Vaxcel T0277 Instruction manual

Page 1 / 5
Important to Know:
1. If you are not familiar with state and local electrical
codes, it is recommended that you consult with a
qualified electrician.
2. This fixture requires a 120 VAC, 60 Hz power
source.
3. For general safety and to avoid any possible
damage to the sensor, be sure the power is
switched "off" before adjustment.
Maximum Wattage: 22 W
Working Temperature Range: -40F ~ 1130F
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THESE INSTRUCTIONS.
T0277
Features:
WARNING:
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF
POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.
Note: Fixture can be wall mounted or eave mounted.
Wall Mounted Eave Mounted
For eave mounted only:
Rotate the sensor head towards the mounting bracket. Rotate the sensor head clockwise 180˚ so the controls face down.
Controls
Mounting Bracket Controls
Controls
1. Energy saving LED fixture.
2. Motion sensor: turns light ON automatically when
motion is detected and turns light OFF automatically
when motion stops.
3. Photocell keeps the light OFF during daylight hours.
4. When in manual override mode, use wall switch
to keep the light ON during the night.
Hardware Package (included):
Decorative cover
Mounting Bracket Screw Fixture Mounting Screw
Mounting Strap Wire Connector X3
Mounting Screw X2
#8/32X1/2 in
Mounting Screw X2
#6/32 X1/2 in
Mounting Screw X2
#10/24 X1/4 in
Read notes section on page 4 for additional information about mounting location of fixture.
Light fixture and sensor should be mounted as shown above when installed (depending upon type of installation).
Before installing the light fixture under an eave, the sensor head must be rotated as shown in the next two steps for
proper operation and to avoid the risk of electrical shock.
160729

Page 2 / 5
Installation Steps
Mounting Strap
Mounting Bracket
Outlet Box
Wire Connector
Back Plate
Mounting Screw
Light Head
Fixture Mounting Screw
Mounting Bracket Screw
FRONT Decorative cover
Sensor
1. The mounting bracket is pre-assembled on the light fixture. Unscrew the
decorative cover, fixture mounting screw in order to remove the mounting
bracket.
2. Install the mounting strap to the outlet box with the stamped word “FRONT”
facing away from the outlet box, using two mounting screws that best fit the
outlet box. Mounting bracket should sit flush against wall surface when
secured. (Choose one matching pair of suitable mounting screws from the 3
pairs provided)
3. Pull out the source wires from the outlet box. Make wire connections using
wire connectors as follows:
---Connect the black wire from the fixture to the “hot” wire from the power
source. (usually black)
---Connect the white wire from the fixture to the neutral wire from the power source. (usually white)
---Connect the grounding wire from the fixture to the grounding wire from the power source. (usually green / yellow
insulation)
Carefully tuck the wires back into the outlet box.
4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole,
thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely.
▲ When mounting to a wall, the “UP” arrow must point upward. (See Fig. 1)
▲ When mounting to an eave, the “UP” arrow must point toward the building.
5. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw.
6. Push the decorative cover firmly into the fixture mounting screw hole on the light fixture.
7. With silicone caulking compound, caulk completely around where the mounting bracket meets the wall surface.
CAUTION: Be sure to caulk completely where the mounting bracket meets the wall surface to prevent water
from seeping into the outlet box.
Turn off the power at fuse or circuit box.
Turn on the power at fuse or circuit box.
L (Black)
N (White) GND
Fig. 1
Adjusting the Sensor Head:
1. Aim sensor head toward desired detection area, maintaining a 5° - 40° downward
angle to allow moisture to drain.
Note: Make sure sensor head is positioned with control knob facing towards
the ground.
160729
sensor
Fig. 2

Page 3 / 5
Adjustment Sensor Lower For Short Coverage
Adjustment Sensor Higher For Long Coverage
Fig. 3 Fig. 4
Adjusting the Light Head:
1. Gently grasp the light heads and tilt them up or down, left or
right to adjust the light coverage area. Keep the light heads
at least 1” (25mm) away from the sensor.(See Fig. 5)
2. Keep the light heads 30˚ below horizontal to avoid water
damage and electrical shock.
3. Adjust the light heads up or down, but do not rotate the light
heads more than 60° below horizontal.
Fig. 5
Function and Operation
MODES OF OPERATION
Choose a mode by rotating the switch on the bottom of the sensor of the fixture. (See FIG.7 on page 4)
Note: When power is first applied, the light will turn on immediately. Wait for 30 seconds to allow the sensor
to warm up, then the light will automatically turn off.
1. TEST MODE (daytime and nighttime operation.)
●The light will turn on when the switch located on “TEST” position. The light turns on automatically when motion
is detected, and will stay on as long as motion continues. About 5 seconds after motion is no longer detected,
the light turns off automatically.
2. AUTO MODE (nighttime operation only; on at dusk, off at dawn)
● To shift to the “AUTO” mode, rotate knob arrow to point to the desired time setting within the TIME range. At
dusk, the light turns on when motion is detected, and will stay on as long as motion continues. When the
motion stops, the light will remain on for the predetermined time as you set (5 ~ 180 seconds), and then
turns off automatically.
● The light will turn off automatically at dawn.
3. Manual Override (nighttime operation only; on at dusk, off at dawn)
● To temporarily override the settings in “AUTO” mode for
on-demand continuous full-brightness at night, set the
knob arrow to point to TIME range. Turn the wall switch
“OFF”, and turn it “ON” twice within 3 seconds. The light
will remain on all night long. To shift back to the “AUTO”
mode, turn the wall switch “OFF”, and turn it “ON” twice
within 3 seconds again.
● The light will turn off automatically at dawn.
Note: To make sure the above functions operate properly,
always keep the wall switch in the “ON” position
(including the daytime).
AUTO Mode Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON
-OFF-ON in 0.5~3
Seconds
Turn wall switch OFF-ON
-OFF-ON in 0.5~3 Seconds
Fig. 6
2. You can rotate the sensor head up and down to change the coverage area. (See Fig. 2) Walk through the detection
zone at the farthest distance you wish to detect motion.
Note: Range set too high may increase false triggering. (See Fig. 3 and Fig. 4)
160729

Page 4 / 5
Notes:
1. The sensitivity of the motion sensor will increase as the
environmental temperature gets cooler. You may wish to
make adjustments when the season changes.
For best performance, gently clean the lens with a soft
cloth every 1 or 2 months to assure maximum sensitivity.
2. For best performance, install fixture at least 8 feet above
the ground. At such a height, the fixture will provide a
detection distance of up to 70 feet at 77 degrees
Fahrenheit. (See Fig.8)
3. The sensor detects movement across a detection range
of 180 degrees. (See Fig.9)
4. The sensor will be more sensitive to motion across its
detection path than motion directly towards it. (See Fig.10)
5. To reduce possible nuisances, do not mount the fixture
near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflecting object or
other light source.
Troubleshooting
---The light does not come on at all:
1. Make sure the wall switch and circuit breaker are on.
2. Make sure the wiring is correct.
3. Cover the sensor with dark color cloth to verify that the ambient light level is not too high.
---In TEST Mode, the light stays on over 5 seconds after motion is no longer detected:
1. Make sure the knob arrow is at the TEST position.
2. Cover the sensor with a dark color cloth to verify that motion is not detected.
---In AUTO Mode, the light stays on over 180 seconds after motion is no longer detected:
1. Make sure there is no movement that could be picked up by the sensor.
2. Make sure of that mode entry is not in manual override.
---In Manual override, the light stays on after dawn:
1. The ambient light level may be too low due to overcast skies.
Motion
Least sensitive
Motion
Most sensitive
Sensor
10'
8.0'
12.0'
70'
Where you install your fixture is important:
Be sure the light is mounted straight on the wall
or eave; otherwise, the detection distance may
be limited.
Fig. 8 Fig. 9
Fig. 10
180˚
FIG.7 (View from Bottom of Sensor)
Fig. 7
Customization Options:
Shut-off Delay
● The shut-off delay is the length of time the light will stay at
brightness after motion has ceased to be detected.
● You can set the shut-off delay by rotating the delay time
knob arrow so it points to the desired time setting within
“TIME” range. To increase the shut-off delay, turn the
knob clockwise. To decrease the shut-off delay, turn the
knob counterclockwise.
● The light will stay on as long as motion is detected and
will automatically turn off when no more motion is
detected after the shut-off delay time has passed.
160729

Page 5 / 5
5-YEAR LIMITED WARRANTY:
All products are warranted to be free of defects in material and workmanship for five (5) years from date of purchase.
This warranty is limited to the correction of any such defect, or the replacement of any such defective item(s), provided
that: (a) we are properly notified and consent to return of the item(s) in question:(b) the item(s) is / are returned with proof
of purchase date; and (c) it is found upon inspection by us that the item(s) is / are defective as noted above. This warranty
does not cover labor costs, consequential damages, nor does it apply to any item(s) that have been improperly installed,
overloaded, altered, or otherwise abused by the customer, its agent(s) or employee(s). Finishes are specially excluded
from the terms of this warranty since they are subject to environmental maintenance deemed beyond our control. Other
than the described obligation, we assume no further liability with respect to the sale or use of our products.We make no
warranty, express or implied, and disclaim any warranty of merchantability or fitness for a particular purpose.
Assembly Kit
5076MM
(1 SET)
A: 10-1/8"
B: 6-1/2"
C: 6"
The following parts are available for re-order if damaged or missing.
Decorative cover
Mounting Bracket Screw Fixture Mounting Screw
Mounting Strap Wire Connector X3
Mounting Screw X2
#8/32X1/2 in
Mounting Screw X2
#6/32 X1/2 in
Mounting Screw X2
#10/24 X1/4 in
160729
C
A
B
Spare Parts List:
Table of contents
Other Vaxcel Accessories manuals