LINK: Indicates 100 Mbit Ethernet connection
when illuminated. No activity indicates 10 Mbit
connection.
ACT: Indicator flashes to indicate network activity.
SETUP:
Information specific to your application will need
to be programmed into the VIP-848A using a
computer. The PC used for programming should
be connected to the same subnet as the
VIP-848A.
Setup will be done using the IP Solutions Setup
Tool. Download the latest version of the free IP
Solutions Setup Tool from the Valcom web site at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
[email protected].
When requesting assistance, you should include
all available information. It is strongly suggested
that you go to the web site and review the
information at www.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the
specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800

Other Valcom Control Unit manuals

Valcom V-9941A User manual

Valcom

Valcom V-9941A User manual

Valcom V-2001 User manual

Valcom

Valcom V-2001 User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-9933A User manual

Valcom

Valcom V-9933A User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Valcom V-2001 User manual

Valcom

Valcom V-2001 User manual

Valcom V-1134 User manual

Valcom

Valcom V-1134 User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-9933A User manual

Valcom

Valcom V-9933A User manual

Valcom V-119RTHF User manual

Valcom

Valcom V-119RTHF User manual

Valcom V-2001A User manual

Valcom

Valcom V-2001A User manual

Valcom VIP-848 User manual

Valcom

Valcom VIP-848 User manual

Valcom V-2003A-E User manual

Valcom

Valcom V-2003A-E User manual

Valcom V-1097 User manual

Valcom

Valcom V-1097 User manual

Valcom V-2992 User manual

Valcom

Valcom V-2992 User manual

Valcom V-9941A User manual

Valcom

Valcom V-9941A User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-2000A User manual

Valcom

Valcom V-2000A User manual

Valcom V-2003A User manual

Valcom

Valcom V-2003A User manual

Valcom V-2992 User manual

Valcom

Valcom V-2992 User manual

Valcom V-2001A-E Reference manual

Valcom

Valcom V-2001A-E Reference manual

Popular Control Unit manuals by other brands

LUNATONE DALI Daylight manual

LUNATONE

LUNATONE DALI Daylight manual

Intelix DIGI-P122 Operation guide

Intelix

Intelix DIGI-P122 Operation guide

Asus Aaeon NanoCOM-APL user manual

Asus

Asus Aaeon NanoCOM-APL user manual

Mircom RB-MD-950 Replacement instructions

Mircom

Mircom RB-MD-950 Replacement instructions

M-system R3-PT4 instruction manual

M-system

M-system R3-PT4 instruction manual

ICP DAS USA PET-7261 quick start guide

ICP DAS USA

ICP DAS USA PET-7261 quick start guide

NetworX NX Series installation instructions

NetworX

NetworX NX Series installation instructions

General Pump ZH284KEZ quick start guide

General Pump

General Pump ZH284KEZ quick start guide

LG WL1BKR22 user manual

LG

LG WL1BKR22 user manual

ICP ET-2242U quick start

ICP

ICP ET-2242U quick start

Lefroy Brooks CT 8700 installation guide

Lefroy Brooks

Lefroy Brooks CT 8700 installation guide

Global M3 SYSTEM operating manual

Global

Global M3 SYSTEM operating manual

Emerson Sempell series Installation and maintenance instructions

Emerson

Emerson Sempell series Installation and maintenance instructions

NEC ASPV46-AVT - AccuSync - 46" LCD TV Setup

NEC

NEC ASPV46-AVT - AccuSync - 46" LCD TV Setup

ABB REC 523 Technical reference manual

ABB

ABB REC 523 Technical reference manual

Sit 440 D3 quick start guide

Sit

Sit 440 D3 quick start guide

Deditec USB-RELAIS-8 Hardware description

Deditec

Deditec USB-RELAIS-8 Hardware description

Balluff BNI EIP-306-100-Z010 user guide

Balluff

Balluff BNI EIP-306-100-Z010 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.