PRACTI-BABY PLUS PACK
CERTIFICATE OF WARRANTY
PRACTI-BABY PLUS LIFELIKE INFANT MANIKIN
INCLUDES
1 Practi-Baby Plus, 1 Monitor, 1 User manual, 4 lungs, 2 valves, 2 batteries 9V and 1 transport bag.
Practi-Baby's size, weight and movements are suitable for performing correct infant CPR, adapting to training needs.
This product has successfully passed the most stringent quality
controls before leaving the factory. However, any malfunction due to
assembly and / or components faults, please read the warranty and
contact with the official distributor of the area.
VICEDO MARTI S.L. warrants this product to be free from defects in
material and manufacture at the time of purchase for a period of
TWO YEARS from invoice date of the purchase.
If during the period of the warranty, there is a product defect
attributable to the manufacturing process, material failure and / or
manufacture, the consumer shall inform to the official distributor
within 10 business days after learning of the defect, and at the official
distributor discretion, the product will either be repaired or replaced.
CONDITIONS OF WARRANTY:
Details and documentation: A copy of the invoice covering the
purchase of your product is required to have warranty coverage. In
addition to specifics of the product purchase, the invoice must
provide the following information: name and address of the buyer.
Exclusions:This warranty specifically excludes the following:
-Damage and / or defects to the product resulting from misuse, or
negligence of the user, including the use of the product for purposes
other than its intended use.
-Damage and / or defects caused by the use of external agents such
as lime or other noxious chemicals or corrosives.
-Damage and / or defects due to improper maintenance or lack of
cleaning.
-Damage and / or defects arising from use of manikin parts not made
by the manufacturer of the manikin.
Geographical coverage: The warranty is extended to all countries
where this product is sold by a distributor, VICEDO MARTI S.L. or
assigned by VICEDO MARTI S.L.
Cancellation of the warranty: Product warranty is cancelled:
- In cases of damage caused by repairs performed by persons other
than authorized service agents of VICEDO MARTI S.L., and / or if
parts or accessories are used in the manikin other than original parts
or accessories manufactured by VICEDO MARTI S.L.
- By changing the data on the invoice, sales receipt or packing slip.
VICEDO MARTI S.L. TEL. +34 965 554 708
C/ Ávila, 2 - 03440 Ibi - SPAIN
www.practiman.com - [email protected] - [email protected]
AED TRAINING
Pads do not leave residue on the skin.
To practice with a Guedel airway, remove the valve, replace the skin and
then measure and insert the airway.
CHOKING PRACTICE
Excellent performance during
practice with pediatric resuscitator. The head tilt enables students to learn
the correct breathing technique.
PERFORM REALISTIC BREATHING
KEY FEATURES AND FUNCTIONS
OTHER ADVANTAGES OF PRACTI-BABY PLUS
GUEDEL AIRWAY
ASSEMBLING
PRACTI-BABY PLUS
Remove the chest skin. Remove the face skin. Move the lung to below the jaw.
Connect the lung to the valve. Make sure the valve is correctly attached
to the head.
Fit the face skin, checking that the
nose, mouth and upper tab are in the
correct position.
LUNG
(Ref. SP-001 (PB))
VALVE
(Ref. SP-002 (PB))
FACE SKIN
(Ref. Face-PB)
CHEST SKIN
(Ref. Chest-PB)
CLEANING AND DISINFECTION
RECOMMENDATIONS
To ensure maximum hygiene, the manufacturer recommends thorough cleaning of the Practi-Baby Plus as
per instructions below:
For more thorough disinfection, immerse the face skin in a
container of disinfectant, wash carefully and store dry for
correct use.
The manikin must be cleaned by disinfecting the lips and
face, removing the face skin from the head after each
training session.
After each use, the Practi-Baby Plus valve must be
disinfected and allowed to dry for correct functioning.
The Practi-Baby Plus lung is semi disposable, and can be used
to train group of people in a session without needing to change
it. If the chest stops rising during the practice session, check that
the lung is not moist. If it is, replace it with a new one.
Face shields provide additional protection during training sessions. To keep the manikin perfectly
clean, use the sanitising wipes.
PROTECTION DURING CPR TRAINING SESSIONS
PRACTI-BABY SPARE PARTS
Place the lung on the chest.
Place chest skin and attach to the studs.
12
8

Popular Educational Equipment manuals by other brands

Festo MPS 200 Getting started

Festo

Festo MPS 200 Getting started

Copernicus Royal Inspiration Station Assembly guide

Copernicus

Copernicus Royal Inspiration Station Assembly guide

Sphero RVR RV01 user manual

Sphero

Sphero RVR RV01 user manual

laerdal Multi-Venous IV Training Arm Directions for use

laerdal

laerdal Multi-Venous IV Training Arm Directions for use

LeapFrog Quantum Leap Explorer Parent guide & instructions

LeapFrog

LeapFrog Quantum Leap Explorer Parent guide & instructions

Nasco Healthcare IV TRAINING ARM AND HAND instruction manual

Nasco Healthcare

Nasco Healthcare IV TRAINING ARM AND HAND instruction manual

VATA 2365 user manual

VATA

VATA 2365 user manual

Consequential Robotics MiRo-E owner's guide

Consequential Robotics

Consequential Robotics MiRo-E owner's guide

DIVERSIFIED WOODCRAFTS ARS-4030 Assembly instructions

DIVERSIFIED WOODCRAFTS

DIVERSIFIED WOODCRAFTS ARS-4030 Assembly instructions

project mc2 Perfume Maker 546931 user manual

project mc2

project mc2 Perfume Maker 546931 user manual

Copernicus ELS1 manual

Copernicus

Copernicus ELS1 manual

Limbs & Things 60000 user guide

Limbs & Things

Limbs & Things 60000 user guide

Rompa 18820 Assembly instructions

Rompa

Rompa 18820 Assembly instructions

Rocket R150+ instructions

Rocket

Rocket R150+ instructions

Aircatglobal VirtualFly VF-G1000 user manual

Aircatglobal

Aircatglobal VirtualFly VF-G1000 user manual

Tobii Dynavox TD Pilot Getting started guide

Tobii Dynavox

Tobii Dynavox TD Pilot Getting started guide

Enabling Devices 5310 user guide

Enabling Devices

Enabling Devices 5310 user guide

Rompa 22259 manual

Rompa

Rompa 22259 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.