Owner’s Manual
LifeSine LSC12-1100 Owner’s Manual - 5 -
S CTION 3: SP CIFICATIONS
Inverter LSC12-1100
Continuous Output Power Rating 1100 Watts (9.2 amps)
Surge Capacity (3 sec) 2200 Watts
DC Input Vo tage, VDC 12 VDC Nomina , 10.5 VDC min,16.5 VDC max.
AC Output Vo tage 120 VAC ± 5%
AC Output Wave Form True Sine Wave (THD < 3% @ inear oad)
AC Output Frequency 60 Hz or 50 Hz, ± 0.3 Hz, User Se ectab e
DC Current Draw from Battery
Inverter OFF 0.0 Amps
Inverter ON in Load Demand Approx. 0.08 Amps
Inverter ON, Load Demand OFF, with No AC Load Approx. 1.4 Amps
Inverter ON with AC Load Approx. AC Load Watts ÷ 10
Battery Charger
AC Input Vo tage 120 VAC Nomina (90VAC min, 132VAC max)
AC Input Frequency 60Hz or 50Hz, ± 3 Hz
AC Input Amps 7.5 Amps AC Max (Approx. DC Output Amps ÷ 7)
Charging Capacity (Inc udes 12V DC Output Power Source)
12 Amps DC, 25A, 37A, or 50A, User Se ectab e
Battery Type * F ooded AGM LiFePO4
Bu k Vo tage 14.2 VDC 14.4 VDC 14.4 VDC
Absorption Vo tage 14.1 VDC 14.3 VDC 14.4 VDC
F oat Vo tage 13.2 VDC 13.6 VDC 14.0 VDC
Bypass Transfer Switch Rating
AC Output Current to GFCI Output Receptac e 12 Amps AC
Automatic Power Management
Maximum AC Current Drawn from Shore Power 12 Amps AC (Battery Charging is reduced as needed.)
12V DC Output Power Source
Output Vo tage Battery Vo tage
Output Current 20 Amps DC Max. (Subtract Power Source output
amps from Charging Capacity)
Other Specifications
AC Input Termination** 3 Ft 120 VAC 15 Amp Line Cord
AC Output Termination *** Dup ex GFCI Receptac e
DC Input Termination 175 Amp Anderson Sty e Two-po e Connector
Ambient Operating Temperature at fu power -4°F to +104°F
Ambient Operating Temperature at de-rated power De-rate to zero watts at +158°F
Coo ing Air Coo ed by Variab e Speed Intake Fan
Chassis A uminum
Dimensions 11.57”W x 5.94”H x 11.4”D****
Weight 9.5 pounds
Safety Standards Certified UL/cUL 458
* DO NOT use GEL batteries if charging vo tages do not meet the Battery Manufacturer’s specifications.
Consu t GEL Battery Manufacturer before using GEL batteries.
** AC input branch rated overcurrent protection is to be provided by others to comp y with the Nationa E ectric
Code, NFPA 70.
*** If the GFCI trips whi e on inverter power and the Load Demand Feature is enab ed, the GFCI cannot be re-
set unti the inverter is turned OFF and back ON. Turn the inverter OFF and back ON, and reset the GFCI
within 10 seconds before the inverter goes back into Load Demand mode.
**** A ow approx. 3.5” c earance behind the inverter for access to connect/disconnect the Anderson connector.